Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2012.05089 · Photonics Research

Quantum-limited localization and resolution in three dimensions

Ben Wang, Liang Xu, Jun-chi Li, Lijian Zhang

Published Jun 9, 2021• 19 citations
arXivHTMLPDF

Abstract

As a method to extract information from optical systems, imaging can be viewed as a parameter estimation problem. The fundamental precision in locating one emitter or estimating the separation between two incoherent emitters is bounded below by the multiparameter quantum Cramér-Rao bound (QCRB). Multiparameter QCRB gives an intrinsic bound in parameter estimation. We determine the ultimate potential of quantum-limited imaging for improving the resolution of a far-field, diffraction-limited optical field within the paraxial approximation. We show that the quantum Fisher information matrix (QFIm) in about one emitter’s position is independent on its true value. We calculate the QFIm of two unequal-brightness emitters’ relative positions and intensities; the results show that only when the relative intensity and centroids of two-point sources, including longitudinal and transverse directions, are known exactly, the separation in different directions can be estimated simultaneously with finite precision. Our results give the upper bounds on certain far-field imaging technology and will find wide use in applications from microscopy to astrometry.

DOI
10.1364/prj.417613

Related papers

Fundamental Precision Bounds for Three-Dimensional Optical Localization Microscopy with Poisson Statistics

Mikael P. Backlund, Yoav Shechtman, Ronald Lee Walsworth

Point source localization is a problem of persistent interest in optical imaging. In particular, a number of widely used biological microscopy techniques rely on precise three-dimensional localization of single fluorophores. As emitter depth localization is more challenging than lateral localization, considerable effort has been spent on engineering the response of the microscope in a way that reveals increased depth information. Here, we prove the (sub)optimality of these approaches by deriving and comparing to the measurement-independent quantum Cramér-Rao bound (QCRB). We show that existing methods for depth localization with single-objective collection exceed the QCRB, and we gain insight into the bound by proposing an interferometer arrangement that approaches it. We also show that for light collection with two opposed objectives, an established interferometric technique globally reaches the QCRB in all three dimensions simultaneously, and so this represents an interesting case study from the point of view of quantum multiparameter estimation.

arXiv:1803.01776•Physical Review Letters•Jul 11, 2018•68 citations

Optical Super-Resolution at the Quantum Limit

Z. Hradil, Jaroslav Řeháček, B. Stoklasa +4 more

We establish the multiparameter quantum Cramér-Rao bound (qCRB) for quantum inspired imaging of two incoherent point sources. Analysis of the ultimate bounds may pave the way for future practical applications in optical metrology.

Latin America Optics and Photonics Conference•Jan 1, 2018•0 citations

Quantifying classical and quantum bounds for resolving closely spaced, non-interacting, simultaneously emitting dipole sources in optical microscopy

Armine I. Dingilian, Aarnah Kurella, Cheyenne S. Mitchell +3 more

Recent theoretical and experimental work has shown that the quantum Fisher information associated with estimating the separation between two optical point sources remains finite at small separations, effectively opening new routes to super-resolution imaging of simultaneously emitting sources. Most studies to date, however, implicitly invoke the scalar approximation, which is not appropriate in the context of high-numerical-aperture microscopy. Utilizing parameter estimation theory, here we consider the estimation of separation between two closely spaced dipole emitters, a commonly employed model for single-molecule optical beacons. We consider two limiting cases: one in which the orientations of the emitters are fixed and equal, and another in which both dipoles freely sample all of orientation space over the course of the measurement. We quantify precision limits using quantum and classical variants of the Fisher information and Cramér-Rao bound. In all cases, the vectorial nature of the emission complicates the analyses, but with appropriate filtering of the collected light in the azimuthal-radial polarization basis, a previously proposed scheme to saturate the quantum Fisher information via image inversion interferometry can be salvaged.

quant-pharXiv:2512.10889•The Journal of Chemical Physics•Dec 12, 2025•0 citations

Attaining Fundamental Limits of Multiparameter Incoherent Optical Imaging Using Joint-Detection Quantum Measurements

Nico Deshler, Aakash Warke, Michael R. Grace +2 more

Resolving extended incoherent objects below the diffraction limit poses an application-rich imaging challenge whose solution may enable a new generation of observational instruments and capabilities. In this work, we invoke a practical model for general imaging by approximating an arbitrary extended incoherent object as a finite grid of thermal point emitters parameterized by their brightnesses. We derive the quantum Fisher information matrix (QFIM) for simultaneous brightness estimation and show that the symmetric logarithmic derivatives weakly commute, indicating that the Helstrom bound furnishes the ultimate quantum limit on the estimation error for incoherent imaging. Furthermore, for deeply sub-diffraction scenes, we find numerical evidence of a gap between the Nagaoka-Hayashi (NH) bound and the Helstrom bound. This gap reveals that separable measurements, though more experimentally accessible, are insufficient to reach the quantum limit, and points to the prospective advantage of joint measurements acting on multiple state copies. Additionally, we show that spatial mode-demultiplexing (SPADE) often saturates the NH bound solidifying its status as a near-optimal separable measurement strategy that significantly outperforms direct imaging. Finally, we articulate two joint detection receivers implemented with bona fide quantum resources that asymptotically achieve the Helstrom bound.

