Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Optical sampling analog-to-digital scheme for broadband microwave signal based on atomic resonator

Hongling Meng, Ruiyuan Liu, Jianye Zhao

Published Jul 1, 2017• 0 citations
Publisher

Abstract

We report a long-term stabilization optical sampling analog-to-digital scheme for broadband microwave signal based on a rubidium coherent population trapping (CPT) atomic resonator. With this scheme, we can realize analog-to-digital conversion with broadband microwave signal based on optical combs with low repetition rate and the optical sampling ADC system also becomes a long-term stabilization system. The frequency stability performance of 8×10-11τ1/2from 1 s to 103s is obtained and the frequency drift is 1.6×10-12for one day. With this scheme, we could achieve 7 bit ENOB at about tens of GHz carrier frequency over 50MHz bandwidth.

DOI
10.1109/fcs.2017.8089024

Related papers

CPT atomic clock based on rubidium 85

C. Schori, G. Mileti, B. Leuenbeger +1 more

We present a compact physics package based on coherent population trapping (CPT) in rubidium 85. The architecture of the package is described along with results obtained using optical- and microwave spectroscopy. We also report the stability of the CPT resonance to variations in operating parameters such as microwave modulation power and vapour cell temperature. With this package we obtain a short term frequency stability σy(τ) = 7·10-11·τ-1/2(τy(τ) ~ 1·10-11( 100 sec4sec).

European Frequency and Time Forum•Apr 1, 2010•12 citations

High-performance coherent population trapping clock based on laser-cooled atoms

Xiaochi Liu, Ning Ru, Junyi Duan +3 more

We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.

Chinese Physics B•Oct 6, 2021•8 citations

Microwave phase detection of coherent population trapping resonance in a Cs vapor cell

Michael Petersen, Moustafa Abdel Hafiz, Emeric de Clercq +1 more

We report a phase-sensitive microwave detection setup for spectroscopy of coherent population trapping (CPT) resonance in a Cs vapor cell. In this scheme, the optically carried microwave interrogation signal that interacts with atoms is detected by a fast photodiode at the cell output and is then mixed with the local oscillator microwave signal itself. This detection scheme produces at the output of the microwave mixer a dispersive CPT signal that can be directly used for correction of the local oscillator frequency onto the atomic resonance. The evolution of the dispersive CPT resonance signal with the laser power is briefly reported. With this detection scheme, we demonstrate the operation of a CPT atomic clock with a short-term fractional frequency stability of 1 × 10 − 11 at 1 s, which is in good agreement with the slope of the frequency discriminator and the residual microwave phase noise of the setup.

Journal of the Optical Society of America B•Feb 3, 2022•3 citations

All-optical atomic clock based on coherent population trapping in ^85Rb

Mikko Merimaa, Thomas Lindvall, Ilkka Juhani Tittonen +1 more

An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.

Journal of the Optical Society of America B•Feb 1, 2003•132 citations

Stabilization method for atomic clocks to detect the maximum coherent-population-trapping resonance signal

Yusuke Odagiri, Satoshi Hatano, Yuichiro Yano +3 more

Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.

Japanese Journal of Applied Physics•Jun 1, 2025•2 citations

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations
We report a long-term stabilization optical sampling analog-to-digital scheme for broadband microwave signal based on a rubidium coherent population trapping (CPT) atomic resonator. With this scheme, we can realize analog-to-digital conversion with broadband microwave signal based on optical combs with low repetition rate and the optical sampling ADC system also becomes a long-term stabilization system. The frequency stability performance of 8×10-11τ1/2from 1 s to 103s is obtained and the frequency drift is 1.6×10-12for one day. With this scheme, we could achieve 7 bit ENOB at about tens of GHz carrier frequency over 50MHz bandwidth.
We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.
We report a phase-sensitive microwave detection setup for spectroscopy of coherent population trapping (CPT) resonance in a Cs vapor cell. In this scheme, the optically carried microwave interrogation signal that interacts with atoms is detected by a fast photodiode at the cell output and is then mixed with the local oscillator microwave signal itself. This detection scheme produces at the output of the microwave mixer a dispersive CPT signal that can be directly used for correction of the local oscillator frequency onto the atomic resonance. The evolution of the dispersive CPT resonance signal with the laser power is briefly reported. With this detection scheme, we demonstrate the operation of a CPT atomic clock with a short-term fractional frequency stability of 1 × 10 − 11 at 1 s, which is in good agreement with the slope of the frequency discriminator and the residual microwave phase noise of the setup.
An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.
Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.