Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Latin America Optics and Photonics Conference

Optical Super-Resolution at the Quantum Limit

Z. Hradil, Jaroslav Řeháček, B. Stoklasa, Martin Paùr, Jai Grover, A. Krzic, Luis Lorenzo Sánchez-Soto

Published Jan 1, 2018• 0 citations
Publisher

Abstract

We establish the multiparameter quantum Cramér-Rao bound (qCRB) for quantum inspired imaging of two incoherent point sources. Analysis of the ultimate bounds may pave the way for future practical applications in optical metrology.
DOI
10.1364/laop.2018.w3a.1

Related papers

Towards Realistic Superresolution of Incoherent Point Sources

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cramér-Rao bound for quantum inspired imaging of two incoherent point sources and discuss the optimal detection schemes achieving the ultimate precision predicted by quantum theory thus paving the way for future practical implementations.

Imaging and Applied Optics•Jan 1, 2018•0 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•169 citations

Passive optical superresolution at the quantum limit

A. I. Lvovsky, Michael R. Grace, Saikat Guha +3 more

For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.

quant-pharXiv:2605.10767•Optica•May 12, 2026•0 citations

Quantum-limited localization and resolution in three dimensions

Ben Wang, Liang Xu, Jun-chi Li +1 more

As a method to extract information from optical systems, imaging can be viewed as a parameter estimation problem. The fundamental precision in locating one emitter or estimating the separation between two incoherent emitters is bounded below by the multiparameter quantum Cramér-Rao bound (QCRB). Multiparameter QCRB gives an intrinsic bound in parameter estimation. We determine the ultimate potential of quantum-limited imaging for improving the resolution of a far-field, diffraction-limited optical field within the paraxial approximation. We show that the quantum Fisher information matrix (QFIm) in about one emitter’s position is independent on its true value. We calculate the QFIm of two unequal-brightness emitters’ relative positions and intensities; the results show that only when the relative intensity and centroids of two-point sources, including longitudinal and transverse directions, are known exactly, the separation in different directions can be estimated simultaneously with finite precision. Our results give the upper bounds on certain far-field imaging technology and will find wide use in applications from microscopy to astrometry.

arXiv:2012.05089•Photonics Research•Jun 9, 2021•19 citations

Quantum Limit for Two-Dimensional Resolution of Two Incoherent Optical Point Sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the quantum Cramér-Rao (QCR) bound for estimating the 2-D separation of two incoherent optical point sources. The bound is independent of the x- and y-separations. We also propose an interferometric scheme that approaches the bound for sub-Rayleigh separations.

Conference on Lasers and Electro-Optics•Jan 1, 2016•2 citations

Conservative classical and quantum resolution limits for incoherent imaging

Mankei Tsang

I propose classical and quantum limits to the statistical resolution of two incoherent optical point sources from the perspective of minimax parameter estimation. Unlike earlier results based on the Cramér-Rao bound (CRB), the limits proposed here, based on the worst-case error criterion and a Bayesian version of the CRB, are valid for any biased or unbiased estimator and obey photon-number scalings that are consistent with the behaviours of actual estimators. These results prove that, from the minimax perspective, the spatial-mode demultiplexing measurement scheme recently proposed by Tsang, Nair, and Lu [Phys. Rev. X 2016, 6 031033.] remains superior to direct imaging for sufficiently high photon numbers.

arXiv:1605.03799•Journal of Modern Optics•Sep 18, 2017•32 citations
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.
As a method to extract information from optical systems, imaging can be viewed as a parameter estimation problem. The fundamental precision in locating one emitter or estimating the separation between two incoherent emitters is bounded below by the multiparameter quantum Cramér-Rao bound (QCRB). Multiparameter QCRB gives an intrinsic bound in parameter estimation. We determine the ultimate potential of quantum-limited imaging for improving the resolution of a far-field, diffraction-limited optical field within the paraxial approximation. We show that the quantum Fisher information matrix (QFIm) in about one emitter’s position is independent on its true value. We calculate the QFIm of two unequal-brightness emitters’ relative positions and intensities; the results show that only when the relative intensity and centroids of two-point sources, including longitudinal and transverse directions, are known exactly, the separation in different directions can be estimated simultaneously with finite precision. Our results give the upper bounds on certain far-field imaging technology and will find wide use in applications from microscopy to astrometry.
I propose classical and quantum limits to the statistical resolution of two incoherent optical point sources from the perspective of minimax parameter estimation. Unlike earlier results based on the Cramér-Rao bound (CRB), the limits proposed here, based on the worst-case error criterion and a Bayesian version of the CRB, are valid for any biased or unbiased estimator and obey photon-number scalings that are consistent with the behaviours of actual estimators. These results prove that, from the minimax perspective, the spatial-mode demultiplexing measurement scheme recently proposed by Tsang, Nair, and Lu [Phys. Rev. X 2016, 6 031033.] remains superior to direct imaging for sufficiently high photon numbers.