Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Space Optics (ICSO)

A compact coherent population trapping clock with a short-term fractional frequency stability of 4.2 x 10-13 τ-1/2

Peter Yun, Claudio Eligio Calosso, François Tricot, Salvatore Micalizio, Emeric de Clercq, Stéphane Guérandel

Published Sep 25, 2017• 0 citations
Publisher

Abstract

Based on the constructive polarization modulation coherent population trapping, we demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 4.2 x 10-13 ?-1/2 up to the averaging time of 100 seconds. This high performance and compact CPT atomic clock would lead more applications which concern on both the frequency stability and the compactness.

DOI
10.1117/12.2296056

Related papers

Double-Modulation Coherent Population Trapping Clock

Peter Yun, François Tricot, Claudio Eligio Calosso +5 more

Atomic clocks based on coherent population trapping and constructive polarization modulation are promising for high performance and compact devices. We have demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 3. \pmb2×10-13/√{τ} for a few 100 s integration time. This Double-Modulation CPT technology can be reduced to a miniature and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.

Conference on Precision Electromagnetic Measurements•Jul 1, 2018•0 citations

Feasibility toward a compact high performance coherent population trapping clock

Peter Yun, François Tricot, Emeric de Clercq +4 more

We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.

•Apr 14, 2019•0 citations

Frequency biases in a cold-atom coherent population trapping clock

Elizabeth A. Donley, E. Blanshan, François-Xavier Esnault +1 more

A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•2 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•6 citations

High performance compact atomic clock based on coherent population trapping

Stéphane Guérandel, Jean-Marie Danet, Peter Yun +1 more

This paper reports on our best performance achieved with a laboratory compact CPT caesium clock. The device is working in a pulsed regime with orthogonal linear polarizations arranged in the so-called double-lambda configuration using two separate phase-locked lasers tuned to the D1 line. The short term frequency stability has been measured at the level of 3.2×10−13τ−1/2. The mid-term stability is limited at a few 10−14after hundreds of seconds. The main noise sources impacting both short and mid terms are presented and discussed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•4 citations

Studies on the mid-term effects of the double-modulation CPT clock

Alexandre Bouvier, Claudio Eligio Calosso, Peter Yun +2 more

We present recent studies on a continuous compact atomic clock based on the double modulation coherent 1 population trapping (DM-CPT) technique. A short term frequency stability of 2.9x10-13τ-1/2 up to 100 s averaging time is reported. A new technique and time sequence in order to gain in stability in the 1000 s is presented, allowing a frequency stability of 2.0x10−13 at this averaging time, which is better by almost an order of magnitude than the previously published results.

International Conference on Space Optics (ICSO)•Jun 11, 2021•1 citation
Based on the constructive polarization modulation coherent population trapping, we demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 4.2 x 10-13 ?-1/2 up to the averaging time of 100 seconds. This high performance and compact CPT atomic clock would lead more applications which concern on both the frequency stability and the compactness.
Atomic clocks based on coherent population trapping and constructive polarization modulation are promising for high performance and compact devices. We have demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 3. \pmb2×10-13/√{τ} for a few 100 s integration time. This Double-Modulation CPT technology can be reduced to a miniature and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.
We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.
A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.
This paper reports on our best performance achieved with a laboratory compact CPT caesium clock. The device is working in a pulsed regime with orthogonal linear polarizations arranged in the so-called double-lambda configuration using two separate phase-locked lasers tuned to the D1 line. The short term frequency stability has been measured at the level of 3.2×10−13τ−1/2. The mid-term stability is limited at a few 10−14after hundreds of seconds. The main noise sources impacting both short and mid terms are presented and discussed.