Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of the IEICE General Conference

A New Structure of Coplanar-Waveguide Superconducting Resonator for Improving Power Handling Capability

Kei Satoh, Daisuke Koizumi, Shoichi Narahashi

Published Mar 7, 2005• 0 citations
OpenAlex

Related papers

Superconducting Coplanar Waveguide Resonators Capable of Cofabrication with Josephson Junctions

Yingshan Zhang, Jianshe Liu, Changhao Zhao +2 more

Journal of Superconductivity and Novel Magnetism•Jan 14, 2019•1 citation

Power Handling and Responsivity of Submicron Wide Superconducting Coplanar Waveguide Resonators

R. M. J. Janssen, Akira Endo, J. J. A. Baselmans +3 more

The sensitivity of microwave kinetic inductance detectors (MKIDs) based on coplanar waveguides (CPWs) needs to be improved by at least an order of magnitude to satisfy the requirements for space-based terahertz astronomy. Our aim is to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (>1 μm). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. In a systematic study of quarter-wave CPW resonators with varying widths it is shown that the behavior of responsivity, noise and power handling as a function of width continues down to 300 nm. This encourages the development of narrow KIDs using Al in order to improve their sensitivity.

arXiv:1206.0579•Journal of Low Temperature Physics•Jan 20, 2012•7 citations

Fabrication and characterization of magnetic-field-resilient MoRe superconducting coplanar waveguide resonators

Chang Geun Yu, Bongkeon Kim, Yong‐Joo Doh

arXiv:2211.16948•Current Applied Physics•Dec 31, 2022•4 citations

Thermal-sensitive superconducting coplanar waveguide resonator used for weak light detection

Pin-Jia Zhou, Yiwen Wang, Lian-Fu Wei

Since the last decades, superconducting single-photon technology has been extensively used in the quantum security communication and the linear-optic quantum computing fields. Especially, the device based on the coplanar waveguide resonator has attracted substantial interests due to its evident advantages, including the relatively simple structure, the sufficiently high detection efficiency, and the photon-resolving capability, etc. With the profound investigation in optimizing the depositing methods and the material selections, as well as the the development of the relevant theories, the technology of single photon detection based on the coplanar waveguide resonator has obtained a breakthrough. In this review paper we begin from the basic principle of the coplanar waveguide detector, then interpret the relevant theory and some design details of the devices. Finally, based on some of the recent experimental results measured with the low-temperature devices in our lab, we give a brief perspective on the future development of the superconducting coplanar waveguide single photon detectors.

Acta Physica Sinica•Jan 1, 2014•5 citations

Submicron Kinetic Inductance Detectors for SAFARI: Improving MKID sensitivity through width reduction

R. M. J. Janssen

Spectroscopic observations of a large number of galaxies in the far-infrared are critical in the study of galaxy evolution. These observations are difficult at the moment, because of the lack of good far-infrared (FIR) detector technology. Microwave Kinetic Inductance Detectors (MKIDs) are showing promising results to fill this void. A common MKID design is the antenna-coupled coplanar waveguide (CPW) resonator patterned in a superconducting film. These resonators are extremely sensitive to changes in the Cooper pair density. FIR photons are energetic enough to break Cooper pairs. This means a superconducting resonator can be used as a pixel for a FIR camera. The inherent multiplexing advantage of MKIDs means they can easily be fabricated in arrays of up to 5000 pixels. By putting such an array in the SAFARI instrument on the cooled SPICA telescope a blind spectroscopic survey that can detect Milky Way sized galaxies out to redshift z = 2 will be possible. However, to achieve background limited performance on a cooled telescope like SPICA the sensivity of MKIDs needs to be improved by at least an order of magnitude. This project aims to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (> 1 ?m). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. Using this fabrication method NbTiN resonators with a central line width varying between 0.3 ?m and 3 ?m were made. These resonators were used to do a systematic study of the width dependence of the kinetic inductance fraction, quality factor, responsivity, read-out power, noise and NEP. It is shown that the width dependence of all these properties does not change down to 300 nm. Encouraged by these results two prototype submicron pixel arrays were made in aluminum. These showed sensitivities comparable to resonators with a few micron wide CPW. The main reason for this lack of sensitivity improvement is the lower maximum read-out power of submicron wide aluminum resonators. Based on these results power handling seems a key issue that will determine if submicron resonators are a viable route to improve the MKIDs sensitivity. These results of this project indicate that aluminum has a different width dependence of its power handling compared to NbTiN. Therefore, a systematic study of submicron resonators in aluminum, which focuses on the power handling, is required.

