Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

High-performance coherent population trapping clock based on laser-cooled atoms

Xiaochi Liu, Ning Ru, Junyi Duan, Peter Yun, Minghao Yao, Jifeng Qu

Published Oct 6, 2021• 8 citations
Publisher

Abstract

We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.

DOI
10.1088/1674-1056/ac2d21

Related papers

Development of a Compact Cold-Atom Atomic Clock Based on Coherent Population Trapping

E. Blanshan

Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in a variety of applications ranging from network synchronization and secure communications to GPS hold-over and inertial navigation. A cold-atom coherent population trapping (CACPT) clock featuring laser-cooled 87RB atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the principal frequency shifts can be controlled and the performance degradation associated with miniaturization can be overcome. In this thesis, research focused on the development of this type of compact atomic clock is presented. To address the low atom numbers obtained in small cold-atom sources, experiments were performed in which an atomic beam was decelerated with bichromatic stimulated laser forces and loaded into a mm-scale magneto-optical trap, increasing the atom number by a factor of 12.5x. A CACPT clock using the high-contrast lin||lin optical interrogation technique was developed and achieved a stability of 7 × 10-13 after one hour of integration. Doppler shifts in the clock are explained using a simple kinematic model and canceled by interrogating the atoms with a counter-propagating CPT configuration. Finally, a thorough characterization of the AC-stark effect in lin||lin CPT was performed. Observed shifts are explained in terms of contributions from coherent CPT-generating couplings and population transfer effects caused by optical pumping from incoherent light. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that reduces clock drift from light shifts to less than 10-14 for the current system.

•Jan 1, 2014•2 citations

Towards a compact atomic clock based on coherent population trapping and the grating magneto-optical trap

Erling Riis, Gregory W. Hoth, Rachel Elvin +4 more

The combination of coherent population trapping (CPT) and laser cooled atoms is a promising platform for realizing the next generation of compact atomic frequency references. Towards this goal, we have developed an apparatus based on the grating magneto-optical trap (GMOT) and the high-contrast lin ⊥ lin CPT scheme in order to explore the performance that can be achieved. One important trade-off for cold-atom systems arises from the need to simultaneously maximize the number of cold atoms available for interrogation and the repetition rate of the system. This compromise can be mitigated by recapturing cold atoms from cycle to cycle. Here, we report a quantitative characterization of the cold atom number in the recapture regime for our system, which will enable us to optimize this trade-off. We also report recent measurements of the short-term frequency stability with a short-term Allan deviation of 3 × 10-11/τ up to an averaging time of τ = 10 s.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•4 citations

Frequency biases in a cold-atom coherent population trapping clock

Elizabeth A. Donley, E. Blanshan, François-Xavier Esnault +1 more

A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•2 citations

Cold-atom double- Λ coherent population trapping clock

François-Xavier Esnault, E. Blanshan, Eugene N. Ivanov +3 more

Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on ${}^{87}$Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.

Physical Review A•Oct 31, 2013•83 citations

A cold-atom beam clock based on coherent population trapping

John Elgin, Thomas P. Heavner, John E. Kitching +3 more

We present results from an atomic clock that employs a beam of cold 87Rb atoms and spatially separated (Ramsey) coherent population trapping interrogation of the hyperfine clock transition at 6.834 GHz. The cold atomic beam is generated through the use of a 2D+-magneto-optical trap. The interrogation is performed on the D2 line of 87Rb, and the optical fields use a counter-propagating σ+–σ− probing scheme. The use of cold atoms allows for relatively narrow Ramsey fringes even for a small spatial separation between the two interrogation zones (4.6 cm). The resulting clock has a short-term stability of 3×10−11/τ.

Applied Physics Letters•Jul 15, 2019•31 citations

Feasibility toward a compact high performance coherent population trapping clock

Peter Yun, François Tricot, Emeric de Clercq +4 more

We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.

•Apr 14, 2019•0 citations
We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.
Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in a variety of applications ranging from network synchronization and secure communications to GPS hold-over and inertial navigation. A cold-atom coherent population trapping (CACPT) clock featuring laser-cooled 87RB atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the principal frequency shifts can be controlled and the performance degradation associated with miniaturization can be overcome. In this thesis, research focused on the development of this type of compact atomic clock is presented. To address the low atom numbers obtained in small cold-atom sources, experiments were performed in which an atomic beam was decelerated with bichromatic stimulated laser forces and loaded into a mm-scale magneto-optical trap, increasing the atom number by a factor of 12.5x. A CACPT clock using the high-contrast lin||lin optical interrogation technique was developed and achieved a stability of 7 × 10-13 after one hour of integration. Doppler shifts in the clock are explained using a simple kinematic model and canceled by interrogating the atoms with a counter-propagating CPT configuration. Finally, a thorough characterization of the AC-stark effect in lin||lin CPT was performed. Observed shifts are explained in terms of contributions from coherent CPT-generating couplings and population transfer effects caused by optical pumping from incoherent light. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that reduces clock drift from light shifts to less than 10-14 for the current system.
The combination of coherent population trapping (CPT) and laser cooled atoms is a promising platform for realizing the next generation of compact atomic frequency references. Towards this goal, we have developed an apparatus based on the grating magneto-optical trap (GMOT) and the high-contrast lin ⊥ lin CPT scheme in order to explore the performance that can be achieved. One important trade-off for cold-atom systems arises from the need to simultaneously maximize the number of cold atoms available for interrogation and the repetition rate of the system. This compromise can be mitigated by recapturing cold atoms from cycle to cycle. Here, we report a quantitative characterization of the cold atom number in the recapture regime for our system, which will enable us to optimize this trade-off. We also report recent measurements of the short-term frequency stability with a short-term Allan deviation of 3 × 10-11/τ up to an averaging time of τ = 10 s.
A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.
Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on 87{}^{87}87Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.
We present results from an atomic clock that employs a beam of cold 87Rb atoms and spatially separated (Ramsey) coherent population trapping interrogation of the hyperfine clock transition at 6.834 GHz. The cold atomic beam is generated through the use of a 2D+-magneto-optical trap. The interrogation is performed on the D2 line of 87Rb, and the optical fields use a counter-propagating σ+–σ− probing scheme. The use of cold atoms allows for relatively narrow Ramsey fringes even for a small spatial separation between the two interrogation zones (4.6 cm). The resulting clock has a short-term stability of 3×10−11/τ.
We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.