Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics

Transmission probability of the two-mode mazer with injected atomic coherence

Chun-Hua Yuan, Zhi‐Ming Zhang

Published Dec 23, 2004• 1 citation
Publisher

Abstract

The transmission probability of the two-mode mazer injected with V-type three-level atoms is studied and the effects of the atomic coherence on it are examined. It is shown that the atomic coherence can affect the transmission probability. In the plots of the atomic transmission probability versus the dimensionless centre-of-mass momentum, there are resonance peaks and non-resonance platforms. The heights of these resonance peaks and non-resonance platforms can be adjusted by the atomic coherence parameter and by the relative coupling strength of the two transition channels.

DOI
10.1088/1009-1963/14/1/026

Related papers

V-type three-level-atom mazer with atomic coherence: velocity selection

Liang Wen-Qing, Niu Zhong-qi, Zhi-Ming Zhang +1 more

The velocity selection of the V-type three-level-atom mazer with atomic coherence is studied. It is shown that the atomic coherence can strongly affect transmission probability, and in turn, the velocity selection of atoms through the micromaser cavity. When the incident atoms are initially prepared in the lower state of the two upper ones (i.e., no injected atomic coherence), velocity selectivity is at a maximum. This shows that atomic coherence does not have a favourable effect on velocity selectivity in this scheme. The effects of other parameters are also studied.

Journal of Physics B Atomic Molecular and Optical Physics•Nov 13, 2001•3 citations

Emission Probability of the Cascade Three-Level-Atom Mazer with Injected Atomic Coherence

Jin Xiong, Zhi‐Ming Zhang

We investigate the effects of the injected atomic coherence on the atomic emission probability of the micromaser injected with ultracold cascade three-level atoms by considering that the atoms are initially in the coherent superposition states of the two upper levels. We show that there is no interference between the transitions from the two upper levels to the lowest level. In the large atom-field-detuning case, the atomic emission probability decreases as the coherent parameter increases. In the zero atom-field-detuning case, the atomic emission probability has three sets of resonance peaks. The reason for these results has been explained.

Chinese Physics Letters•Nov 1, 2002•7 citations

MICROMASER INJECTED WITH ULTRA-COLD V-TYPE THREE-LEVEL ATOMS:EFFECTS OF ATOMIC COHERENCE ON PHOTON STATISTICS

Liang Wen-Qing, Chu Kai-Qin, Zhi‐Ming Zhang +2 more

The effects of the atomic coherence on the photon statistics of the micromaser injected with ultra-cold V-type three-level atoms are studied.In the plot of the atomic emission probability versus the cavity length, there are resonance peaks and non-resonance platforms, which can be adjusted by the atomic coherence parameters.These features of emission probability affect the properties of photon statistics directly. In the plot of the mean number of photons versus the cavity length, there are resonance peaks and non-resonance platforms,too. Given a cavity length, with the change of the atomic coherence parameters, the distribution of photon numbers can move towards the large or small photon numbers, and the mean number of photons increases or decreases accordingly.We also find, with appropriate atomic coherence parameters, that the photon statistics are sub-Poissonian in large region of the cavity length.

Acta Physica Sinica•Jan 1, 2001•2 citations

Atomic Coherence in the Micromaser Injected with Slow V-type Three-State Atoms: Emission Probability

Zhi‐Ming Zhang, Liang Wen-Qing, Sheng-Wu Xie

The effects of atomic coherence on the single-mode two-photon micromaser injected with slow V-type three-state atoms are studied for the first time. It is shown that the atomic coherence can modify the atomic emission probability. The effects of the atomic centre-of-mass momentum, the cavity length and other parameters are also studied.

Chinese Physics Letters•Feb 1, 2001•12 citations

Emission Probability of the Cascade Three—Level—Atom Mazer with Injected Atomic Coherence

熊锦, 张智明

We investigate the effects of the injected atomic coherence on the atomic emission probability of the micromaser injected with ultracold cascade three-level atoms by considering that the atoms are initially in the coherent superposition states of the two upper levels,we show that there is no interference between the transitions from the two upper levels to the lowest level.In the large atom-field-detuning case,the atomic emission probability decreases as the coherent parameter increases,In the zero atom-field-detuning case,the atomic emission probability has three sets of resonance peaks,The reason for thess results has been explained.

