Journal of Optoelectronics·laser

Light Frequency Shift in a Cesium Beam Frequency Standard with Sharp Angle Incident Laser Light Pumping

Yiqiu Wang

Published Jan 1, 2001• 0 citations
OpenAlex

Abstract

In the experimental system of the small cesium beam frequency standard with sharp angle incident laser light pumping and sharp angle incident laser light probing,the light frequency shift (mainly caused by AC Stark effect) caused by fluorescence from pumping region was calculated theoretically.The results show,the light frequency shift can be effectively reduced in the sharp angle laser light pumping scheme.In additon,a new method to measure the light frequency shift by changing the diffusing angle of the pumping laser light beam was presented in this paper.

Related papers

Chirping removes recoil effect on fluorescence signal of optical pumping by synchronous frequency modulation

Samaneh Birzhandi

Abstract Recoil effect is one of the limiting factors of signal amplitude in many spectroscopic applications due to creating light shift or AC Stark effect. Doppler shift of the Recoil velocity of the pumped atoms reduces their absorption efficiency. Synchronous Frequency Modulation or chirping of the pump laser enhances optical pumping and amplitude of the fluorescence signal. Results of this paper demonstrate significant enhancement of the fluorescence signal and the symmetry of the signal.

Engineering Research Express•Sep 1, 2021•1 citation

Frequency stability performance of a laser pumped rubidium vapor cell atomic frequency standard

M. Zhu

The AC Stark shift (the light shift) is very important in the performance of laser-pumped vapor cell atomic frequency standards. The frequency stability of a compact rubidium vapor cell atomic frequency standard with an AC Stark shift suppression laser pumping method was evaluated. The applications of such a device include serving as primary reference clocks in communication systems such as Stratum 1 reference clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation

Theoretical and Experimental Study of Light Shift in a CPT-Based RB Vapor Cell Frequency Standard

Meng Tong Zhu, Leonard S. Cutler

One of the important subjects in coherent-population- trapping-based (CPT-based) vapor cell frequency standards is the light shift (ac Stark shift). We calculate the light shift using a numerical method and perturbation approximation. Experimentally, we measure light shift using a pair of phase-locked diode lasers as well as a frequency-modulated diode laser. There is good agreement between theory and experiment. A method of controlling light shift in CPT-based frequency standards is proposed and implemented in Agilent Laboratories. The short-term stability of our CPT-based rubidium vapor cell frequency standard is measured as 1.3 x 10(-12) tau (-1/2), which is limited by the phase noise of the reference local oscillator used.

•Jan 1, 2001•51 citations

Laser nonuniformity and ac Stark shift effect on two-photon resonant three-photon ionization process of cesium atom

Jonghoon Yi, Hyunmin Park, Jaemin Han +3 more

Summary form only given. We investigated the effect of temporal and spatial characteristics not only on the ionization spectrum but on the excited-state population. From the calculational results in which Gaussian temporal and spatial variation was assumed, it was found that the nonuniformity of a laser made the shift of ionization peak frequency different from that of excitation peak frequency. This result indicates that measurement of an ac Stark shift cross section by detecting the fluorescence emitted from an excited state might give the different results comparing with the ionization spectrum measurement case.

Conference on Lasers and Electro-Optics•Nov 27, 2002•0 citations

Laser cooling of a cesium beam utilizing Stark effect frequency compensation

Jeng-Rong Yeh, Barbara M. Hoeling, R. J. Knize

Laser cooling of neutral atoms has possible applications such as better frequency standards and high precision spectroscopy. It would be desirable to produce a cold continuous beam of atoms with small transverse velocity to be used in atomic fountains and collision studies. One method to produce a cold continuous beam uses Zeeman effect to compensate the Doppler shift as atoms are slowed. We present a new method for producing a cold Cesium beam using Stark effect frequency tuning.

•May 8, 1994•0 citations

Reducing light-shift effects in optically-pumped gas-cell atomic frequency standards

C. Affolderbach, G. Mileti, C. Andreeva +3 more

We investigate a novel method to suppress the light-shift effect in laser-pumped passive rubidium frequency standards. The reduction of the light-shift due to additional frequency components in the pumping light is studied theoretically and compared to experimental results obtained with a frequency-modulated DBR laser diode as a pumping light source. In this way, a reduction of the light shift by a factor of 55 was successfully demonstrated. Complete cancellation of the light shift can be reached with a suitably adjusted modulation index and frequency.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 8, 2004•5 citations
In the experimental system of the small cesium beam frequency standard with sharp angle incident laser light pumping and sharp angle incident laser light probing,the light frequency shift (mainly caused by AC Stark effect) caused by fluorescence from pumping region was calculated theoretically.The results show,the light frequency shift can be effectively reduced in the sharp angle laser light pumping scheme.In additon,a new method to measure the light frequency shift by changing the diffusing angle of the pumping laser light beam was presented in this paper.
One of the important subjects in coherent-population- trapping-based (CPT-based) vapor cell frequency standards is the light shift (ac Stark shift). We calculate the light shift using a numerical method and perturbation approximation. Experimentally, we measure light shift using a pair of phase-locked diode lasers as well as a frequency-modulated diode laser. There is good agreement between theory and experiment. A method of controlling light shift in CPT-based frequency standards is proposed and implemented in Agilent Laboratories. The short-term stability of our CPT-based rubidium vapor cell frequency standard is measured as 1.3 x 10(-12) tau (-1/2), which is limited by the phase noise of the reference local oscillator used.
Summary form only given. We investigated the effect of temporal and spatial characteristics not only on the ionization spectrum but on the excited-state population. From the calculational results in which Gaussian temporal and spatial variation was assumed, it was found that the nonuniformity of a laser made the shift of ionization peak frequency different from that of excitation peak frequency. This result indicates that measurement of an ac Stark shift cross section by detecting the fluorescence emitted from an excited state might give the different results comparing with the ionization spectrum measurement case.
We investigate a novel method to suppress the light-shift effect in laser-pumped passive rubidium frequency standards. The reduction of the light-shift due to additional frequency components in the pumping light is studied theoretically and compared to experimental results obtained with a frequency-modulated DBR laser diode as a pumping light source. In this way, a reduction of the light shift by a factor of 55 was successfully demonstrated. Complete cancellation of the light shift can be reached with a suitably adjusted modulation index and frequency.