Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

A millimeter magnetic trap for a dual (85Rb and 87Rb) species atom interferometer

J Alibert, Boris Décamps, Maxime Bordoux, Baptiste Allard, A. Gauguet

Published Nov 1, 2017• 3 citations
Publisher

Abstract

We present a magnetic trap for cold atoms near a surface of a millimeter-sized atom chip. The trap allows us to capture a large number of atoms with modest electrical currents (40 A) and to generate large magnetic gradients (>300 G cm−1). Here we report a mixture containing 6 × 109 atoms for the two rubidium isotopes 87Rb and 85Rb. This device does not require cleanroom facilities nor micro-machining technologies which makes its construction easier. In addition our design allows the implementation of an optical dipole trap with a laser beam passing through the chip.

DOI
10.1063/1.4997149

Related papers

Design of a millimetre-scale magnetic surface trap for cold atoms

D Trypogeorgos, Stephen D. Albright, D Beesley +1 more

We study a novel millimetre-scale magnetic trap for ultracold atoms, in which the current carrying conductors can be situated outside the vacuum region, a few mm away from the atoms. This design generates a magnetic field gradient in excess of \SI{1000}{G/cm} at a distance of \SI{2}{mm} from the conductors. We perform electromagnetic and thermo-mechanical characterisation using Finite Element Methods (FEM). The predicted behaviour has been verified by electrical and thermal measurements on a prototype, but has not been implemented on an apparatus with cold atoms. Operating this trap at the highest gradient allows for rapid evaporative cooling comparable to that achieved by atom chips.

arXiv:1311.0250•Journal of Physics B Atomic Molecular and Optical Physics•Mar 17, 2014•3 citations

Dual atom (87Rb-133Cs) grating magneto-optical trap

Lei Xu, Muming Li, Zhilong Yu +5 more

This paper proposes a dual-color grating chip design method for simultaneously capturing dual atomic clouds (87Rb and 133Cs). By simulating key parameters such as the grating period, etching depth, duty cycle, coating material, and thickness, the optimal design parameters were determined to ensure efficient dual-wavelength diffraction and maximize the number of captured atoms. Experimental results demonstrate the simultaneous trapping of 1.6E8 87Rb atoms and 7.8E6 133Cs atoms, thereby offering an approach for multi-species cold atom systems. This dual-species grating magneto-optical trap (GMOT) system has potential applications in precision measurements such as cold atom clocks, quantum interferometers, and quantum electrometry.

arXiv:2412.14440•Dec 19, 2024•0 citations

A cold atom apparatus for the microscopy of thin membranes

Amruta Gadge

Ultracold atomic gases can be utilised as extremely sensitive probes of their surrounding environment. In particular, samples of ultracold atoms confined using chip-based microtraps are an ideal tool for mapping electric and magnetic field landscapes. Over the course of this thesis, a new experiment capable of performing surface microscopy using magnetically trapped clouds of cold rubidium-87 atoms has been built. The focus of the work is on the design and construction of the experimental system, which must incorporate many different aspects for manipulating thermal atomic gases, with a view to positioning them at sub-micron distances from special surfaces. This reduced atom-surface separation is necessary for implementing a high resolution, high sensitivity magnetic field sensor with cold atoms. Although current microfabrication techniques easily enable trapping at distances on the order of micrometres, several distance-dependent surface effects - such as the Casimir-Polder force, Johnson-Nyquist noise, and stray potentials - eventually impede magnetic trapping at the sub-micron level. These surface effects can greatly modify the confining potentials, which reduces the trap depth and consequently leads to an additional loss rate of atoms from the trap. We have explored the possibility of using special surfaces such as nano-membranes of silicon nitride and graphene, which have reduced atom- surface interactions, to enable trapping distances at the sub-micron level. A multilayer printed circuit board chip has been designed to form an initial magnetic trap and then transport the cloud of atoms to a desired location over the samples. This chip, along with various samples, is mounted on a custom-made electrical feedthrough designed to make connections to all conductor that are inside the vacuum chamber. The initial cloud of cold atoms can then be prepared in the central region of the chip and delivered to the location of the samples on either side. The experimental system is able to routinely capture over 10^8 rubidium-87 atoms at a temperature of 80 micro-Kelvin in a magneto-optical trap using a novel scheme of five laser beams. A method is demonstrated for enhancing the atom number in the magneto-optical traps by a factor of two by using laser beams with two slightly different frequencies. Atoms from the magneto-optical trap are then transferred to a purely magnetic trap formed by the wires on the printed circuit board chip. Time-dependent currents in the chip wires then create a dynamic potential, which is shown to successfully transport the atomic sample over a distance of 12 millimetre with minimal atom loss. This thesis describes the development of the apparatus in detail, along with careful characterisation of the cold cloud at various stages of the experimental sequence. Initial results on the long distance atom transport are presented. Finally, the experimental results of the two frequency magneto-optical trap for atom number improvement are discussed.

