Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Zeeman spectrum and magnetic effect of trapped 199Hg+ ions

黄雄, 杨玉娜, 柳浩, 高克林, 佘磊, 李交美

Published Jan 1, 2010• 0 citations
OpenAlex

Related papers

Ion-number-density-dependent effects on hyperfine transition of trapped 199Hg+ ions in quadrupole linear ion traps

Zhi-Hui Yang, Yi-He Chen, Bibo Yan +5 more

Physics Letters A•Feb 7, 2017•2 citations

A Cryogenic Linear Ion Trap for 199Hg+ Frequency Standards

J.D. Miller, Martin E. Poitzsch, Flávio C. Cruz +4 more

•Jan 1, 1996•2 citations

Measurement of the hyperfine structure Zeeman splitting of the Hg+ ion

Hans A. Schuessler, Sigmund John Hoverson

Physics Letters A•Feb 1, 1973•3 citations

Zeeman decoherence effect of trapped 199Hg+ ion Ramsey spectra

Ge 格 Liu 刘, Hao Liu, Yi-He Chen +4 more

Abstract In the 199Hg+ ion microwave clock, the Zeeman decoherence effect caused by the overlapping of Zeeman sidebands and the radial secular motion sidebands will decrease the contrast of the Ramsey fringe, thus reducing the signal-to-noise ratio of the spectra. In this paper, the Zeeman decoherence effect is analyzed theoretically and investigated experimentally. A simplified model is built to describe the Ramsey spectral probability, in which the transverse relaxation time T 2 is introduced to characterize the influence of the Zeeman decoherence effect phenomenologically. The experiments were carried out on a linear quadrupole trap 199Hg+ ion clock. The results show that the probability model matches well with the experimental data, and the magnetic field value should be more than 150 mGs (1 Gs = 10−4 T) to avoid the Zeeman decoherence effect.

Chinese Physics B•Sep 14, 2024•1 citation

Zeeman Effect of the Hyperfine Structure Components of the Mercury Resonance Line 2537 A

A. VIRONAS

Nature•Mar 28, 1936•0 citations

Magnetic Trapping and Zeeman Relaxation of NH Molecules

Edem Tsikata, Wesley C. Campbell, Hsin-I Lu +2 more

Bulletin of the American Physical Society•May 29, 2008•0 citations
Abstract In the 199Hg+ ion microwave clock, the Zeeman decoherence effect caused by the overlapping of Zeeman sidebands and the radial secular motion sidebands will decrease the contrast of the Ramsey fringe, thus reducing the signal-to-noise ratio of the spectra. In this paper, the Zeeman decoherence effect is analyzed theoretically and investigated experimentally. A simplified model is built to describe the Ramsey spectral probability, in which the transverse relaxation time T 2 is introduced to characterize the influence of the Zeeman decoherence effect phenomenologically. The experiments were carried out on a linear quadrupole trap 199Hg+ ion clock. The results show that the probability model matches well with the experimental data, and the magnetic field value should be more than 150 mGs (1 Gs = 10−4 T) to avoid the Zeeman decoherence effect.