Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Optics Letters

Reaching a few 10-15 long-term stability of integrating sphere cold atom clock

Yaning Wang Yaning Wang, Yan-Ling Meng, Jinyin Wan Jinyin Wan, Ling Xiao, Mingyuan Yu, Xin Wang Xin Wang, Xinchuan Ouyang, Hua-Dong Cheng, Liang Liu

Published Jan 1, 2018• 6 citations
Publisher

Abstract

We present the long-term stability of the integrating sphere cold atom clock (ISCAC) and analyze its systematic limitations. The relative frequency instability of 2.6×10−15 is reached for an averaging time of 2×105  s. The second-order Zeeman effect and the cavity pulling effect in ISCAC, which would induce the frequency drift from the clock transition, are analyzed. The analytical and experimental results indicate that the cavity pulling effect is the main contribution to the long-term frequency instability of the ISCAC. Further technical improvements to the microwave cavity are also discussed.

DOI
10.3788/col201816.070201

Related papers

Improvement in medium long-term frequency stability of the integrating sphere cold atom clock

Peng Liu, Hua-Dong Cheng, Yanling Meng +5 more

The medium long-term frequency stability of the integrating sphere cold atom clock was improved. During the clock operation, Rb87 atoms were cooled and manipulated using cooling light diffusely reflected by the inner surface of a microwave cavity in the clock. This light heated the cavity and caused a frequency drift from the resonant frequency of the cavity. Power fluctuations of the cooling light led to atomic density variations in the cavity’s central area, which increased the clock frequency instability through the cavity pulling effect. We overcame these limitations with appropriate solutions. A frequency stability of 3.5×10−15 was achieved when the integrating time τ increased to 2×104 s.

arXiv:1603.01001•Journal of the Optical Society of America B•Jun 8, 2016•11 citations

Rabi pulling effect in a compact cold-atom clock

Haojie Zhao, Bowen Yang, Yuhan Yan +7 more

We theoretically and experimentally investigate the Rabi pulling effect in an integrating sphere cold-atom clock (ISCAC). Rabi pulling in an ISCAC is caused by magnetic-sublevel transitions between hyperfine states and is related to the amplitude of the microwave pulse, the bias magnetic field, and the density distribution of cold atoms. Theoretical analysis shows the Rabi closed-loop scheme reduces microwave power fluctuation sensitivity by two orders compared to the Ramsey scheme. Experimentally, the Rabi closed-loop scheme achieves a long-term frequency stability of $1.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ at an averaging time of $200\phantom{\rule{0.16em}{0ex}}000$ s.

Physical Review A•Nov 24, 2025•0 citations

Development of the integrated integrating sphere cold atom clock*

Mingyuan Yu, Yanling Meng, Meifeng Ye +6 more

We develop an integrated integrating sphere cold atom clock (ISCAC), which mainly consists of physical package, laser system, microwave source, and electronics. This compact system is more stable and reliable than the previous version. The experimental results show that the short term frequency stability of 5.4 × 10 − 13 τ − 1 / 2 and 2.9 × 10−15 at 1-day integrating time are achieved.

Chinese Physics B•Jul 1, 2019•10 citations

Estimation of instability induced by probe laser frequency noise in cold-atom microwave clocks

Bowen Yang, Haojie Zhao, Ling Xiao +3 more

The influence of laser frequency noise on the stability of a compact cold-atom microwave clock was investigated theoretically in this study. The phase-noisy laser was characterized by a phase-diffusion field. Given the laser linewidth, the analytical expressions of the atomic covariance function and the noise power spectral density of the relative intensity noise transferred from the frequency noise were derived based on stochastic differential equations. Our results provide an effective method to estimate the impact of laser frequency noise on the stability of an integrating sphere cold atomic clock. This method can be extended to other cold atom detection cases.

