arXiv:2601.14876 · Physical Review Letters

Multiparameter estimation for the superresolution of two incoherent sources

Antonin Grateau, Alexander Boeschoten, Tanguy Favin-Lévêque, Isael Herrera, Nicolas Treps

quant-phSubmitted Jan 21, 2026• Announced Jan 22, 2026• 0 citations• Revised Jan 22, 2026 (v2)
v1 · Jan 21, 2026v2 · Jan 22, 2026
arXivHTMLPDF

Abstract

We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.

Related papers

Sub-Rayleigh Imaging of Unequal-Intensity Sources: Near-Quantum-Limit Multiparameter Estimation

Y. Batuhan Yilmaz, Kent A. G. Bonsma-Fisher, Muhammad Mohid +3 more

In optical imaging, diffraction strongly degrades the performance of conventional intensity-based estimation once the separation between two sources is below the Rayleigh-Abbe limit. Recent developments showed that this limitation can be surpassed using spatial-mode demultiplexing (SPADE), and this was demonstrated in several experiments for two equal-intensity spots of unknown separation. When there are multiple unknown parameters, as in the case of several unequal sources with unknown intensities and unknown separation, cross-talk among the parameters makes the multi-parameter estimation problem significantly more challenging. In this paper, we adapt super-resolved position localization by inversion of coherence along an edge (SPLICE) to estimate both the separation and relative intensity of two incoherent sources simultaneously. We demonstrate a clear advantage over direct imaging (DI), achieving a root mean squared error (RMSE) approximately $50 \%$ larger than the quantum limit and a sixfold improvement over DI within the range of parameters we tested. This improvement can be even greater for smaller separations and larger intensity imbalances when crosstalk is suppressed.

physics.opticsCross-listedarXiv:2608.07868•Aug 11, 2026•0 citations

Parameter estimation approach to super resolution

Alexander Boeschoten, Antonin Grateau, Clémentine Rouvière +7 more

The resolution of optical systems, formulated as the smallest possible distance between two point sources for which they still can be dissolved, was for a long time believed to be limited by diffraction, formulated by the Rayleigh criterion. Recent advancements in quantum metrology have shown, by evaluation of the Quantum Cramér Rao bound (QCRB), that the Rayleigh criterion is not a fundamental limit. In our experiment, spatial mode demultiplexing (SPADE) is used to estimate the separation of the sources orders of magnitude below the Rayleigh limit. The experiment is extended to incorporate the measurement of additional parameters, such as power imbalance and centroid position of the two sources, bringing it closer to real-world applicability.

SPIE Quantum Technologies for Defence and Security•Nov 15, 2024•0 citations

Superresolution in separation estimation between two dynamic incoherent sources using spatial demultiplexing

Konrad Schlichtholz, Łukasz Rudnicki

Abstract Achieving resolution in the sub-Rayleigh regime (superresolution) is one of the rapidly developing topics in quantum optics and metrology. Recently, it was shown that perfect measurement based on spatial mode demultiplexing (SPADE) in Hermite–Gauss modes allows one to reach the quantum limit of precision for estimation of separation between two weak incoherent stationary sources. Since then, different imperfections such as misalignment or crosstalk between modes have been studied to check how this result translates into more realistic experimental setups. In this paper, we consider another deviation from the perfect setup by discarding the assumption about the stationarity of the sources. This is relevant for example for astrophysical applications where planets necessarily orbit around the star. We analyze two examples of dynamics: rotations and oscillations, showing the robustness of the SPADE-based measurement against them. The analysis is based on Fisher information, which allows one to obtain the precision limit through Cramér–Rao bound. Furthermore, we formulate a measurement algorithm that allows for the reduction of one parameter for estimation (system orientation angle) in the stationary sources scenario, maintaining the measurement precision despite the lack of knowledge about this parameter.

arXiv:2407.10507•New Journal of Physics•Nov 14, 2024•4 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•169 citations

Spatial mode demultiplexing for super-resolved source parameter estimation

John S. Wallis, David R. Gozzard, Alex M. Frost +3 more

We present the use of a multi-planar light converter (MPLC) to perform spatial mode demultiplexing (SPADE) for optical source parameter estimation. This technique has been extended to use higher-order Hermite-Gaussian modes for the purposes of estimating the separation of a pair of incoherent sources, both above and below the diffraction limit. We resolve these sources at separations 90× lower than the diffraction limit. We also show our system is capable of simultaneous separation estimation and relative power estimation while maintaining super-resolving capabilities, with relative power differences as large as 20 dB by using the additional information gained by incorporation of the higher order modes. These results support the potential use of SPADE for astronomical imaging of binary systems.

