Spectroscopic observations of a large number of galaxies in the far-infrared are critical in the study of galaxy evolution. These observations are difficult at the moment, because of the lack of good far-infrared (FIR) detector technology. Microwave Kinetic Inductance Detectors (MKIDs) are showing promising results to fill this void. A common MKID design is the antenna-coupled coplanar waveguide (CPW) resonator patterned in a superconducting film. These resonators are extremely sensitive to changes in the Cooper pair density. FIR photons are energetic enough to break Cooper pairs. This means a superconducting resonator can be used as a pixel for a FIR camera. The inherent multiplexing advantage of MKIDs means they can easily be fabricated in arrays of up to 5000 pixels. By putting such an array in the SAFARI instrument on the cooled SPICA telescope a blind spectroscopic survey that can detect Milky Way sized galaxies out to redshift z = 2 will be possible. However, to achieve background limited performance on a cooled telescope like SPICA the sensivity of MKIDs needs to be improved by at least an order of magnitude. This project aims to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (> 1 ?m). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. Using this fabrication method NbTiN resonators with a central line width varying between 0.3 ?m and 3 ?m were made. These resonators were used to do a systematic study of the width dependence of the kinetic inductance fraction, quality factor, responsivity, read-out power, noise and NEP. It is shown that the width dependence of all these properties does not change down to 300 nm. Encouraged by these results two prototype submicron pixel arrays were made in aluminum. These showed sensitivities comparable to resonators with a few micron wide CPW. The main reason for this lack of sensitivity improvement is the lower maximum read-out power of submicron wide aluminum resonators. Based on these results power handling seems a key issue that will determine if submicron resonators are a viable route to improve the MKIDs sensitivity. These results of this project indicate that aluminum has a different width dependence of its power handling compared to NbTiN. Therefore, a systematic study of submicron resonators in aluminum, which focuses on the power handling, is required.
Spectroscopic observations of a large number of galaxies in the far-infrared are critical in the study of galaxy evolution. These observations are difficult at the moment, because of the lack of good far-infrared (FIR) detector technology. Microwave Kinetic Inductance Detectors (MKIDs) are showing promising results to fill this void. A common MKID design is the antenna-coupled coplanar waveguide (CPW) resonator patterned in a superconducting film. These resonators are extremely sensitive to changes in the Cooper pair density. FIR photons are energetic enough to break Cooper pairs. This means a superconducting resonator can be used as a pixel for a FIR camera. The inherent multiplexing advantage of MKIDs means they can easily be fabricated in arrays of up to 5000 pixels. By putting such an array in the SAFARI instrument on the cooled SPICA telescope a blind spectroscopic survey that can detect Milky Way sized galaxies out to redshift z = 2 will be possible. However, to achieve background limited performance on a cooled telescope like SPICA the sensivity of MKIDs needs to be improved by at least an order of magnitude. This project aims to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (> 1 ?m). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. Using this fabrication method NbTiN resonators with a central line width varying between 0.3 ?m and 3 ?m were made. These resonators were used to do a systematic study of the width dependence of the kinetic inductance fraction, quality factor, responsivity, read-out power, noise and NEP. It is shown that the width dependence of all these properties does not change down to 300 nm. Encouraged by these results two prototype submicron pixel arrays were made in aluminum. These showed sensitivities comparable to resonators with a few micron wide CPW. The main reason for this lack of sensitivity improvement is the lower maximum read-out power of submicron wide aluminum resonators. Based on these results power handling seems a key issue that will determine if submicron resonators are a viable route to improve the MKIDs sensitivity. These results of this project indicate that aluminum has a different width dependence of its power handling compared to NbTiN. Therefore, a systematic study of submicron resonators in aluminum, which focuses on the power handling, is required.
The sensitivity of microwave kinetic inductance detectors (MKIDs) based on coplanar waveguides (CPWs) needs to be improved by at least an order of magnitude to satisfy the requirements for space-based terahertz astronomy. Our aim is to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (>1 μm). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. In a systematic study of quarter-wave CPW resonators with varying widths it is shown that the behavior of responsivity, noise and power handling as a function of width continues down to 300 nm. This encourages the development of narrow KIDs using Al in order to improve their sensitivity.
