Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Open Research Europe

Integrated coplanar waveguide coil on diamond for enhanced homogeneous broadband NV magnetometry

Hossein Babashah, Elena Losero, Christophe Galland

Published Mar 1, 2024• 6 citations
Publisher

Abstract

Nitrogen-vacancy (NV) centers in diamond have emerged as promising quantum sensors due to their highly coherent and optically addressable spin states with potential applications in high-sensitivity magnetometry. Homogeneously addressing large ensembles of NV centers offers clear benefit in terms of sensing precision as well as in fundamental studies of collective effects. Such experiments require a spatially uniform, intense, and broadband microwave field that can be difficult to generate. Previous approaches, such as copper wires, loop coils, and planar structures, have shown limitations in field homogeneity, bandwidth, and integration in compact devices. In this paper, we present a coplanar waveguide (CPW) gold coil patterned on a 3 × 3 mm 2 diamond substrate, offering full integration, enhanced stability, and broad bandwidth suitable for various NV sensing applications. Coil fabricated on diamond offers several advantages for magnetometry with NV centers ensemble, including enhanced heat dissipation, seamless integration, scalability, and miniaturization potential. We optimize critical geometrical parameters to achieve a homogeneous magnetic field with a coefficient of variation of less than 6% over an area of 0.5 mm 2 and present experimental results confirming the performance of the proposed CPW coil.

DOI
10.12688/openreseurope.16875.1

Related papers

Radio-Frequency Excitation for Quantum Sensing Based on Diamond NV Center Using Coplanar Waveguide Transmission Lines

Aashutosh Kumar, Maxime Colson, Richard Al Hadi +1 more

The Nitrogen-Vacancy (NV) center in diamond is a prominent quantum system leveraged for advanced quantum metrology, particularly in high-precision magnetometry and high-resolution quantum imaging, exploiting the Optically Detected Magnetic Resonance (ODMR) spectroscopy technique. Proper radio-frequency (RF) excitation of NV centers is critical in order to manipulate these quantum states effectively. Our research focuses on optimizing the continuous-wave RF excitation of ensembles of NV centers on coplanar waveguide transmission lines (CPW-TL), measuring the centers' photoluminescence (PL) signal as a function of RF power. This setup enhances the sensitivity and resolution of the NV center PL signal. By combining CPW-TL lines with nanodiamonds, our approach aims to develop a scalable and tunable platform that can be deployed in a variety of quantum sensing scenarios, including in biomedical applications, navigation systems, environmental monitorlng, and beyond.

IEEE International Conference on Quantum Computing and Engineering (QCE)•Sep 15, 2024•2 citations

Ultra-broadband coplanar waveguide for optically detected magnetic resonance of nitrogen-vacancy centers in diamond

Wenfei Jia, Zhifu Shi, Xi Qin +2 more

We report on coplanar waveguides (CPWs) designed for optically detected magnetic resonance of nitrogen-vacancy (NV) centers in diamonds. A broad band up to 15.8 GHz has been realized, which ensures that the electron spins can be manipulated under external magnetic fields up to 5000 G. The conversion factor of CPW has been measured by Rabi nutation experiments, which ranges from 6.64 G W−1/2 to 10.60 G W−1/2 in the frequency band from 0.76 GHz to 17.3 GHz. Broadband CPWs also provide high quality control pulses due to the minimization of the distortion. These characteristics will find potential applications in NV-based quantum information processing and single spin magnetometry.

Review of Scientific Instruments•Jun 1, 2018•26 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors

Yukitoshi Takemura, K. Hayashi, Y. Yoshii +9 more

Quantum sensors based on nitrogen-vacancy (NV) centers in diamond are expected to demonstrate a wide variety of applications. For high-sensitivity quantum sensors with NV center ensembles, uniform manipulation of the electron spins of the NV centers in large volumes is required. In addition, a broad microwave frequency bandwidth for manipulating the NV centers' electron spin is necessary for vector magnetometry and measurement under a finite static magnetic field. Here, we demonstrate a broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors. The simulation shows that the current is distributed at both edges of the loop coil of a single copper plate due to the skin effect. The loop coil acts like a Helmholtz coil, which realizes uniformity in the z-direction of the microwave magnetic field (B1). The plate structure has a higher mechanical stability, durability, and a larger heat capacity than the Helmholtz coil, due to its large volume. The antenna achieves a higher performance than previously reported antennae, with a maximal B1 of 4.5 G, a broad bandwidth of 287 ± 6 MHz, and a peak-to-peak variation of 9.2% over a 3.1 mm3 cylinder volume. These performances show that the presented antenna is suitable for manipulating solid-state spin ensembles for high-sensitivity quantum sensors.

