Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Tunneling Time, Exit Time and Exit Momentum in Strong Field Tunnel Ionization

Nicolas Teeny

Published Jan 1, 2016• 1 citation
Publisher

Abstract

Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schr{\\"o}dinger equation in one and two dimensions and use \\textit{ab initio} quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.

DOI
10.11588/heidok.00022016

Related papers

Salecker-Wigner-Peres quantum clock applied to strong-field tunnel ionization

Nicolas Teeny, Christoph H. Keitel, Heiko Bauke

The Salecker-Wigner-Peres quantum-clock approach is applied in order to determine the tunneling time of an electron in strong-field tunnel ionization via a time-dependent electric field. Our results show that the ionization of the electron takes a nonvanishing period of time. This tunneling time is of the order of the Keldysh time but strictly larger than the Keldysh time. Comparing the quantum-clock tunneling time to the mean tunneling time as obtained by the virtual-detector approach, one finds that these two complementary methods give very similar results. Due to the asymmetric distribution of the tunneling time, there is a nonnegligible discrepancy between the mean tunneling time and the most probable tunneling time.

arXiv:1608.02854•Aug 9, 2016•2 citations

Distribution of ionization and tunneling times in a model of strong field ionization

Jose Tadeu Lunardi, Luiz A. Manzoni

Abstract We consider a simple model for strong field ionization and use the Salecker-Wigner-Peres clock to obtain a distribution of (real) times associated with this phenomenon. By coupling the Salecker-Wigner-Peres clock to the particle in different regions, we are able to distinguish between the ionization (exit) time, the tunneling time and the time the particle spends in the well before entering the barrier (the well time). We show that the distribution of ionization/exit times, which are the times usually measured in attoclock experiments, may differ significantly from the distribution of tunneling times, suggesting that the ionization times cannot be generally interpreted as tunneling times.

Journal of Physics Conference Series•Nov 1, 2019•1 citation

Quantum tunnelling time at long wavelengths

Zheng Shu, Da-Wei Tian, Jing-Yu Zhang +3 more

Abstract Quantum tunnelling is a fundamental phenomenon in quantum physics, yet the question of how long it takes for a particle to tunnel through a barrier remains a topic of ongoing debate. Recent advances in attoclock experimental techniques in strong-field physics have renewed interest in this topic. While various definitions of tunneling time have been proposed, a consensus has yet to be reached. In this study, we adopt a definition of tunnelling time based on the ratio of the barrier width to the expected value of the velocity operator within the barrier. This approach reduces to the Büttiker-Landauer time ($\tau_{BL}$) in the case of an opaque barrier and offers a clear physical interpretation for very thin barriers, where $\tau_{BL}$ may not be well-defined. Additionally, by utilizing a virtual detector at the tunnel exit, we calculate the time delay between the peak of the electric field and the moment of ionization for long wavelengths ($\geq$6 $\mu$m). Our findings indicate that the time delay stabilizes around 190 as, remaining independent of the laser wavelength. Furthermore, through our quantum tunnelling time definition, this time delay can be interpreted as the time required for the electron to tunnel from a point within the barrier to the exit.

Chinese Physics B•Mar 12, 2026•0 citations

Dynamics of tunneling ionization using Bohmian mechanics

Nicolas Douguet, Klaus Bartschat

Recent attoclock experiments and theoretical studies regarding the strong-field ionization of atoms by few-cycle infrared pulses revealed features that have attracted much attention. Here we investigate tunneling ionization and the dynamics of the electron probability using Bohmian mechanics. We consider a one-dimensional problem to illustrate the underlying mechanisms of the ionization process. It is revealed that in the major part of the below-the-barrier ionization regime, in an intense and short infrared pulse, the electron does not tunnel through the entire barrier, but rather starts already from the classically forbidden region. Moreover, we highlight the correspondence between the probability of locating the electron at a particular initial position and its asymptotic momentum. Bohmian mechanics also provides a natural definition of mean tunneling time and exit position, taking account of the time dependence of the barrier. Finally, we find that the electron can exit the barrier with significant kinetic energy, thereby corroborating the results of a recent study [N. Camus et al., Phys. Rev. Lett. 119, 023201 (2017)].

arXiv:1712.07100•Physical Review A•Jan 8, 2018•46 citations

Tunneling Time and Weak Measurement in Strong Field Ionization

Tomáš Zimmermann, Siddhartha Mishra, Brent Doran +2 more

Tunneling delays represent a hotly debated topic, with many conflicting definitions and little consensus on when and if such definitions accurately describe the physical observables. Here, we relate these different definitions to distinct experimental observables in strong field ionization, finding that two definitions, Larmor time and Bohmian time, are compatible with the attoclock observable and the resonance lifetime of a bound state, respectively. Both of these definitions are closely connected to the theory of weak measurement, with Larmor time being the weak measurement value of tunneling time and Bohmian trajectory corresponding to the average particle trajectory, which has been recently reconstructed using weak measurement in a two-slit experiment [S. Kocsis, B. Braverman, S. Ravets, M. J. Stevens, R. P. Mirin, L. K. Shalm, and A. M. Steinberg, Science 332, 1170 (2011)]. We demonstrate a big discrepancy in strong field ionization between the Bohmian and weak measurement values of tunneling time, and we suggest this arises because the tunneling time is calculated for a small probability postselected ensemble of electrons. Our results have important implications for the interpretation of experiments in attosecond science, suggesting that tunneling is unlikely to be an instantaneous process.