•Jul 19, 2018•0 citations

An atom chip for the manipulation of ultracold atoms

Owen Cherry, J. D. Carter, J. D. D. Martin

We have fabricated an atom chip that magnetically traps laser cooled 87Rb by generating high magnetic-field gradients using micrometre scale current-carrying wires. The wires are fabricated on a Si wafer (with a 40 nm SiO2 layer) using 1.2 μm thick Au and a 20 nm thick adhesion layer, and are patterned with lift-off photolithography. We characterize the number and temperature of the cold atoms trapped by the chip.

Canadian Journal of Physics•Jun 1, 2009•6 citations

Optimization of magneto-optical trap parameters for dual-atom gravimeters using 87Rb and 85Rb

Rui Xu, Fangjun Qin, Zhichao Ding +4 more

Abstract This study establishes a magneto-optical trap system for trapping cold atoms. By employing image processing techniques, we identified the actual size of the trapped cold atom cluster and assessed the variations in the number of trapped cold atoms. We have successfully trapped for both 87Rb and 85Rb atoms. Optimal parameters were determined for cooling laser power, cooling laser detuning, repumping laser power, and magnetic field current to maximize the number of trapped cold atoms. The optimization results and methods presented in this paper can be applied to validate the equivalence principle and in dual-test quantum gravimeters.

Physica Scripta•May 22, 2025•0 citations

Bose-Einstein condensation in micro-potentials for atom interferometry

F. Scharnberg

Interferometry with atoms is a young discipline of physics. The ¯rst interfer- ometers were realised in the early 1990s, using light pulses as beamsplitters in momentum space. Recent developments in atom optics have led to new proposals for interferometers, where the splitting takes place spatially. Mag- netic and optical traps are both suited for this kind of interferometer if a well de¯ned and highly controllable trap is realised. In this thesis results from two experiments that in principle allow the creation of such traps are presented. After reviewing the principles and techniques of atom optics necessary for the understanding of this thesis, a theoretical discussion about the spatial single atom interferometer in a double well potential follows. It is shown that within reasonable limits the system can be reduced to two levels and solved by the Bloch equations. Using the realistic case of a not perfectly symmetric double well potential allows an understanding of the physics behind such an interferometer: how phase is accumulated and how localisation of the atoms leads to the loss of the interferometric signal. Then two experiments are presented. One experiment was newly built up as part of this thesis: it uses a novel hybrid atom chip' with a combination of a magneto-optical ¯lm and current-carrying structures to produce the magnetic trapping potentials. This experiment allowed 5¢108 87Rb atoms to be captured in a magneto-optical trap, where the atom-chip's surface acts as a mirror. The atoms were then transferred into a purely magnetic trap which was created by current carrying structures on the chip. From there on, RF radiation enforced evaporative cooling, so that a quantum degenerate Bose-Einstein condensate of up to 105 atoms was created. It was also shown that the magneto-optical ¯lm is able to hold and trap the atoms. In the second experiment atoms are trapped in the spatially varying inten- sity of light of 1.03 ¹m wavelength. This experiment used an existing set-up as a basis and was modi¯ed and improved for this new project. This experiment starts with 109 87Rb atoms in a 6-beam magneto-optical trap. After examining and optimising the loading process, 1:5 ¢ 105 atoms could be loaded directly from the Magneto-optical trap into the optical dipole potential of two crossed laser beams at 1.03 ¹m. Evaporative cooling was demonstrated though the phase transition to quantum degeneracy was not reached.