Journal of Applied Physics•Dec 8, 2022•3 citations

Wideband microwave resonator for NV center vector magnetometry

S. V. Bolshedvorskii, E. A. Koreshin, V. V. Soshenko +10 more

The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about \[{1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;\]. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.

quant-pharXiv:2610.13379•Oct 12, 2026

Robust diamond-embedded microwave antenna for optimizing quantum sensing using nitrogen-vacancy center ensembles

Yuhang Guo, Jiaxin Zhao, Changfeng Weng +5 more

The nitrogen-vacancy (NV) color center in diamond has emerged as a promising candidate for quantum sensing. In this study, we propose a diamond-embedded metal antenna for magnetic detection utilizing NV center ensembles. Our approach involved employing nanofabrication and microwave plasma chemical vapor deposition techniques to fabricate the metal antenna and diamond epilayer. By directly embedding the antenna into the diamond, we effectively minimize external environmental interference, leading to improved device stability and reusability. Moreover, this integration enhances the device's compactness, making it highly suitable for on-chip quantum sensing applications. The innovative antenna design holds great potential for the development of future integrated quantum sensing devices based on NV centers in diamond.

Applied Physics Letters•Dec 25, 2023•10 citations
Nitrogen-vacancy (NV) centers in diamond have emerged as promising quantum sensors due to their highly coherent and optically addressable spin states with potential applications in high-sensitivity magnetometry. Homogeneously addressing large ensembles of NV centers offers clear benefit in terms of sensing precision as well as in fundamental studies of collective effects. Such experiments require a spatially uniform, intense, and broadband microwave field that can be difficult to generate. Previous approaches, such as copper wires, loop coils, and planar structures, have shown limitations in field homogeneity, bandwidth, and integration in compact devices. In this paper, we present a coplanar waveguide (CPW) gold coil patterned on a 3 × 3 mm 2 diamond substrate, offering full integration, enhanced stability, and broad bandwidth suitable for various NV sensing applications. Coil fabricated on diamond offers several advantages for magnetometry with NV centers ensemble, including enhanced heat dissipation, seamless integration, scalability, and miniaturization potential. We optimize critical geometrical parameters to achieve a homogeneous magnetic field with a coefficient of variation of less than 6% over an area of 0.5 mm 2 and present experimental results confirming the performance of the proposed CPW coil.
The Nitrogen-Vacancy (NV) center in diamond is a prominent quantum system leveraged for advanced quantum metrology, particularly in high-precision magnetometry and high-resolution quantum imaging, exploiting the Optically Detected Magnetic Resonance (ODMR) spectroscopy technique. Proper radio-frequency (RF) excitation of NV centers is critical in order to manipulate these quantum states effectively. Our research focuses on optimizing the continuous-wave RF excitation of ensembles of NV centers on coplanar waveguide transmission lines (CPW-TL), measuring the centers' photoluminescence (PL) signal as a function of RF power. This setup enhances the sensitivity and resolution of the NV center PL signal. By combining CPW-TL lines with nanodiamonds, our approach aims to develop a scalable and tunable platform that can be deployed in a variety of quantum sensing scenarios, including in biomedical applications, navigation systems, environmental monitorlng, and beyond.
We report on coplanar waveguides (CPWs) designed for optically detected magnetic resonance of nitrogen-vacancy (NV) centers in diamonds. A broad band up to 15.8 GHz has been realized, which ensures that the electron spins can be manipulated under external magnetic fields up to 5000 G. The conversion factor of CPW has been measured by Rabi nutation experiments, which ranges from 6.64 G W−1/2 to 10.60 G W−1/2 in the frequency band from 0.76 GHz to 17.3 GHz. Broadband CPWs also provide high quality control pulses due to the minimization of the distortion. These characteristics will find potential applications in NV-based quantum information processing and single spin magnetometry.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Quantum sensors based on nitrogen-vacancy (NV) centers in diamond are expected to demonstrate a wide variety of applications. For high-sensitivity quantum sensors with NV center ensembles, uniform manipulation of the electron spins of the NV centers in large volumes is required. In addition, a broad microwave frequency bandwidth for manipulating the NV centers' electron spin is necessary for vector magnetometry and measurement under a finite static magnetic field. Here, we demonstrate a broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors. The simulation shows that the current is distributed at both edges of the loop coil of a single copper plate due to the skin effect. The loop coil acts like a Helmholtz coil, which realizes uniformity in the z-direction of the microwave magnetic field (B1). The plate structure has a higher mechanical stability, durability, and a larger heat capacity than the Helmholtz coil, due to its large volume. The antenna achieves a higher performance than previously reported antennae, with a maximal B1 of 4.5 G, a broad bandwidth of 287 ± 6 MHz, and a peak-to-peak variation of 9.2% over a 3.1 mm3 cylinder volume. These performances show that the presented antenna is suitable for manipulating solid-state spin ensembles for high-sensitivity quantum sensors.
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about 1.2 nT/Hz  {1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;1.2 nT/Hz​. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.
The nitrogen-vacancy (NV) color center in diamond has emerged as a promising candidate for quantum sensing. In this study, we propose a diamond-embedded metal antenna for magnetic detection utilizing NV center ensembles. Our approach involved employing nanofabrication and microwave plasma chemical vapor deposition techniques to fabricate the metal antenna and diamond epilayer. By directly embedding the antenna into the diamond, we effectively minimize external environmental interference, leading to improved device stability and reusability. Moreover, this integration enhances the device's compactness, making it highly suitable for on-chip quantum sensing applications. The innovative antenna design holds great potential for the development of future integrated quantum sensing devices based on NV centers in diamond.