Physical Review Letters•Jun 10, 2016•112 citations

The quantum superluminality in the tunnel-ionization process of H-like atoms

Ossama Kullie, Igor A. Ivanov

The quantum tunneling time remains the subject of heated debate, and one of its most curious features is faster-than-light or superluminal tunneling. Our tunnel-ionization model of the time-delay, presented in previous work, shows good agreement with the attoclock measurement in the adiabatic and nonadiabatic field calibrations, which also enables the determination of the barrier time-delay. In the present work, we show that the tunnel-ionization for H-like atoms with large nuclear charge can be superluminal (quantum superluminality), which in principle can be investigated experimentally using the attoclock scheme. We discuss the quantum superluminality in detail for the different regimes of the tunnel-ionization. Our result shows that quantum tunneling faster-than-light is indeed possible, albeit only under somewhat extreme conditions.

quant-pharXiv:2602.20106•Feb 24, 2026•0 citations
Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schr{\"o}dinger equation in one and two dimensions and use \textit{ab initio} quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.
The Salecker-Wigner-Peres quantum-clock approach is applied in order to determine the tunneling time of an electron in strong-field tunnel ionization via a time-dependent electric field. Our results show that the ionization of the electron takes a nonvanishing period of time. This tunneling time is of the order of the Keldysh time but strictly larger than the Keldysh time. Comparing the quantum-clock tunneling time to the mean tunneling time as obtained by the virtual-detector approach, one finds that these two complementary methods give very similar results. Due to the asymmetric distribution of the tunneling time, there is a nonnegligible discrepancy between the mean tunneling time and the most probable tunneling time.
Abstract We consider a simple model for strong field ionization and use the Salecker-Wigner-Peres clock to obtain a distribution of (real) times associated with this phenomenon. By coupling the Salecker-Wigner-Peres clock to the particle in different regions, we are able to distinguish between the ionization (exit) time, the tunneling time and the time the particle spends in the well before entering the barrier (the well time). We show that the distribution of ionization/exit times, which are the times usually measured in attoclock experiments, may differ significantly from the distribution of tunneling times, suggesting that the ionization times cannot be generally interpreted as tunneling times.
Abstract Quantum tunnelling is a fundamental phenomenon in quantum physics, yet the question of how long it takes for a particle to tunnel through a barrier remains a topic of ongoing debate. Recent advances in attoclock experimental techniques in strong-field physics have renewed interest in this topic. While various definitions of tunneling time have been proposed, a consensus has yet to be reached. In this study, we adopt a definition of tunnelling time based on the ratio of the barrier width to the expected value of the velocity operator within the barrier. This approach reduces to the Büttiker-Landauer time (τBL\tau_{BL}τBL​) in the case of an opaque barrier and offers a clear physical interpretation for very thin barriers, where τBL\tau_{BL}τBL​ may not be well-defined. Additionally, by utilizing a virtual detector at the tunnel exit, we calculate the time delay between the peak of the electric field and the moment of ionization for long wavelengths ($\geq$6 μ\muμm). Our findings indicate that the time delay stabilizes around 190 as, remaining independent of the laser wavelength. Furthermore, through our quantum tunnelling time definition, this time delay can be interpreted as the time required for the electron to tunnel from a point within the barrier to the exit.
Recent attoclock experiments and theoretical studies regarding the strong-field ionization of atoms by few-cycle infrared pulses revealed features that have attracted much attention. Here we investigate tunneling ionization and the dynamics of the electron probability using Bohmian mechanics. We consider a one-dimensional problem to illustrate the underlying mechanisms of the ionization process. It is revealed that in the major part of the below-the-barrier ionization regime, in an intense and short infrared pulse, the electron does not tunnel through the entire barrier, but rather starts already from the classically forbidden region. Moreover, we highlight the correspondence between the probability of locating the electron at a particular initial position and its asymptotic momentum. Bohmian mechanics also provides a natural definition of mean tunneling time and exit position, taking account of the time dependence of the barrier. Finally, we find that the electron can exit the barrier with significant kinetic energy, thereby corroborating the results of a recent study [N. Camus et al., Phys. Rev. Lett. 119, 023201 (2017)].
Tunneling delays represent a hotly debated topic, with many conflicting definitions and little consensus on when and if such definitions accurately describe the physical observables. Here, we relate these different definitions to distinct experimental observables in strong field ionization, finding that two definitions, Larmor time and Bohmian time, are compatible with the attoclock observable and the resonance lifetime of a bound state, respectively. Both of these definitions are closely connected to the theory of weak measurement, with Larmor time being the weak measurement value of tunneling time and Bohmian trajectory corresponding to the average particle trajectory, which has been recently reconstructed using weak measurement in a two-slit experiment [S. Kocsis, B. Braverman, S. Ravets, M. J. Stevens, R. P. Mirin, L. K. Shalm, and A. M. Steinberg, Science 332, 1170 (2011)]. We demonstrate a big discrepancy in strong field ionization between the Bohmian and weak measurement values of tunneling time, and we suggest this arises because the tunneling time is calculated for a small probability postselected ensemble of electrons. Our results have important implications for the interpretation of experiments in attosecond science, suggesting that tunneling is unlikely to be an instantaneous process.
The quantum tunneling time remains the subject of heated debate, and one of its most curious features is faster-than-light or superluminal tunneling. Our tunnel-ionization model of the time-delay, presented in previous work, shows good agreement with the attoclock measurement in the adiabatic and nonadiabatic field calibrations, which also enables the determination of the barrier time-delay. In the present work, we show that the tunnel-ionization for H-like atoms with large nuclear charge can be superluminal (quantum superluminality), which in principle can be investigated experimentally using the attoclock scheme. We discuss the quantum superluminality in detail for the different regimes of the tunnel-ionization. Our result shows that quantum tunneling faster-than-light is indeed possible, albeit only under somewhat extreme conditions.