We report on coplanar waveguides (CPWs) designed for optically detected magnetic resonance of nitrogen-vacancy (NV) centers in diamonds. A broad band up to 15.8 GHz has been realized, which ensures that the electron spins can be manipulated under external magnetic fields up to 5000 G. The conversion factor of CPW has been measured by Rabi nutation experiments, which ranges from 6.64 G W−1/2 to 10.60 G W−1/2 in the frequency band from 0.76 GHz to 17.3 GHz. Broadband CPWs also provide high quality control pulses due to the minimization of the distortion. These characteristics will find potential applications in NV-based quantum information processing and single spin magnetometry.
We report on coplanar waveguides (CPWs) designed for optically detected magnetic resonance of nitrogen-vacancy (NV) centers in diamonds. A broad band up to 15.8 GHz has been realized, which ensures that the electron spins can be manipulated under external magnetic fields up to 5000 G. The conversion factor of CPW has been measured by Rabi nutation experiments, which ranges from 6.64 G W−1/2 to 10.60 G W−1/2 in the frequency band from 0.76 GHz to 17.3 GHz. Broadband CPWs also provide high quality control pulses due to the minimization of the distortion. These characteristics will find potential applications in NV-based quantum information processing and single spin magnetometry.
Nitrogen-vacancy (NV) centers in diamond have emerged as promising quantum sensors due to their highly coherent and optically addressable spin states with potential applications in high-sensitivity magnetometry. Homogeneously addressing large ensembles of NV centers offers clear benefit in terms of sensing precision as well as in fundamental studies of collective effects. Such experiments require a spatially uniform, intense, and broadband microwave field that can be difficult to generate. Previous approaches, such as copper wires, loop coils, and planar structures, have shown limitations in field homogeneity, bandwidth, and integration in compact devices. In this paper, we present a coplanar waveguide (CPW) gold coil patterned on a 3 × 3 mm 2 diamond substrate, offering full integration, enhanced stability, and broad bandwidth suitable for various NV sensing applications. Coil fabricated on diamond offers several advantages for magnetometry with NV centers ensemble, including enhanced heat dissipation, seamless integration, scalability, and miniaturization potential. We optimize critical geometrical parameters to achieve a homogeneous magnetic field with a coefficient of variation of less than 6% over an area of 0.5 mm 2 and present experimental results confirming the performance of the proposed CPW coil.
The Nitrogen-Vacancy (NV) center in diamond is a prominent quantum system leveraged for advanced quantum metrology, particularly in high-precision magnetometry and high-resolution quantum imaging, exploiting the Optically Detected Magnetic Resonance (ODMR) spectroscopy technique. Proper radio-frequency (RF) excitation of NV centers is critical in order to manipulate these quantum states effectively. Our research focuses on optimizing the continuous-wave RF excitation of ensembles of NV centers on coplanar waveguide transmission lines (CPW-TL), measuring the centers' photoluminescence (PL) signal as a function of RF power. This setup enhances the sensitivity and resolution of the NV center PL signal. By combining CPW-TL lines with nanodiamonds, our approach aims to develop a scalable and tunable platform that can be deployed in a variety of quantum sensing scenarios, including in biomedical applications, navigation systems, environmental monitorlng, and beyond.
The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.
Nitrogen-Vacancy (NV) centers in diamond are attractive tools for sensing and quantum information. Realization of this potential requires effective tools for controlling the spin degree of freedom by microwave (mw) magnetic fields. In this work, we present a planar microwave resonator optimized for microwave-optical double resonance experiments on single NV centers in diamond. It consists of a piece of wide microstrip line, which is symmetrically connected to two 50 Ω microstrip feed lines. In the center of the resonator, an Ω-shaped loop focuses the current and the mw magnetic field. It generates a relatively homogeneous magnetic field over a volume of 0.07 × 0.1 mm3. It can be operated at 2.9 GHz in both transmission and reflection modes with bandwidths of 1000 and 400 MHz, respectively. The high power-to-magnetic field conversion efficiency allows us to produce π-pulses with a duration of 50 ns with only about 200 and 50 mW microwave power in transmission and reflection, respectively. The transmission mode also offers capability for efficient radio frequency excitation. The resonance frequency can be tuned between 1.3 and 6 GHz by adjusting the length of the resonator. This will be useful for experiments on NV-centers at higher external magnetic fields and on different types of optically active spin centers.
We present a wideband balun-based microwave device for quantum manipulation of nitrogen-vacancy centers in diamond. The device employs a balun with multi-section Chebyshev impedance transformer to realize the conversion from the unbalanced feed line to the balanced feed line and ensures impedance matching. A bandwidth of 2.2 GHz with the maximum resonance frequency up to 4.4 GHz has been realized, which is important for multi-qubit quantum control of the nitrogen-vacancy centers. We also carry out optically detected magnetic resonance to observe Rabi oscillations and calibrate the strength of the microwave magnetic field generated by the microwave device. With an input power of 0.5 W, the Rabi frequencies can reach 6.17 MHz and 6.06 MHz for resonant microwave at 1.40 GHz and 4.34 GHz, respectively. Combining with large bandwidth and excellent magnetic field homogeneity, the device can be applied in solid-state quantum information processing.
Nitrogen-vacancy (NV) centers in diamond are solid-state quantum sensors that operate at room temperature and allow optical readout of spin states through optically detected magnetic resonance (ODMR). Reliable ODMR measurements need controlled microwave excitation to manipulate NV spin states and modulate their fluorescence. In this paper, we report on ensemble NV centers’ interaction with microwave fields transmitted by printed-circuit-board (PCB) radio-frequency (RF) devices. Two microwave structures, a coplanar waveguide transmission line (CPW-TL) and a single-finger interdigitated capacitor (IDC), are designed and impedance-matched at the NV zero-field splitting frequency. Nanodiamond solutions containing NV ensembles are deposited as few-microliter droplets onto the PCB devices and dried, forming localized NV layers on the RF structures. Two-dimensional fluorescence scans are used to link spatial changes in NV fluorescence to the microwave field distributions created by each device geometry. CPW-TLs enable interaction over extended regions along the transmission line, while IDCs produce localized excitation near the capacitive gaps.