Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Phase sensitivity of a quantum Mach-Zehnder interferometer for a coherent state input

Taesoo Kim, Heonoh Kim

Published Mar 12, 2009• 5 citations
Publisher

Abstract

The phase sensitivity of a Mach-Zehnder interferometer utilizing quantum entanglement is analyzed for a coherent state input. The results show that the Heisenberg limit in the measurement of the phase shift is obtainable with a coherent input. Moreover, the scheme turns out to be immune to the imperfect detector efficiencies. This suggests another promising route for implementing sub-shot-noise measurement schemes.

DOI
10.1364/josab.26.000671

Related papers

The Phase-sensitivity of a Mach-Zehnder Interferometer for Coherent Light

Jong-Tae Shin, Heonoh Kim, Goo-Dong Park +1 more

We have studied the sensitivity of four different phase shift measurement schemes with a Mach-Zehnder interferometer. The input light is considered to be in a coherent state and the detectors are assumed to be ideal with the quantum efficiency of unity. It is shown by direct calculation of the operators corresponding to the measurement schemes that the uncertainty of the phase-shift measurement is limited to the classical one $\frac{1}{\sqrt{m}}$ (m is the average number of the photons in the input state) regardless of the phase-shift measurement schemes.

Journal of the Optical Society of Korea•Mar 1, 1999•10 citations

Sub-shot-noise quantum optical interferometry: a comparison of entangled state performance within a unified measurement scheme

Yang Gao, Hwang Lee

Phase measurement using a lossless Mach–Zehnder interferometer with certain entangled N-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are different for different input states to achieve this limit. We show that it is possible to achieve this limit just by the parity measurement for all the commonly proposed entangled states. Based on the parity measurement scheme, the reductions of the phase sensitivity in the presence of photon loss are examined for the various input states.

arXiv:0803.0155•Journal of Modern Optics•Nov 10, 2008•13 citations

Phase sensitivity of two nonlinear interferometers with inputting entangled coherent states

Chaoping Wei, Xiao‐Yu Hu, Ya‐Fei Yu +1 more

We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.

Chinese Physics B•Apr 1, 2016•16 citations

High-sensitivity phase estimation with a two-mode squeezed coherent state based on a Mach–Zehnder interferometer

Pengxiang Ruan, Jun Liu, Chenlu Li +3 more

Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.

Chinese Physics B•Jul 28, 2025•0 citations

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

Deterministic sub-Heisenberg limit phase sensitivity with the squeezed coherent state via balanced homodyne detection

Chenlu Li, Shaoqiu Ke, Pengxiang Ruan +5 more

Abstract We investigate the phase sensitivities of three schemes with the input of the squeezed coherent states based on the Mach–Zehnder interferometer (MZI). With employing the balanced homodyne detection, the phase sensitivities of these schemes can surpass the shot noise limit (SNL) and reach the sub-Heisenberg limit. By adjusting the combination of the squeezing parameter and the photon number of the coherent state, both the phase sensitivities with using the balanced homodyne detection and the quantum Cramer–Rao bound can be improved. In the regime of low squeezing parameters, the scheme with the two-mode squeezed coherent state outperforms the other two schemes. The phase sensitivity can only reach the sub-SNL when the photon number is much larger. These schemes exhibit strong robustness against internal losses of the MZI and photon detector losses. This work will play an important role in the field of quantum precision measurement.

Physica Scripta•Feb 4, 2025•2 citations
The phase sensitivity of a Mach-Zehnder interferometer utilizing quantum entanglement is analyzed for a coherent state input. The results show that the Heisenberg limit in the measurement of the phase shift is obtainable with a coherent input. Moreover, the scheme turns out to be immune to the imperfect detector efficiencies. This suggests another promising route for implementing sub-shot-noise measurement schemes.
We have studied the sensitivity of four different phase shift measurement schemes with a Mach-Zehnder interferometer. The input light is considered to be in a coherent state and the detectors are assumed to be ideal with the quantum efficiency of unity. It is shown by direct calculation of the operators corresponding to the measurement schemes that the uncertainty of the phase-shift measurement is limited to the classical one 1m\frac{1}{\sqrt{m}}m​1​ (m is the average number of the photons in the input state) regardless of the phase-shift measurement schemes.
Phase measurement using a lossless Mach–Zehnder interferometer with certain entangled N-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are different for different input states to achieve this limit. We show that it is possible to achieve this limit just by the parity measurement for all the commonly proposed entangled states. Based on the parity measurement scheme, the reductions of the phase sensitivity in the presence of photon loss are examined for the various input states.
We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.
Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Abstract We investigate the phase sensitivities of three schemes with the input of the squeezed coherent states based on the Mach–Zehnder interferometer (MZI). With employing the balanced homodyne detection, the phase sensitivities of these schemes can surpass the shot noise limit (SNL) and reach the sub-Heisenberg limit. By adjusting the combination of the squeezing parameter and the photon number of the coherent state, both the phase sensitivities with using the balanced homodyne detection and the quantum Cramer–Rao bound can be improved. In the regime of low squeezing parameters, the scheme with the two-mode squeezed coherent state outperforms the other two schemes. The phase sensitivity can only reach the sub-SNL when the photon number is much larger. These schemes exhibit strong robustness against internal losses of the MZI and photon detector losses. This work will play an important role in the field of quantum precision measurement.