Acta Physica Sinica

MICROMASER INJECTED WITH ULTRA-COLD V-TYPE THREE-LEVEL ATOMS:EFFECTS OF ATOMIC COHERENCE ON PHOTON STATISTICS

Liang Wen-Qing, Chu Kai-Qin, Zhi‐Ming Zhang, Sheng-Wu Xie, 上海交通大学物理系,上海200240

Published Jan 1, 2001• 2 citations
Publisher

Abstract

The effects of the atomic coherence on the photon statistics of the micromaser injected with ultra-cold V-type three-level atoms are studied.In the plot of the atomic emission probability versus the cavity length, there are resonance peaks and non-resonance platforms, which can be adjusted by the atomic coherence parameters.These features of emission probability affect the properties of photon statistics directly. In the plot of the mean number of photons versus the cavity length, there are resonance peaks and non-resonance platforms,too. Given a cavity length, with the change of the atomic coherence parameters, the distribution of photon numbers can move towards the large or small photon numbers, and the mean number of photons increases or decreases accordingly.We also find, with appropriate atomic coherence parameters, that the photon statistics are sub-Poissonian in large region of the cavity length.

DOI
10.7498/aps.50.2345

Related papers

Photon statistics of the micromaser with ultra cold Λ-type three-level atoms

Zhang Zhi-ming, LI Xian-feng, Zhou Shi-kang

We have established the master equation for the micromaser with the ultra-cold Λ-type three-level atoms and studied the photon statistics of the micromaser field. We find that as the atoms become colder, the change of the mean photon-number and the normalized standard deviation become more regular, and their resonance peaks become sharper. For zero-temperature cavity, there are some regions in which the photon statistics are sub-Poissonian. With the increase of the cavity temperature, both the mean photon-number and the normalized standard deviation increase. When the cavity temperature is high enough, the sub-Poissonian property may disappear.

Acta Physica Sinica (Overseas Edition)•Aug 1, 1999•5 citations

Transmission probability of the two-mode mazer with injected atomic coherence

Chun-Hua Yuan, Zhi‐Ming Zhang

The transmission probability of the two-mode mazer injected with V-type three-level atoms is studied and the effects of the atomic coherence on it are examined. It is shown that the atomic coherence can affect the transmission probability. In the plots of the atomic transmission probability versus the dimensionless centre-of-mass momentum, there are resonance peaks and non-resonance platforms. The heights of these resonance peaks and non-resonance platforms can be adjusted by the atomic coherence parameter and by the relative coupling strength of the two transition channels.

Chinese Physics•Dec 23, 2004•1 citation

On single-mode - and V-type micromasers: quantum interference versus photon statistics

Si-de Du, Yoshitaka Tanimura

Quantum interference effects are theoretically investigated in the steady-state photon statistics of single-mode Λ- and V-type micromasers with injected three-level atoms in a superposition of their internal states. The two lower (upper) levels are nondegenerate and coherent in a general case. For the Λ-type case, we have discussed how detunings affect the photon statistics of the noninversion micromaser. Under the proper conditions strongly sub-Poissonian field states with a large number of photons can be easily produced in this novel micromaser even if there exists no coherence between the two lower levels. For the V-type case, we have analysed how the photon statistics changes with the increase of the ground-state population. Although the generation of the strongly sub-Poissonian states is always possible in the micromaser under the noninversion case, their photon intensities become very weak compared to the Λ-type case. Our results indicate that it is perfectly possible to experimentally realize a noninversion micromaser with strongly sub-Poissonian statistics in the Λ-type system.

Journal of Optics B Quantum and Semiclassical Optics•Oct 18, 2002•9 citations

Atomic Coherence in the Micromaser Injected with Slow V-type Three-State Atoms: Emission Probability

Zhi‐Ming Zhang, Liang Wen-Qing, Sheng-Wu Xie

The effects of atomic coherence on the single-mode two-photon micromaser injected with slow V-type three-state atoms are studied for the first time. It is shown that the atomic coherence can modify the atomic emission probability. The effects of the atomic centre-of-mass momentum, the cavity length and other parameters are also studied.

Chinese Physics Letters•Feb 1, 2001•12 citations

Quantum theory of the micromaser with ultra-cold cascade three-level atoms

Zhi‐Ming Zhang, Sheng-Wu Xie, Shikang Zhou

We derive the dressed states for the interaction of a cascade three-level atom with a quantum cavity field, suggest using ultra-cold cascade three-level atoms in micromasers, put forward the idea of the two-photon mazer, establish its general quantum theory and study its emission probability and photon statistics. We examine the effects of the atomic centre-of-mass momentum, the atom-field detuning, the photon number in thermal equilibrium, the ratio of the atomic injection rate to the cavity decay rate and the interaction length on the emission probability and the photon statistics.

