Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Phase sensitivity of two nonlinear interferometers with inputting entangled coherent states

Chaoping Wei, Xiao‐Yu Hu, Ya‐Fei Yu, Zhiming Zhang

Published Apr 1, 2016• 16 citations
Publisher

Abstract

We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.

DOI
10.1088/1674-1056/25/4/040601

Related papers

Phase estimation of an SU(1,1) interferometer with superposition of even and odd coherent states

Abdelmajid El Maaroufi, Mouad Ait Maskour, Bouchra Maroufi +1 more

Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.

Physica Scripta•Feb 25, 2026•0 citations

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

High-sensitivity phase estimation with a two-mode squeezed coherent state based on a Mach–Zehnder interferometer

Pengxiang Ruan, Jun Liu, Chenlu Li +3 more

Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.

Chinese Physics B•Jul 28, 2025•0 citations

Optimal phase sensitivity by quantum squeezing based on a Mach–Zehnder interferometer

Jun Liu, Ya Yu, Chengyuan Wang +6 more

Abstract A novel scheme for the enhancement of phase sensitivity based on a Mach–Zehnder interferometer (MZI) and intensity detection is proposed. With the input of bright entangled twin beams from four wave mixing (FWM), the phase sensitivity can beat shot noise limit (SNL) and approach Heisenberg limit. This scheme is special due to that only one of bright entangled twin beams enters into the MZI and the other one is employed for measurement. In addition, by altering the parametric strength of FWM and the implementation of maximum quantum squeezing, the optimal phase sensitivity can reach sub-SNL. Optical intensity depletion of photon detectors and internal intensity depletion of the MZI are also discussed. The scheme displays that by employing external resources, while one input of the MZI is an vacuum beam, the phase sensitivity still can beat SNL.

New Journal of Physics•Dec 18, 2019•22 citations

The phase sensitivity of an SU(1,1) interferometer with coherent and squeezed-vacuum light

Dong Li, Chun-Hua Yuan, Z. Y. Ou +1 more

We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.

arXiv:1305.4769•New Journal of Physics•Jul 17, 2014•119 citations

Phase sensitivity of a quantum Mach-Zehnder interferometer for a coherent state input

Taesoo Kim, Heonoh Kim

The phase sensitivity of a Mach-Zehnder interferometer utilizing quantum entanglement is analyzed for a coherent state input. The results show that the Heisenberg limit in the measurement of the phase shift is obtainable with a coherent input. Moreover, the scheme turns out to be immune to the imperfect detector efficiencies. This suggests another promising route for implementing sub-shot-noise measurement schemes.

Journal of the Optical Society of America B•Mar 12, 2009•5 citations
We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.
Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.
Abstract A novel scheme for the enhancement of phase sensitivity based on a Mach–Zehnder interferometer (MZI) and intensity detection is proposed. With the input of bright entangled twin beams from four wave mixing (FWM), the phase sensitivity can beat shot noise limit (SNL) and approach Heisenberg limit. This scheme is special due to that only one of bright entangled twin beams enters into the MZI and the other one is employed for measurement. In addition, by altering the parametric strength of FWM and the implementation of maximum quantum squeezing, the optimal phase sensitivity can reach sub-SNL. Optical intensity depletion of photon detectors and internal intensity depletion of the MZI are also discussed. The scheme displays that by employing external resources, while one input of the MZI is an vacuum beam, the phase sensitivity still can beat SNL.
We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.