Journal of the Optical Society of America B•Jun 5, 2023•2 citations

Towards an Accuracy Budget of Cold-Atom-Based Commercial Microwave Clocks

Luc Archambault, Floriane Sparma, L. Lorini +4 more

We present results of commercial microwave clocks developed by Exail Quantum Systems (formerly Muquans). The MuClocks are cold-atom-based turnkey products dedicated to continuous long-term operation. A frequency stability of 1×10-15 over more than a month has been demonstrated on several set-ups, competing with the frequency drift (~1×10-16/day) of the best masers. Recent stability evaluations show for the best clock a long-term frequency stability of 7×10-16 over two weeks and for the longest run ~2×10-15 over two months. IIn this contribution, we will present a preliminary accuracy budget, the targeted product accuracy being in the 5×10-15 range. Control and evaluation of the known frequency biases is on-going. Several frequency shifts have already been quantified: the Quadratic Zeeman shift, the cavity pulling including its asymmetry from nearby cavity resonances, microwave phase transients and the Ramsey pulling.

•Jun 25, 2024•0 citations

Cold atom microwave clock based on intracavity cooling in China space station

Siminda Deng, Wei Ren, Jingfeng Xiang +9 more

Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.

npj Microgravity•Jun 6, 2024•15 citations
We present the long-term stability of the integrating sphere cold
atom clock (ISCAC) and analyze its systematic limitations. The relative
frequency instability of 2.6×10−15 is reached for an averaging
time of 2×105  s. The second-order Zeeman effect and the
cavity pulling effect in ISCAC, which would induce the frequency drift
from the clock transition, are analyzed. The analytical and experimental
results indicate that the cavity pulling effect is the main contribution
to the long-term frequency instability of the ISCAC. Further technical
improvements to the microwave cavity are also discussed.
The medium long-term frequency stability of the integrating sphere cold atom clock was improved. During the clock operation, Rb87 atoms were cooled and manipulated using cooling light diffusely reflected by the inner surface of a microwave cavity in the clock. This light heated the cavity and caused a frequency drift from the resonant frequency of the cavity. Power fluctuations of the cooling light led to atomic density variations in the cavity’s central area, which increased the clock frequency instability through the cavity pulling effect. We overcame these limitations with appropriate solutions. A frequency stability of 3.5×10−15 was achieved when the integrating time τ increased to 2×104 s.
We theoretically and experimentally investigate the Rabi pulling effect in an integrating sphere cold-atom clock (ISCAC). Rabi pulling in an ISCAC is caused by magnetic-sublevel transitions between hyperfine states and is related to the amplitude of the microwave pulse, the bias magnetic field, and the density distribution of cold atoms. Theoretical analysis shows the Rabi closed-loop scheme reduces microwave power fluctuation sensitivity by two orders compared to the Ramsey scheme. Experimentally, the Rabi closed-loop scheme achieves a long-term frequency stability of $1.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ at an averaging time of 200000200\phantom{\rule{0.16em}{0ex}}000200000 s.
The influence of laser frequency noise on the stability of a compact cold-atom microwave clock was investigated theoretically in this study. The phase-noisy laser was characterized by a phase-diffusion field. Given the laser linewidth, the analytical expressions of the atomic covariance function and the noise power spectral density of the relative intensity noise transferred from the frequency noise were derived based on stochastic differential equations. Our results provide an effective method to estimate the impact of laser frequency noise on the stability of an integrating sphere cold atomic clock. This method can be extended to other cold atom detection cases.
We present results of commercial microwave clocks developed by Exail Quantum Systems (formerly Muquans). The MuClocks are cold-atom-based turnkey products dedicated to continuous long-term operation. A frequency stability of 1×10-15 over more than a month has been demonstrated on several set-ups, competing with the frequency drift (~1×10-16/day) of the best masers. Recent stability evaluations show for the best clock a long-term frequency stability of 7×10-16 over two weeks and for the longest run ~2×10-15 over two months. IIn this contribution, we will present a preliminary accuracy budget, the targeted product accuracy being in the 5×10-15 range. Control and evaluation of the known frequency biases is on-going. Several frequency shifts have already been quantified: the Quadratic Zeeman shift, the cavity pulling including its asymmetry from nearby cavity resonances, microwave phase transients and the Ramsey pulling.
Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.