Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Optica Sinica

New Method for Cold Atom Number Stabilization in Integrating Sphere Cold Atom Clock

王秀梅 Wang Xiumei, 李琳 Li Lin, 孟艳玲 Meng Yanling, 王亚宁 Wang Yaning, 于明圆 Yu Mingyuan, 王欣 Wang Xin, 万金银 Wan Jinyin, 肖玲 Xiao Ling, 成华东 Cheng Huadong, 刘亮 Liu Liang

Published Jan 1, 2017• 0 citations
Publisher
DOI
10.3788/aos201737.0802001

Related papers

Frequency and Intensity Noises of Probe Laser in Integrating Sphere Cold Atom Clock

王秀梅 Wang Xiumei, 孟艳玲 Meng Yanling, 李琳 Li Lin +7 more

Chinese Journal of Lasers•Jan 1, 2017•1 citation

Short term stability limitations in a compact cold atom clock

S. Trémine, Stéphane Guérandel, David Holleville +3 more

•Aug 29, 2005•0 citations

Lifetime Measurement of Cold Atoms in an Integrating Sphere

张文卓, 王旭成, 成华东 +3 more

Chinese Physics Letters•Jan 1, 2009•1 citation

Optical-plus-microwave pumping in a magnetically insensitive state of cold atoms

Yaning Wang, Yanling Meng, Jinyin Wan +5 more

An optical-plus-microwave pumping method is implemented and optimized to pump cold atoms to a magnetically insensitive state in an integrating sphere. This method consists of several optical and microwave pulses with a proper time sequence. The relative population of cold atoms in the Zeeman sublevel $|F=1,{m}_{F}=0\ensuremath{\rangle}$ is tested by measuring the Rabi oscillations and Ramsey fringes with different numbers of optical and microwave pumping pulses, demonstrating that nearly 83% of the cold atoms can be prepared in the clock state. The number of cold atoms in the target state is up to 2.5 times more than that of the optical pumping alone. Thus, the limitation on the stability of an integrating sphere cold-atom clock from atomic noise is estimated to be from $4.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ to $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$. This method is also suitable for other precision measurements with cold atoms.

Physical Review A•Feb 26, 2018•14 citations

Novel scheme to stabilize compact atomic clocks

Michael Hohensee, David H. Phillips, Ronald Lee Walsworth

Bulletin of the American Physical Society•Jun 7, 2007•0 citations

Reaching a few 10-15 long-term stability of integrating sphere cold atom clock

Yaning Wang Yaning Wang, Yan-Ling Meng, Jinyin Wan Jinyin Wan +6 more

We present the long-term stability of the integrating sphere cold atom clock (ISCAC) and analyze its systematic limitations. The relative frequency instability of 2.6×10−15 is reached for an averaging time of 2×105  s. The second-order Zeeman effect and the cavity pulling effect in ISCAC, which would induce the frequency drift from the clock transition, are analyzed. The analytical and experimental results indicate that the cavity pulling effect is the main contribution to the long-term frequency instability of the ISCAC. Further technical improvements to the microwave cavity are also discussed.

Chinese Optics Letters•Jan 1, 2018•4 citations
An optical-plus-microwave pumping method is implemented and optimized to pump cold atoms to a magnetically insensitive state in an integrating sphere. This method consists of several optical and microwave pulses with a proper time sequence. The relative population of cold atoms in the Zeeman sublevel $|F=1,{m}_{F}=0\ensuremath{\rangle}$ is tested by measuring the Rabi oscillations and Ramsey fringes with different numbers of optical and microwave pumping pulses, demonstrating that nearly 83% of the cold atoms can be prepared in the clock state. The number of cold atoms in the target state is up to 2.5 times more than that of the optical pumping alone. Thus, the limitation on the stability of an integrating sphere cold-atom clock from atomic noise is estimated to be from $4.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ to $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$. This method is also suitable for other precision measurements with cold atoms.
We present the long-term stability of the integrating sphere cold atom clock (ISCAC) and analyze its systematic limitations. The relative frequency instability of 2.6×10−15 is reached for an averaging time of 2×105  s. The second-order Zeeman effect and the cavity pulling effect in ISCAC, which would induce the frequency drift from the clock transition, are analyzed. The analytical and experimental results indicate that the cavity pulling effect is the main contribution to the long-term frequency instability of the ISCAC. Further technical improvements to the microwave cavity are also discussed.