•Jan 1, 2024•1 citation
We present a magnetic trap for cold atoms near a surface of a millimeter-sized atom chip. The trap allows us to capture a large number of atoms with modest electrical currents (40 A) and to generate large magnetic gradients (>300 G cm−1). Here we report a mixture containing 6 × 109 atoms for the two rubidium isotopes 87Rb and 85Rb. This device does not require cleanroom facilities nor micro-machining technologies which makes its construction easier. In addition our design allows the implementation of an optical dipole trap with a laser beam passing through the chip.
We study a novel millimetre-scale magnetic trap for ultracold atoms, in which the current carrying conductors can be situated outside the vacuum region, a few mm away from the atoms. This design generates a magnetic field gradient in excess of \SI{1000}{G/cm} at a distance of \SI{2}{mm} from the conductors. We perform electromagnetic and thermo-mechanical characterisation using Finite Element Methods (FEM). The predicted behaviour has been verified by electrical and thermal measurements on a prototype, but has not been implemented on an apparatus with cold atoms. Operating this trap at the highest gradient allows for rapid evaporative cooling comparable to that achieved by atom chips.
This paper proposes a dual-color grating chip design method for simultaneously capturing dual atomic clouds (87Rb and 133Cs). By simulating key parameters such as the grating period, etching depth, duty cycle, coating material, and thickness, the optimal design parameters were determined to ensure efficient dual-wavelength diffraction and maximize the number of captured atoms. Experimental results demonstrate the simultaneous trapping of 1.6E8 87Rb atoms and 7.8E6 133Cs atoms, thereby offering an approach for multi-species cold atom systems. This dual-species grating magneto-optical trap (GMOT) system has potential applications in precision measurements such as cold atom clocks, quantum interferometers, and quantum electrometry.
Ultracold atomic gases can be utilised as extremely sensitive probes of their surrounding environment. In particular, samples of ultracold atoms confined using chip-based microtraps are an ideal tool for mapping electric and magnetic field landscapes. Over the course of this thesis, a new experiment capable of performing surface microscopy using magnetically trapped clouds of cold rubidium-87 atoms has been built. The focus of the work is on the design and construction of the experimental system, which must incorporate many different aspects for manipulating thermal atomic gases, with a view to positioning them at sub-micron distances from special surfaces. This reduced atom-surface separation is necessary for implementing a high resolution, high sensitivity magnetic field sensor with cold atoms. Although current microfabrication techniques easily enable trapping at distances on the order of micrometres, several distance-dependent surface effects - such as the Casimir-Polder force, Johnson-Nyquist noise, and stray potentials - eventually impede magnetic trapping at the sub-micron level. These surface effects can greatly modify the confining potentials, which reduces the trap depth and consequently leads to an additional loss rate of atoms from the trap. We have explored the possibility of using special surfaces such as nano-membranes of silicon nitride and graphene, which have reduced atom- surface interactions, to enable trapping distances at the sub-micron level. A multilayer printed circuit board chip has been designed to form an initial magnetic trap and then transport the cloud of atoms to a desired location over the samples. This chip, along with various samples, is mounted on a custom-made electrical feedthrough designed to make connections to all conductor that are inside the vacuum chamber. The initial cloud of cold atoms can then be prepared in the central region of the chip and delivered to the location of the samples on either side. The experimental system is able to routinely capture over 10^8 rubidium-87 atoms at a temperature of 80 micro-Kelvin in a magneto-optical trap using a novel scheme of five laser beams. A method is demonstrated for enhancing the atom number in the magneto-optical traps by a factor of two by using laser beams with two slightly different frequencies. Atoms from the magneto-optical trap are then transferred to a purely magnetic trap formed by the wires on the printed circuit board chip. Time-dependent currents in the chip wires then create a dynamic potential, which is shown to successfully transport the atomic sample over a distance of 12 millimetre with minimal atom loss. This thesis describes the development of the apparatus in detail, along with careful characterisation of the cold cloud at various stages of the experimental sequence. Initial results on the long distance atom transport are presented. Finally, the experimental results of the two frequency magneto-optical trap for atom number improvement are discussed.
Abstract This study establishes a magneto-optical trap system for trapping cold atoms. By employing image processing techniques, we identified the actual size of the trapped cold atom cluster and assessed the variations in the number of trapped cold atoms. We have successfully trapped for both 87Rb and 85Rb atoms. Optimal parameters were determined for cooling laser power, cooling laser detuning, repumping laser power, and magnetic field current to maximize the number of trapped cold atoms. The optimization results and methods presented in this paper can be applied to validate the equivalence principle and in dual-test quantum gravimeters.
Interferometry with atoms is a young discipline of physics. The ¯rst interfer- ometers were realised in the early 1990s, using light pulses as beamsplitters in momentum space. Recent developments in atom optics have led to new proposals for interferometers, where the splitting takes place spatially. Mag- netic and optical traps are both suited for this kind of interferometer if a well de¯ned and highly controllable trap is realised. In this thesis results from two experiments that in principle allow the creation of such traps are presented. After reviewing the principles and techniques of atom optics necessary for the understanding of this thesis, a theoretical discussion about the spatial single atom interferometer in a double well potential follows. It is shown that within reasonable limits the system can be reduced to two levels and solved by the Bloch equations. Using the realistic case of a not perfectly symmetric double well potential allows an understanding of the physics behind such an interferometer: how phase is accumulated and how localisation of the atoms leads to the loss of the interferometric signal. Then two experiments are presented. One experiment was newly built up as part of this thesis: it uses a novel hybrid atom chip' with a combination of a magneto-optical ¯lm and current-carrying structures to produce the magnetic trapping potentials. This experiment allowed 5¢108 87Rb atoms to be captured in a magneto-optical trap, where the atom-chip's surface acts as a mirror. The atoms were then transferred into a purely magnetic trap which was created by current carrying structures on the chip. From there on, RF radiation enforced evaporative cooling, so that a quantum degenerate Bose-Einstein condensate of up to 105 atoms was created. It was also shown that the magneto-optical ¯lm is able to hold and trap the atoms. In the second experiment atoms are trapped in the spatially varying inten- sity of light of 1.03 ¹m wavelength. This experiment used an existing set-up as a basis and was modi¯ed and improved for this new project. This experiment starts with 109 87Rb atoms in a 6-beam magneto-optical trap. After examining and optimising the loading process, 1:5 ¢ 105 atoms could be loaded directly from the Magneto-optical trap into the optical dipole potential of two crossed laser beams at 1.03 ¹m. Evaporative cooling was demonstrated though the phase transition to quantum degeneracy was not reached.