CPT atomic clock based on rubidium 85

C. Schori, G. Mileti, B. Leuenbeger, Pascal Rochat

Published Apr 1, 2010• 13 citations
Publisher

Abstract

We present a compact physics package based on coherent population trapping (CPT) in rubidium 85. The architecture of the package is described along with results obtained using optical- and microwave spectroscopy. We also report the stability of the CPT resonance to variations in operating parameters such as microwave modulation power and vapour cell temperature. With this package we obtain a short term frequency stability σy(τ) = 7·10-11·τ-1/2(τy(τ) ~ 1·10-11( 100 sec4sec).

DOI
10.1109/eftf.2010.6533686

Related papers

Properties of Rb CPT Atomic Clock at Subharmonic Microwave Modulation Frequencies

Daba A. Radnatarov, Sergey M Kobtsev, Valeriy Andryushkov +3 more

This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.

IEEE photonics journal•Jun 26, 2019•2 citations

A chip-scale atomic clock based on ^87Rb with improved frequency stability

Svenja A. Knappe, Peter D. D. Schwindt, Vishal Shah +4 more

We demonstrate a microfabricated atomic clock physics package based on coherent population trapping (CPT) on the D1 line of 87Rb atoms. The package occupies a volume of 12 mm3 and requires 195 mW of power to operate at an ambient temperature of 200 degrees C. Compared to a previous microfabricated clock exciting the D2 transition in Cs [1], this 87Rb clock shows significantly improved short- and long-term stability. The instability at short times is 4 x?10-11 / tau?/2 and the improvement over the Cs device is due mainly to an increase in resonance amplitude. At longer times (tau?> 50 s), the improvement results from the reduction of a slow drift to ?5 x 10-9 / day. The drift is most likely caused by a chemical reaction of nitrogen and barium inside the cell. When probing the atoms on the D1 line, spin-exchange collisions between Rb atoms and optical pumping appear to have increased importance compared to the D2 line.

Optics Express•Jan 1, 2005•238 citations

All-optical atomic clock based on coherent population trapping in ^85Rb

Mikko Merimaa, Thomas Lindvall, Ilkka Juhani Tittonen +1 more

An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.

Journal of the Optical Society of America B•Feb 1, 2003•131 citations

Frequency Shifts in a Coherent Population Trapping Cs Vapor Cell Atomic Clock

Juliette Breurec, Moustafa Abdel Hafiz, Claudio Eligio Calosso +2 more

We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•May 29, 2025•4 citations

A compact coherent population trapping clock with a short-term fractional frequency stability of 4.2 x 10-13 τ-1/2

Peter Yun, Claudio Eligio Calosso, François Tricot +3 more

Based on the constructive polarization modulation coherent population trapping, we demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 4.2 x 10-13 ?-1/2 up to the averaging time of 100 seconds. This high performance and compact CPT atomic clock would lead more applications which concern on both the frequency stability and the compactness.

International Conference on Space Optics (ICSO)•Sep 25, 2017•0 citations

An atomic clock based on a VCSEL-driven CPT resonance and a small 87Rb vapor cell

Matan Kahanov, Ido Ben-Aroya, G. Eisenstein

We report a high performance frequency standard based on Coherent Population Trapping, incited by a modulated VCSEL in the87Rb-D2line. Short-term stabilities of σy=3×10-11/√τ and relative frequency deviations below 10-11/day were demonstrated.

Quantum Electronics and Laser Science Conference•May 1, 2007•1 citation
We present a compact physics package based on coherent population trapping (CPT) in rubidium 85. The architecture of the package is described along with results obtained using optical- and microwave spectroscopy. We also report the stability of the CPT resonance to variations in operating parameters such as microwave modulation power and vapour cell temperature. With this package we obtain a short term frequency stability σy(τ) = 7·10-11·τ-1/2(τy(τ) ~ 1·10-11( 100 sec4sec).
This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.
We demonstrate a microfabricated atomic clock physics package based on coherent population trapping (CPT) on the D1 line of 87Rb atoms. The package occupies a volume of 12 mm3 and requires 195 mW of power to operate at an ambient temperature of 200 degrees C. Compared to a previous microfabricated clock exciting the D2 transition in Cs [1], this 87Rb clock shows significantly improved short- and long-term stability. The instability at short times is 4 x?10-11 / tau?/2 and the improvement over the Cs device is due mainly to an increase in resonance amplitude. At longer times (tau?> 50 s), the improvement results from the reduction of a slow drift to ?5 x 10-9 / day. The drift is most likely caused by a chemical reaction of nitrogen and barium inside the cell. When probing the atoms on the D1 line, spin-exchange collisions between Rb atoms and optical pumping appear to have increased importance compared to the D2 line.
An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.
We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.