We present results from completely lithographic antenna-coupled Microwave Kinetic Inductance detectors (MKIDs). MKIDs are superconducting resonators with resonant frequency and quality-factor which are highly sensitive to changes in the density of the quasiparticle population which occurs when photons above the superconducting gap energy are absorbed. The resonators are coupled to submm light through on-chip phased-array slot antennas. Each planar antenna consists of an array of N long slots which are fed along their length at M points. The resulting N*M feed points are combined in-phase using a binary summing tree made of low-loss superconducting microstrip lines. Due to its large size, the resulting planar antenna produces a narrow beam pattern and can therefore be used without additional optical coupling elements such as feedhorns or substrate lenses. The output of the antenna is a single superconducting thin-film microstrip line which can be efficiently coupled to one (or more) kinetic inductance coplanar waveguide resonators to produce a single (or multi-color) pixel in an imaging focal plane array, using in-line lumped element lithographic band-pass filters. Such highly integrated architectures can be easily fabricated on a single substrate, and many detectors can be frequency multiplexed through coupling to a single feedline. Microwave readout provides a lot of bandwidth per detector, allowing a large number of pixels to be read using a single cryogenic microwave amplifier and warm readout electronics.
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting microresonators useful as detectors for sub/millimeter and far-infrared cameras, as well as instruments in optical and x-ray wavelengths. A probe sine wave at the resonance frequency can detect a change in frequency and microwave loss due to submillimeter optical load as a phase or amplitude change. These detectors may be coupled to light through on-chip, phased-array antennas. A single antenna may feed several detectors with different bandpasses defined by on-chip lumped-element filters. The resonators are easily frequency multiplexed by tuning the resonance frequencies, so hundreds of detectors can be read out while coupled to a single feedline. The deployment and operation of ground-based, background-limited detectors in close-packed arrays present significant challenges in both readout strategy and array design. The initial designs consisted of simple coplanar waveguide microwave resonators with aluminum absorptive sections. The first change has been to substitute the capacitive portion of the resonator with a large interdigitated capacitor (IDC) to reduce its noise contribution. While their low-noise characteristics have been demonstrated, these detectors had not yet been tested on array-scale devices. We present results from arrays of detectors designed for sub/millimeter imaging, tested for their optical response characteristics. In particular, we address challenges of microwave inter-resonator coupling, out-of-band resonator optical sensitivity, and noise reduction in the latest device designs. We show the results of stepped-impedance filters in preventing direct pickup of wide-band radiation, and new frequency spacing to limit crosstalk between resonators. We show direct comparison between olderdesign coplanar waveguide resonators and new IDC resonators under optical load, demonstrating the noise reduction and comparable responsivity. In addition, we show results of the probe signal readout power that maximizes signal-to-noise.