Optics Express•Jul 16, 2025•3 citations

Experimental Separation Estimation of Incoherent Optical Sources Reaching the Cramér-Rao Bound

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1]–[3]. Our experimental setup (see Fig. 1 (left)) allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•1 citation
We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.
In optical imaging, diffraction strongly degrades the performance of conventional intensity-based estimation once the separation between two sources is below the Rayleigh-Abbe limit. Recent developments showed that this limitation can be surpassed using spatial-mode demultiplexing (SPADE), and this was demonstrated in several experiments for two equal-intensity spots of unknown separation. When there are multiple unknown parameters, as in the case of several unequal sources with unknown intensities and unknown separation, cross-talk among the parameters makes the multi-parameter estimation problem significantly more challenging. In this paper, we adapt super-resolved position localization by inversion of coherence along an edge (SPLICE) to estimate both the separation and relative intensity of two incoherent sources simultaneously. We demonstrate a clear advantage over direct imaging (DI), achieving a root mean squared error (RMSE) approximately 50%50 \%50% larger than the quantum limit and a sixfold improvement over DI within the range of parameters we tested. This improvement can be even greater for smaller separations and larger intensity imbalances when crosstalk is suppressed.
The resolution of optical systems, formulated as the smallest possible distance between two point sources for which they still can be dissolved, was for a long time believed to be limited by diffraction, formulated by the Rayleigh criterion. Recent advancements in quantum metrology have shown, by evaluation of the Quantum Cramér Rao bound (QCRB), that the Rayleigh criterion is not a fundamental limit. In our experiment, spatial mode demultiplexing (SPADE) is used to estimate the separation of the sources orders of magnitude below the Rayleigh limit. The experiment is extended to incorporate the measurement of additional parameters, such as power imbalance and centroid position of the two sources, bringing it closer to real-world applicability.
Abstract Achieving resolution in the sub-Rayleigh regime (superresolution) is one of the rapidly developing topics in quantum optics and metrology. Recently, it was shown that perfect measurement based on spatial mode demultiplexing (SPADE) in Hermite–Gauss modes allows one to reach the quantum limit of precision for estimation of separation between two weak incoherent stationary sources. Since then, different imperfections such as misalignment or crosstalk between modes have been studied to check how this result translates into more realistic experimental setups. In this paper, we consider another deviation from the perfect setup by discarding the assumption about the stationarity of the sources. This is relevant for example for astrophysical applications where planets necessarily orbit around the star. We analyze two examples of dynamics: rotations and oscillations, showing the robustness of the SPADE-based measurement against them. The analysis is based on Fisher information, which allows one to obtain the precision limit through Cramér–Rao bound. Furthermore, we formulate a measurement algorithm that allows for the reduction of one parameter for estimation (system orientation angle) in the stationary sources scenario, maintaining the measurement precision despite the lack of knowledge about this parameter.
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
We present the use of a multi-planar light converter (MPLC) to perform spatial mode demultiplexing (SPADE) for optical source parameter estimation. This technique has been extended to use higher-order Hermite-Gaussian modes for the purposes of estimating the separation of a pair of incoherent sources, both above and below the diffraction limit. We resolve these sources at separations 90× lower than the diffraction limit. We also show our system is capable of simultaneous separation estimation and relative power estimation while maintaining super-resolving capabilities, with relative power differences as large as 20 dB by using the additional information gained by incorporation of the higher order modes. These results support the potential use of SPADE for astronomical imaging of binary systems.
Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1]–[3]. Our experimental setup (see Fig. 1 (left)) allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].