Chinese Physics Letters•Jan 1, 2002•0 citations

Two-mode mazer injected with V-type three-level atoms

Liang Wen-Qing, Zhi‐Ming Zhang, Xie Sheng-wu

The properties of the two-mode mazer operating on V-type three-level atoms are studied. The effect of the one-atom pumping on the two modes of the cavity field in number-state is asymmetric, that is, the atom emits a photon into one mode with some probability and absorbs a photon from the other mode with some other probability. This effect makes the steady-state photon distribution and the steady-state photon statistics asymmetric for the two modes. The diagram of the probability currents for the photon distribution, given by the analysis of the master equation, reveals that there is no detailed balance solution for the master equation. The computations show that the photon statistics of one mode or both modes can be sub-Poissonian, that the two modes can have anticorrelation or correlation, that the photon statistics increases with the increase of thermal photons and that the resonant position and strength of the photon statistics are influenced by the ratio of the two coupling strengths of the two modes. These properties are also discussed physically.

Chinese Physics•Dec 1, 2003•0 citations
The transmission probability of the two-mode mazer injected with V-type three-level atoms is studied and the effects of the atomic coherence on it are examined. It is shown that the atomic coherence can affect the transmission probability. In the plots of the atomic transmission probability versus the dimensionless centre-of-mass momentum, there are resonance peaks and non-resonance platforms. The heights of these resonance peaks and non-resonance platforms can be adjusted by the atomic coherence parameter and by the relative coupling strength of the two transition channels.
The velocity selection of the V-type three-level-atom mazer with atomic coherence is studied. It is shown that the atomic coherence can strongly affect transmission probability, and in turn, the velocity selection of atoms through the micromaser cavity. When the incident atoms are initially prepared in the lower state of the two upper ones (i.e., no injected atomic coherence), velocity selectivity is at a maximum. This shows that atomic coherence does not have a favourable effect on velocity selectivity in this scheme. The effects of other parameters are also studied.
We investigate the effects of the injected atomic coherence on the atomic emission probability of the micromaser injected with ultracold cascade three-level atoms by considering that the atoms are initially in the coherent superposition states of the two upper levels. We show that there is no interference between the transitions from the two upper levels to the lowest level. In the large atom-field-detuning case, the atomic emission probability decreases as the coherent parameter increases. In the zero atom-field-detuning case, the atomic emission probability has three sets of resonance peaks. The reason for these results has been explained.
The effects of the atomic coherence on the photon statistics of the micromaser injected with ultra-cold V-type three-level atoms are studied.In the plot of the atomic emission probability versus the cavity length, there are resonance peaks and non-resonance platforms, which can be adjusted by the atomic coherence parameters.These features of emission probability affect the properties of photon statistics directly. In the plot of the mean number of photons versus the cavity length, there are resonance peaks and non-resonance platforms,too. Given a cavity length, with the change of the atomic coherence parameters, the distribution of photon numbers can move towards the large or small photon numbers, and the mean number of photons increases or decreases accordingly.We also find, with appropriate atomic coherence parameters, that the photon statistics are sub-Poissonian in large region of the cavity length.
We investigate the effects of the injected atomic coherence on the atomic emission probability of the micromaser injected with ultracold cascade three-level atoms by considering that the atoms are initially in the coherent superposition states of the two upper levels,we show that there is no interference between the transitions from the two upper levels to the lowest level.In the large atom-field-detuning case,the atomic emission probability decreases as the coherent parameter increases,In the zero atom-field-detuning case,the atomic emission probability has three sets of resonance peaks,The reason for thess results has been explained.
The properties of the two-mode mazer operating on V-type three-level atoms are studied. The effect of the one-atom pumping on the two modes of the cavity field in number-state is asymmetric, that is, the atom emits a photon into one mode with some probability and absorbs a photon from the other mode with some other probability. This effect makes the steady-state photon distribution and the steady-state photon statistics asymmetric for the two modes. The diagram of the probability currents for the photon distribution, given by the analysis of the master equation, reveals that there is no detailed balance solution for the master equation. The computations show that the photon statistics of one mode or both modes can be sub-Poissonian, that the two modes can have anticorrelation or correlation, that the photon statistics increases with the increase of thermal photons and that the resonant position and strength of the photon statistics are influenced by the ratio of the two coupling strengths of the two modes. These properties are also discussed physically.