Superconducting microwave resonators have the potential to revolutionize submillimeter and far-infrared astronomy, and with it our understanding of the universe. The field of low-temperature detector technology has reached a point where extremely sensitive devices like transition-edge sensors are now capable of detecting radiation limited by the background noise of the universe. However, the size of these detector arrays are limited to only a few thousand pixels. This is because of the cost and complexity of fabricating large-scale arrays of these detectors that can reach up to 10 lithographic levels on chip, and the complicated SQUID-based multiplexing circuitry and wiring for readout of each detector. In order to make substantial progress, next- generation ground-based telescopes such as CCAT or future space telescopes require focal planes with large-scale detector arrays of 104–106 pixels. Arrays using microwave kinetic inductance detectors (MKID) are a potential solution. These arrays can be easily made with a single layer of superconducting metal film deposited on a silicon substrate and pattered using conventional optical lithography. Furthermore, MKIDs are inherently multiplexable in the frequency domain, allowing ∼ 103 detectors to be read out using a single coaxial transmission line and cryogenic amplifier, drastically reducing cost and complexity. An MKID uses the change in the microwave surface impedance of a superconducting thin-film microresonator to detect photons. Absorption of photons in the superconductor breaks Cooper pairs into quasiparticles, changing the complex surface impedance, which results in a perturbation of resonator frequency and quality factor. For excitation and readout, the resonator is weakly coupled to a transmission line. The complex amplitude of a microwave probe signal tuned on-resonance and transmitted on the feedline past the resonator is perturbed as photons are absorbed in the superconductor. The perturbation can be detected using a cryogenic amplifier and subsequent homodyne mixing at room temperature. In an array of MKIDs, all the resonators are coupled to a shared feedline and are tuned to slightly different frequencies. They can be read out simultaneously using a comb of frequencies generated and measured using digital techniques. This thesis documents an effort to demonstrate the basic operation of ∼ 256 pixel arrays of lumped-element MKIDs made from superconducting TiNx on silicon. The resonators are designed and simulated for optimum operation. Various properties of the resonators and arrays are measured and compared to theoretical expectations. A particularly exciting observation is the extremely high quality factors (∼ 3 × 107) of our TiNx resonators which is essential for ultra-high sensitivity. The arrays are tightly packed both in space and in frequency which is desirable for larger full-size arrays. However, this can cause a serious problem in terms of microwave crosstalk between neighboring pixels. We show that by properly designing the resonator geometry, crosstalk can be eliminated; this is supported by our measurement results. We also tackle the problem of excess frequency noise in MKIDs. Intrinsic noise in the form of an excess resonance frequency jitter exists in planar superconducting resonators that are made on dielectric substrates. We conclusively show that this noise is due to fluctuations of the resonator capacitance. In turn, the capacitance fluctuations are thought to be driven by two-level system (TLS) fluctuators in a thin layer on the surface of the device. With a modified resonator design we demonstrate with measurements that this noise can be substantially reduced. An optimized version of this resonator was designed for the multiwavelength submillimeter kinetic inductance camera (MUSIC) instrument for the Caltech Submillimeter Observatory.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
Microwave Kinetic Inductance Detectors (MKIDs) are extremely sensitive radiation detectors based on superconducting resonators that can be combined in large arrays on a single readout line within a limited frequency bandwidth. This makes MKIDs ideal detectors for the ultimate far-infrared observatory: a future space-based actively cooled telescope with its performance solely limited by the low universe background radiation. However, to reach these detector requirements, state-of-the-art MKIDs still need a order of magnitude improvement in device sensitivity. In this work, the MKID sensitivity is improved by reducing the aluminium volume that absorbs pair-breaking radiation into quasiparticle excitations, while making sure all radiation is still absorbed. Furthermore, a key requirement is sufficient reduction of excess noise as to keep the device intrinsically limited by thermally driven random fluctuations in the number of quasiparticles in absence of radiation, or Generation-Recombination (G-R) noise. To this end, a model is developed that describes the noise contributions as function of device geometry, readout power, material properties and radiation power. Subsequently, a realistic MKID design is presented and tested that reduces excess noise and maximises the sensitivity, expressed as Noise Equivalent Power (NEP). At high temperatures, good overall agreement is found between the measured noise spectra and the model. At low temperature T = 120 mK, the measurement results give an optical NEP similar to current state-of-the-art MKIDs. The NEP is not as low as expected due to short quasiparticle lifetimes, an unexpected decrease in the G-R noise level and a very high excess noise attributed to Two-Level Systems (TLS) noise that starts to dominate the already low G-R noise spectrum at low temperatures. Possibly, the quick quasiparticle lifetime saturation and noise level drop are caused by a strong readout power effect, as the readout power is known to create excess quasiparticles and to cause a strongly non-thermal electron energy distribution in the aluminium strip of the MKID. However, the exact microscopic details of these effects are unknown and not studied in this project. Based on the current chip design, a straightforward way to improve device performance and study the readout power effect in more detail is a reduction of the high TLS noise levels, which is possibly fabrication related. This would allow an unobstructed view of the G-R noise spectrum at low temperatures, thereby allowing both a study of the readout power effect on the quasiparticle system, and ultimately achieving the improvement in NEP needed reach the detector requirements for the ultimate space-based far-infrared observatory.