Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Science

Shrinking Atomic Clocks

I. S. Osborne

Published Jan 10, 2013• 0 citations
Publisher

Abstract

Physics Atomic clocks housed in national laboratories around the world provide a precise time signal on which our present high-technology lives depend. Precise synchronization allows for colossal amounts of data to be reliably transferred around networks of optic fibers at ever-increasing rates, as well as providing accurate navigation systems. With increasing demand for mobile devices, there is a requirement for these atom-based time pieces to shrink. Present chip-scale atomic-clock (CSAC) devices based on alkali atoms in a buffer gas are lightweight (<50 g) and consume little power (<150 mW) but tend to show frequency drift over time that requires frequent recalibration. Clocks based on trapped single atoms or ions should be more stable because the atoms are vacuum-packed and do not interact. However, these tend to be relatively large and power-hungry. Jau et al. have developed a miniature atomic clock based on trapped Yb ions that has size and power requirements similar to those of existing CSAC technology but also offers to match the long-term stability expected of the much larger trapping systems. Appl. Phys. Lett. 101 , 253518 (2012).

DOI
10.1126/science.339.6116.120-c

Related papers

The Chip-Scale Atomic Clock - Low-Power Physics Package

Robert Lutwak, Jinyi Deng, William Riley +7 more

We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.

•Dec 1, 2004•64 citations

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•55 citations

Review of chip-scale atomic clocks based on coherent population trapping

Zhong Wang

Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.

Chinese Physics B•Mar 1, 2014•36 citations

Progress on a Miniature Cold-Atom Frequency Standard

David R. Scherer, Robert Lutwak, Mark J. Mescher +8 more

Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.

arXiv:1411.5006•Nov 18, 2014•7 citations

An Advanced-CSAC Testbed for Next-Generation Space Missions: Overview and Recent Results

Zachary Warren, Hunter Kettering, James C. Camparo

More and more, precise timekeeping is becoming a crucial element of space-system operations. Not only are atomic clocks required at mission control ground stations, but they are expected to fly on spacecraft ranging in size from the “large” to CubeSats. This, of course, requires that the size, weight, and power (SWaP) of the clock cannot be sacrificed for frequency stability, and that the frequency stability of the device cannot be sacrificed for SWaP. Traditional space clocks (e.g. Rb clocks, Cs clocks, and hydrogen masers) require microwave cavities, rf-discharge lamps, alkali ovens, hydrogen dissociators, filter vapor-cells, or state-selecting magnets. In contrast, Coherent-Population-Trapping (CPT) clocks can have very low SWaP and have led to the development of the chip-scale atomic-clock (CSAC) – perfect for CubeSat missions. In the standard CPT clock, a narrow atomic resonance is formed by a bichromatic optical field. Unfortunately, in the standard CPT clock design the atomic signal suffers a low signal-to-noise ratio (SNR), due to atoms becoming systemically stuck in “trap” states inaccessible to the laser light. At The Aerospace Corporation’s Physical Sciences Laboratories, we have constructed a CPT atomic clock testbed, with the goal of accelerating CSAC development for next-generation space missions. Specifically, our plan is to investigate atomic physics issues that influence CSAC performance and SWaP, and prioritizing issues not being addressed in academic or industrial laboratories. In this presentation, we will discuss our CPT testbed, and recent work investigating CPT-enhancement strategies for improved clock performance that recover atoms from trap states and improve the SNR. Additionally, we will discuss our studies of the physical processes taking place in these CPT-enhancement strategies, and how they can affect advanced-CSAC functioning and design.

Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting•Feb 23, 2021•0 citations

Advances of chip-scale atomic clock in Peking University

Jianye Zhao, Yaolin Zhang, Haoyuan Lu +3 more

The authors are developing chip-scale atomic clocks (CSACs) based on the85Rb coherent population trap (CPT) transition. As an intermediate milestone, we have developed a miniature atomic clock prototype. In this paper, we report on the design combing the miniature physics part, low-power digital control circuits and low-power microwave system, and the process that enable an atomic clock to be made with an overall size of 20 cm3volume, power consumption about 400 mWatts, and an Allen Deviation at 100 s of 2.9E-11.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•1 citation
Physics
Atomic clocks housed in national laboratories around the world provide a precise time signal on which our present high-technology lives depend. Precise synchronization allows for colossal amounts of data to be reliably transferred around networks of optic fibers at ever-increasing rates, as well as providing accurate navigation systems. With increasing demand for mobile devices, there is a requirement for these atom-based time pieces to shrink. Present chip-scale atomic-clock (CSAC) devices based on alkali atoms in a buffer gas are lightweight (<50 g) and consume little power (<150 mW) but tend to show frequency drift over time that requires frequent recalibration. Clocks based on trapped single atoms or ions should be more stable because the atoms are vacuum-packed and do not interact. However, these tend to be relatively large and power-hungry. Jau et al. have developed a miniature atomic clock based on trapped Yb ions that has size and power requirements similar to those of existing CSAC technology but also offers to match the long-term stability expected of the much larger trapping systems.
Appl. Phys. Lett. 101 , 253518 (2012).
We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.
Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.
More and more, precise timekeeping is becoming a crucial element of space-system operations. Not only are atomic clocks required at mission control ground stations, but they are expected to fly on spacecraft ranging in size from the “large” to CubeSats. This, of course, requires that the size, weight, and power (SWaP) of the clock cannot be sacrificed for frequency stability, and that the frequency stability of the device cannot be sacrificed for SWaP. Traditional space clocks (e.g. Rb clocks, Cs clocks, and hydrogen masers) require microwave cavities, rf-discharge lamps, alkali ovens, hydrogen dissociators, filter vapor-cells, or state-selecting magnets. In contrast, Coherent-Population-Trapping (CPT) clocks can have very low SWaP and have led to the development of the chip-scale atomic-clock (CSAC) – perfect for CubeSat missions. In the standard CPT clock, a narrow atomic resonance is formed by a bichromatic optical field. Unfortunately, in the standard CPT clock design the atomic signal suffers a low signal-to-noise ratio (SNR), due to atoms becoming systemically stuck in “trap” states inaccessible to the laser light. At The Aerospace Corporation’s Physical Sciences Laboratories, we have constructed a CPT atomic clock testbed, with the goal of accelerating CSAC development for next-generation space missions. Specifically, our plan is to investigate atomic physics issues that influence CSAC performance and SWaP, and prioritizing issues not being addressed in academic or industrial laboratories. In this presentation, we will discuss our CPT testbed, and recent work investigating CPT-enhancement strategies for improved clock performance that recover atoms from trap states and improve the SNR. Additionally, we will discuss our studies of the physical processes taking place in these CPT-enhancement strategies, and how they can affect advanced-CSAC functioning and design.
The authors are developing chip-scale atomic clocks (CSACs) based on the85Rb coherent population trap (CPT) transition. As an intermediate milestone, we have developed a miniature atomic clock prototype. In this paper, we report on the design combing the miniature physics part, low-power digital control circuits and low-power microwave system, and the process that enable an atomic clock to be made with an overall size of 20 cm3volume, power consumption about 400 mWatts, and an Allen Deviation at 100 s of 2.9E-11.