Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1606.08332

Achieving quantum-limited optical resolution

Martin Paùr, B. Stoklasa, Z. Hradil, Luis Lorenzo Sánchez-Soto, Jaroslav Řeháček

Published Jun 27, 2016• 5 citations
arXivHTMLPDF

Abstract

We establish a simple method to assess the quantum Fisher information required for resolving two incoherent point sources with an imaging system. The resulting Cramér-Rao bound shows that the standard Rayleigh limit can be surpassed by suitable coherent measurements. We explicitly find these optimal strategies and present a realization for Gaussian and slit apertures. This involves a projection onto the optimal bases that is accomplished with digital holographic techniques and is compared with a CCD position measurement. Our experimental results unequivocally confirm unprecedented sub-Rayleigh precision.

DOI
10.48550/arxiv.1606.08332

Related papers

Passive optical superresolution at the quantum limit

A. I. Lvovsky, Michael R. Grace, Saikat Guha +3 more

For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.

quant-pharXiv:2605.10767•Optica•May 12, 2026•0 citations

Ultimate quantum limit on resolution of two thermal point sources

Ranjith Nair, Mankei Tsang

We obtain the fundamental quantum limit for resolving two thermal point sources using an imaging system with limited spatial bandwidth. Using the quantum Cram\'er-Rao bound, we show that the standard Rayleigh limit is not fundamental and can be surpassed by concrete coherent measurement techniques. Our results are valid for all values of the source strength, all ranges of the electromagnetic spectrum, and for any imaging system with an inversion-symmetric point-spread function. Our findings have applications to many areas of metrology including microscopy, astronomy, and standoff target sensing.

•Apr 4, 2016•2 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•169 citations

Dispelling Rayleigh's Curse

Jaroslav Řeháček, Martin Paùr, B. Stoklasa +3 more

We devise a systematic method to determine the Fisher information required for resolving two incoherent point sources with a diffraction-limited linear imaging device. The resulting Cramér-Rao bound gives the lowest variance achievable for an unbiased estimator. When only intensity in the image plane is recorded, this bound diverges as the separation between the sources tends to zero, an effect which has been dubbed as Rayleigh's curse. However, this curse can be lifted using suitable coherent measurements. In particular, we determine a class of measurements that can be easily implemented as projections on the orthogonalised derivatives of the point spread function of the system.

arXiv:1607.05837•Jul 20, 2016•3 citations

Quantum limit for two-dimensional resolution of two incoherent optical point sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the $x$ and $y$ components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.

arXiv:1606.00603•Physical Review A•Jun 29, 2017•96 citations

Quantum Limit for Two-Dimensional Resolution of Two Incoherent Optical Point Sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the quantum Cramér-Rao (QCR) bound for estimating the 2-D separation of two incoherent optical point sources. The bound is independent of the x- and y-separations. We also propose an interferometric scheme that approaches the bound for sub-Rayleigh separations.

Conference on Lasers and Electro-Optics•Jan 1, 2016•2 citations
We establish a simple method to assess the quantum Fisher information required for resolving two incoherent point sources with an imaging system. The resulting Cramér-Rao bound shows that the standard Rayleigh limit can be surpassed by suitable coherent measurements. We explicitly find these optimal strategies and present a realization for Gaussian and slit apertures. This involves a projection onto the optimal bases that is accomplished with digital holographic techniques and is compared with a CCD position measurement. Our experimental results unequivocally confirm unprecedented sub-Rayleigh precision.
For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.
We obtain the fundamental quantum limit for resolving two thermal point sources using an imaging system with limited spatial bandwidth. Using the quantum Cram\'er-Rao bound, we show that the standard Rayleigh limit is not fundamental and can be surpassed by concrete coherent measurement techniques. Our results are valid for all values of the source strength, all ranges of the electromagnetic spectrum, and for any imaging system with an inversion-symmetric point-spread function. Our findings have applications to many areas of metrology including microscopy, astronomy, and standoff target sensing.
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
We devise a systematic method to determine the Fisher information required for resolving two incoherent point sources with a diffraction-limited linear imaging device. The resulting Cramér-Rao bound gives the lowest variance achievable for an unbiased estimator. When only intensity in the image plane is recorded, this bound diverges as the separation between the sources tends to zero, an effect which has been dubbed as Rayleigh's curse. However, this curse can be lifted using suitable coherent measurements. In particular, we determine a class of measurements that can be easily implemented as projections on the orthogonalised derivatives of the point spread function of the system.
We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the xxx and yyy components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.