Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Research on metrology method of surface magnetic field based on the nitrogen-vacancy center (NV) in diamonds

Jinglu Sun, Peiyan Zhang, Rui Ji, Xiangyang Zhang

Published Sep 1, 2024• 0 citations
Publisher

Abstract

This paper proposes a novel metrology method for surface magnetic fields based on the nitrogen-vacancy (NV) center in a diamond. A coplanar waveguide is used to calibrate the NV center, and its standard values are derived from its simulation results. This metrology method involves leveraging quantum NV scanning technology to capture the Optically Detected Magnetic Resonance (ODMR) spectrum and Rabi oscillation curves of the waveguide, and test data of the surface magnetic field of the coplanar waveguide are meticulously extrapolated through a rigorous fitting process. We compare the test data and simulation results to verify the accuracy of the metrology method. This method promises to enhance the fidelity of magnetic field distribution measurements on chip surfaces, thereby elevating the standards of chip testing accuracy for future applications.

DOI
10.1088/1742-6596/2849/1/012040

Related papers

Radio-Frequency Excitation for Quantum Sensing Based on Diamond NV Center Using Coplanar Waveguide Transmission Lines

Aashutosh Kumar, Maxime Colson, Richard Al Hadi +1 more

The Nitrogen-Vacancy (NV) center in diamond is a prominent quantum system leveraged for advanced quantum metrology, particularly in high-precision magnetometry and high-resolution quantum imaging, exploiting the Optically Detected Magnetic Resonance (ODMR) spectroscopy technique. Proper radio-frequency (RF) excitation of NV centers is critical in order to manipulate these quantum states effectively. Our research focuses on optimizing the continuous-wave RF excitation of ensembles of NV centers on coplanar waveguide transmission lines (CPW-TL), measuring the centers' photoluminescence (PL) signal as a function of RF power. This setup enhances the sensitivity and resolution of the NV center PL signal. By combining CPW-TL lines with nanodiamonds, our approach aims to develop a scalable and tunable platform that can be deployed in a variety of quantum sensing scenarios, including in biomedical applications, navigation systems, environmental monitorlng, and beyond.

IEEE International Conference on Quantum Computing and Engineering (QCE)•Sep 15, 2024•2 citations

Nitrogen Vacancy Centers in Diamond for Quantum Biosensing: Magnetometry Techniques, Platforms and Applications

Sirsendu Ghosal, Umakant Prajapati, Sachin Negi +3 more

Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.

quant-pharXiv:2609.04733•Sep 7, 2026

Ultra-broadband coplanar waveguide for optically detected magnetic resonance of nitrogen-vacancy centers in diamond

Wenfei Jia, Zhifu Shi, Xi Qin +2 more

We report on coplanar waveguides (CPWs) designed for optically detected magnetic resonance of nitrogen-vacancy (NV) centers in diamonds. A broad band up to 15.8 GHz has been realized, which ensures that the electron spins can be manipulated under external magnetic fields up to 5000 G. The conversion factor of CPW has been measured by Rabi nutation experiments, which ranges from 6.64 G W−1/2 to 10.60 G W−1/2 in the frequency band from 0.76 GHz to 17.3 GHz. Broadband CPWs also provide high quality control pulses due to the minimization of the distortion. These characteristics will find potential applications in NV-based quantum information processing and single spin magnetometry.

Review of Scientific Instruments•Jun 1, 2018•27 citations

Vector Magnetometry with Broadband Microwave Fields in Nitrogen-Vacancy Centers in Diamond

Tom R. Rieckmann, Arezoo Afshar, Aaron Z. Goldberg +3 more

We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers. In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses and measures them after transmission through the NV sensor medium, thus capturing the line splitting of the ground state triplet due to the Zeeman effect. Two orthogonally polarized microwave pulses allow resolving all magnetic field components independently by reading out differently oriented NV centers. Simulated data is analyzed using deep neural networks, whose efficacy we expect to translate very well to experiments. Our method yields sensitivities between $5~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ and $100~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ across different magnetic field vector components, while achieving approximately $\mathrm{nT}$ accuracy at a signal-to-noise (SNR) ratio of $70~\mathrm{dB}$. By being capable of accurately measuring magnetic fields down to $25~\mathrm{μT}$, the need for a bias field beyond Earth's magnetic field is eliminated.

quant-pharXiv:2606.02749•Jun 3, 2026

Nitrogen vacancies (NV) centers in diamond for magnetic sensors and quantum sensing