Journal of Physics B Atomic Molecular and Optical Physics•Aug 13, 1999•10 citations

Emission Probability of the Cascade Three-Level-Atom Mazer with Injected Atomic Coherence

Jin Xiong, Zhi‐Ming Zhang

We investigate the effects of the injected atomic coherence on the atomic emission probability of the micromaser injected with ultracold cascade three-level atoms by considering that the atoms are initially in the coherent superposition states of the two upper levels. We show that there is no interference between the transitions from the two upper levels to the lowest level. In the large atom-field-detuning case, the atomic emission probability decreases as the coherent parameter increases. In the zero atom-field-detuning case, the atomic emission probability has three sets of resonance peaks. The reason for these results has been explained.

Chinese Physics Letters•Nov 1, 2002•7 citations
The effects of the atomic coherence on the photon statistics of the micromaser injected with ultra-cold V-type three-level atoms are studied.In the plot of the atomic emission probability versus the cavity length, there are resonance peaks and non-resonance platforms, which can be adjusted by the atomic coherence parameters.These features of emission probability affect the properties of photon statistics directly. In the plot of the mean number of photons versus the cavity length, there are resonance peaks and non-resonance platforms,too. Given a cavity length, with the change of the atomic coherence parameters, the distribution of photon numbers can move towards the large or small photon numbers, and the mean number of photons increases or decreases accordingly.We also find, with appropriate atomic coherence parameters, that the photon statistics are sub-Poissonian in large region of the cavity length.
We have established the master equation for the micromaser with the ultra-cold Λ-type three-level atoms and studied the photon statistics of the micromaser field. We find that as the atoms become colder, the change of the mean photon-number and the normalized standard deviation become more regular, and their resonance peaks become sharper. For zero-temperature cavity, there are some regions in which the photon statistics are sub-Poissonian. With the increase of the cavity temperature, both the mean photon-number and the normalized standard deviation increase. When the cavity temperature is high enough, the sub-Poissonian property may disappear.
The transmission probability of the two-mode mazer injected with V-type three-level atoms is studied and the effects of the atomic coherence on it are examined. It is shown that the atomic coherence can affect the transmission probability. In the plots of the atomic transmission probability versus the dimensionless centre-of-mass momentum, there are resonance peaks and non-resonance platforms. The heights of these resonance peaks and non-resonance platforms can be adjusted by the atomic coherence parameter and by the relative coupling strength of the two transition channels.
Quantum interference effects are theoretically investigated in the steady-state photon statistics of single-mode Λ- and V-type micromasers with injected three-level atoms in a superposition of their internal states. The two lower (upper) levels are nondegenerate and coherent in a general case. For the Λ-type case, we have discussed how detunings affect the photon statistics of the noninversion micromaser. Under the proper conditions strongly sub-Poissonian field states with a large number of photons can be easily produced in this novel micromaser even if there exists no coherence between the two lower levels. For the V-type case, we have analysed how the photon statistics changes with the increase of the ground-state population. Although the generation of the strongly sub-Poissonian states is always possible in the micromaser under the noninversion case, their photon intensities become very weak compared to the Λ-type case. Our results indicate that it is perfectly possible to experimentally realize a noninversion micromaser with strongly sub-Poissonian statistics in the Λ-type system.
We derive the dressed states for the interaction of a cascade three-level atom with a quantum cavity field, suggest using ultra-cold cascade three-level atoms in micromasers, put forward the idea of the two-photon mazer, establish its general quantum theory and study its emission probability and photon statistics. We examine the effects of the atomic centre-of-mass momentum, the atom-field detuning, the photon number in thermal equilibrium, the ratio of the atomic injection rate to the cavity decay rate and the interaction length on the emission probability and the photon statistics.
We investigate the effects of the injected atomic coherence on the atomic emission probability of the micromaser injected with ultracold cascade three-level atoms by considering that the atoms are initially in the coherent superposition states of the two upper levels. We show that there is no interference between the transitions from the two upper levels to the lowest level. In the large atom-field-detuning case, the atomic emission probability decreases as the coherent parameter increases. In the zero atom-field-detuning case, the atomic emission probability has three sets of resonance peaks. The reason for these results has been explained.