•Dec 10, 2010•2 citations

Integrated Superconducting Coplanar Waveguide Resonators for Quantum Computing Applications

Daniel Rocha-Aguilera, Gabriela Méndez‐Jerónimo, Joel Molina Reyes

•Jan 1, 2025•0 citations
The sensitivity of microwave kinetic inductance detectors (MKIDs) based on coplanar waveguides (CPWs) needs to be improved by at least an order of magnitude to satisfy the requirements for space-based terahertz astronomy. Our aim is to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (>1 μm). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. In a systematic study of quarter-wave CPW resonators with varying widths it is shown that the behavior of responsivity, noise and power handling as a function of width continues down to 300 nm. This encourages the development of narrow KIDs using Al in order to improve their sensitivity.
Since the last decades, superconducting single-photon technology has been extensively used in the quantum security communication and the linear-optic quantum computing fields. Especially, the device based on the coplanar waveguide resonator has attracted substantial interests due to its evident advantages, including the relatively simple structure, the sufficiently high detection efficiency, and the photon-resolving capability, etc. With the profound investigation in optimizing the depositing methods and the material selections, as well as the the development of the relevant theories, the technology of single photon detection based on the coplanar waveguide resonator has obtained a breakthrough. In this review paper we begin from the basic principle of the coplanar waveguide detector, then interpret the relevant theory and some design details of the devices. Finally, based on some of the recent experimental results measured with the low-temperature devices in our lab, we give a brief perspective on the future development of the superconducting coplanar waveguide single photon detectors.
Spectroscopic observations of a large number of galaxies in the far-infrared are critical in the study of galaxy evolution. These observations are difficult at the moment, because of the lack of good far-infrared (FIR) detector technology. Microwave Kinetic Inductance Detectors (MKIDs) are showing promising results to fill this void. A common MKID design is the antenna-coupled coplanar waveguide (CPW) resonator patterned in a superconducting film. These resonators are extremely sensitive to changes in the Cooper pair density. FIR photons are energetic enough to break Cooper pairs. This means a superconducting resonator can be used as a pixel for a FIR camera. The inherent multiplexing advantage of MKIDs means they can easily be fabricated in arrays of up to 5000 pixels. By putting such an array in the SAFARI instrument on the cooled SPICA telescope a blind spectroscopic survey that can detect Milky Way sized galaxies out to redshift z = 2 will be possible. However, to achieve background limited performance on a cooled telescope like SPICA the sensivity of MKIDs needs to be improved by at least an order of magnitude. This project aims to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (> 1 ?m). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. Using this fabrication method NbTiN resonators with a central line width varying between 0.3 ?m and 3 ?m were made. These resonators were used to do a systematic study of the width dependence of the kinetic inductance fraction, quality factor, responsivity, read-out power, noise and NEP. It is shown that the width dependence of all these properties does not change down to 300 nm. Encouraged by these results two prototype submicron pixel arrays were made in aluminum. These showed sensitivities comparable to resonators with a few micron wide CPW. The main reason for this lack of sensitivity improvement is the lower maximum read-out power of submicron wide aluminum resonators. Based on these results power handling seems a key issue that will determine if submicron resonators are a viable route to improve the MKIDs sensitivity. These results of this project indicate that aluminum has a different width dependence of its power handling compared to NbTiN. Therefore, a systematic study of submicron resonators in aluminum, which focuses on the power handling, is required.