quant-pharXiv:2608.19524•Aug 21, 2026•0 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•169 citations

Passive optical superresolution at the quantum limit

A. I. Lvovsky, Michael R. Grace, Saikat Guha +3 more

For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.

quant-pharXiv:2605.10767•Optica•May 12, 2026•0 citations
As a method to extract information from optical systems, imaging can be viewed as a parameter estimation problem. The fundamental precision in locating one emitter or estimating the separation between two incoherent emitters is bounded below by the multiparameter quantum Cramér-Rao bound (QCRB). Multiparameter QCRB gives an intrinsic bound in parameter estimation. We determine the ultimate potential of quantum-limited imaging for improving the resolution of a far-field, diffraction-limited optical field within the paraxial approximation. We show that the quantum Fisher information matrix (QFIm) in about one emitter’s position is independent on its true value. We calculate the QFIm of two unequal-brightness emitters’ relative positions and intensities; the results show that only when the relative intensity and centroids of two-point sources, including longitudinal and transverse directions, are known exactly, the separation in different directions can be estimated simultaneously with finite precision. Our results give the upper bounds on certain far-field imaging technology and will find wide use in applications from microscopy to astrometry.
Point source localization is a problem of persistent interest in optical imaging. In particular, a number of widely used biological microscopy techniques rely on precise three-dimensional localization of single fluorophores. As emitter depth localization is more challenging than lateral localization, considerable effort has been spent on engineering the response of the microscope in a way that reveals increased depth information. Here, we prove the (sub)optimality of these approaches by deriving and comparing to the measurement-independent quantum Cramér-Rao bound (QCRB). We show that existing methods for depth localization with single-objective collection exceed the QCRB, and we gain insight into the bound by proposing an interferometer arrangement that approaches it. We also show that for light collection with two opposed objectives, an established interferometric technique globally reaches the QCRB in all three dimensions simultaneously, and so this represents an interesting case study from the point of view of quantum multiparameter estimation.
Recent theoretical and experimental work has shown that the quantum Fisher information associated with estimating the separation between two optical point sources remains finite at small separations, effectively opening new routes to super-resolution imaging of simultaneously emitting sources. Most studies to date, however, implicitly invoke the scalar approximation, which is not appropriate in the context of high-numerical-aperture microscopy. Utilizing parameter estimation theory, here we consider the estimation of separation between two closely spaced dipole emitters, a commonly employed model for single-molecule optical beacons. We consider two limiting cases: one in which the orientations of the emitters are fixed and equal, and another in which both dipoles freely sample all of orientation space over the course of the measurement. We quantify precision limits using quantum and classical variants of the Fisher information and Cramér-Rao bound. In all cases, the vectorial nature of the emission complicates the analyses, but with appropriate filtering of the collected light in the azimuthal-radial polarization basis, a previously proposed scheme to saturate the quantum Fisher information via image inversion interferometry can be salvaged.
Resolving extended incoherent objects below the diffraction limit poses an application-rich imaging challenge whose solution may enable a new generation of observational instruments and capabilities. In this work, we invoke a practical model for general imaging by approximating an arbitrary extended incoherent object as a finite grid of thermal point emitters parameterized by their brightnesses. We derive the quantum Fisher information matrix (QFIM) for simultaneous brightness estimation and show that the symmetric logarithmic derivatives weakly commute, indicating that the Helstrom bound furnishes the ultimate quantum limit on the estimation error for incoherent imaging. Furthermore, for deeply sub-diffraction scenes, we find numerical evidence of a gap between the Nagaoka-Hayashi (NH) bound and the Helstrom bound. This gap reveals that separable measurements, though more experimentally accessible, are insufficient to reach the quantum limit, and points to the prospective advantage of joint measurements acting on multiple state copies. Additionally, we show that spatial mode-demultiplexing (SPADE) often saturates the NH bound solidifying its status as a near-optimal separable measurement strategy that significantly outperforms direct imaging. Finally, we articulate two joint detection receivers implemented with bona fide quantum resources that asymptotically achieve the Helstrom bound.
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.