Mayeul Chipaux, Stéphane Xavier, Alexandre Tallaire +6 more

Nitrogen Vacancy (NV) centers are point defects in diamond that allow magnetic field sensing based on Optically Detected Magnetic Resonance (ODMR). They are processed in ultrapure single-domain CVD grown diamond crystals and can be operated at room temperature. This results in solid-state sensors with a wide variety of applications. Ensemble of NV centers can be used to perform wide-field magnetic imaging with sensitivity in the nT range. Single NV centers can also be processed, which allows sensing at the atomic scale. This possibility, combined with its unique coherence properties, make NV center an ideal candidate for quantum sensing.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 8, 2015•4 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Aug 18, 2021•1 citation
This paper proposes a novel metrology method for surface magnetic fields based on the nitrogen-vacancy (NV) center in a diamond. A coplanar waveguide is used to calibrate the NV center, and its standard values are derived from its simulation results. This metrology method involves leveraging quantum NV scanning technology to capture the Optically Detected Magnetic Resonance (ODMR) spectrum and Rabi oscillation curves of the waveguide, and test data of the surface magnetic field of the coplanar waveguide are meticulously extrapolated through a rigorous fitting process. We compare the test data and simulation results to verify the accuracy of the metrology method. This method promises to enhance the fidelity of magnetic field distribution measurements on chip surfaces, thereby elevating the standards of chip testing accuracy for future applications.
The Nitrogen-Vacancy (NV) center in diamond is a prominent quantum system leveraged for advanced quantum metrology, particularly in high-precision magnetometry and high-resolution quantum imaging, exploiting the Optically Detected Magnetic Resonance (ODMR) spectroscopy technique. Proper radio-frequency (RF) excitation of NV centers is critical in order to manipulate these quantum states effectively. Our research focuses on optimizing the continuous-wave RF excitation of ensembles of NV centers on coplanar waveguide transmission lines (CPW-TL), measuring the centers' photoluminescence (PL) signal as a function of RF power. This setup enhances the sensitivity and resolution of the NV center PL signal. By combining CPW-TL lines with nanodiamonds, our approach aims to develop a scalable and tunable platform that can be deployed in a variety of quantum sensing scenarios, including in biomedical applications, navigation systems, environmental monitorlng, and beyond.
Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.
We report on coplanar waveguides (CPWs) designed for optically detected magnetic resonance of nitrogen-vacancy (NV) centers in diamonds. A broad band up to 15.8 GHz has been realized, which ensures that the electron spins can be manipulated under external magnetic fields up to 5000 G. The conversion factor of CPW has been measured by Rabi nutation experiments, which ranges from 6.64 G W−1/2 to 10.60 G W−1/2 in the frequency band from 0.76 GHz to 17.3 GHz. Broadband CPWs also provide high quality control pulses due to the minimization of the distortion. These characteristics will find potential applications in NV-based quantum information processing and single spin magnetometry.
We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers. In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses and measures them after transmission through the NV sensor medium, thus capturing the line splitting of the ground state triplet due to the Zeeman effect. Two orthogonally polarized microwave pulses allow resolving all magnetic field components independently by reading out differently oriented NV centers. Simulated data is analyzed using deep neural networks, whose efficacy we expect to translate very well to experiments. Our method yields sensitivities between 5 pT/Hz5~\mathrm{pT}/\sqrt{\mathrm{Hz}}5 pT/Hz​ and 100 pT/Hz100~\mathrm{pT}/\sqrt{\mathrm{Hz}}100 pT/Hz​ across different magnetic field vector components, while achieving approximately nT\mathrm{nT}nT accuracy at a signal-to-noise (SNR) ratio of 70 dB70~\mathrm{dB}70 dB. By being capable of accurately measuring magnetic fields down to 25 μT25~\mathrm{μT}25 μT, the need for a bias field beyond Earth's magnetic field is eliminated.
Nitrogen Vacancy (NV) centers are point defects in diamond that allow magnetic field sensing based on Optically Detected Magnetic Resonance (ODMR). They are processed in ultrapure single-domain CVD grown diamond crystals and can be operated at room temperature. This results in solid-state sensors with a wide variety of applications. Ensemble of NV centers can be used to perform wide-field magnetic imaging with sensitivity in the nT range. Single NV centers can also be processed, which allows sensing at the atomic scale. This possibility, combined with its unique coherence properties, make NV center an ideal candidate for quantum sensing.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.