Foundations of Quantum Mechanics in the Light of New Technology

SINGLE SHOT MEASUREMENT OF A SILICON SINGLE ELECTRON TRANSISTOR

T. Ferrus, D. G. HASKO, Q. Morrissey, S. R. Burge, E. J. FREEMAN, Marcus J. French, A. LAM, L. Creswell, R. J. COLLIER, D. A. WILLIAMS, G. Andrew D. Briggs

Published Jun 1, 2009• 1 citation
Publisher

Abstract

We describe measurements on a silicon single electron transistor (SET) carried out using a custom cryogenic CMOS measurement circuit (LTCMOS) in close proximity to the device. Quantum mechanical states in the SET were mapped by continuous microwave spectroscopy. The real time evolution of a particularly long lived quantum mechanical state was observed in a single shot measurement, made possible by the much faster measurement rate (50kHz bandwidth). This technique is intended to be applied to the measurement of coherent states in a charge qubit device made of a silicon double dot.

DOI
10.1142/9789814282130_0070

Related papers

Single shot measurement in silicon single electron transistors

T. Ferrus, D. A. Williams, D. G. Hasko +7 more

A major problem of usual current measurement setup is the severe limitations on the bandwidth due to room temperature electronics. This restricts the practical measurement rate to below 10 Hz and makes impossible to observe the evolution of a quantum state in real time. Here we describe a measurement on a silicon single electron transistor (SET) carried out using a custom CMOS measurement circuit in close proximity to the device under test. Both the device and the CMOS circuit are maintained in the same cryogenic environment. Quantum mechanical states in the single electron transistor (SET) were mapped by continuous microwave spectroscopy. The real time evolution of a particularly long lived quantum mechanical state was observed in a single shot measurement, made possible by the much faster measurement rate. This technique will shortly be applied to the measurement of coherent states in a charge qubit device made of a silicon double dot.

IEEE Silicon Nanoelectronics Workshop•Jun 1, 2008•0 citations

Single shot measurement of a silicon single electron transistor

D. G. Hasko, T. Ferrus, Q. Morrissey +8 more

We have fabricated a custom cryogenic complementary metal-oxide-semiconductor integrated circuit that has a higher measurement bandwidth compared to conventional room temperature electronics. This allowed implementing single shot operations and observe the real-time evolution of the current of a phosphorus-doped silicon single electron transistor that was irradiated with a microwave pulse. Relaxation times up to 90μs are observed, suggesting the presence of well isolated electron excitations within the device. It is expected that these are associated with long decoherence time and the device may be suitable for quantum information processing.

arXiv:0811.0736•Applied Physics Letters•Nov 10, 2008•10 citations

Cryogenic instrumentation for fast current measurement in a silicon single electron transistor

T. Ferrus, D. G. Hasko, Q. R. Morrissey +8 more

We present a realization of high bandwidth instrumentation at cryogenic temperatures and for dilution refrigerator operation that possesses advantages over methods using radio frequency single electron transistor or transimpedance amplifiers. The ability for the low temperature electronics to carry out faster measurements than with room temperature electronics is investigated by the use of a phosphorous-doped single electron transistor. A single shot technique is successfully implemented and used to observe the real-time decay of a quantum state. A discussion on various measurement strategies is presented and the consequences on electron heating and noise are analyzed.

arXiv:0904.3193•Journal of Applied Physics•Aug 1, 2009•8 citations

Towards Single Shot Measurements of a Cooper Pair Box Qubit Using an RF Single Electron Transistor

Carlos Alberto Sánchez

I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.

•Dec 5, 2005•0 citations

Sub-Nanoampere One-Shot Single Electron Transistor Readout Electrometry Below 10 Kelvin

Kushal Das, Torsten Lehmann, Andrew S. Dzurak

The Single Electron Transistor holds the potential to be a suitable readout device for future solid-state quantum computers. The low temperature measurement results of a 0.5 μm Silicon-On-Sapphire CMOS circuit designed to interface with a Single Electron Transistor are presented. Careful design of the experimental set-up is critical for conducting the circuit test and performance measurements at cryogenic temperatures. The circuit operates at 4 K and achieves single-shot readout with a resolution in the order of one nanoampere. A detection delay as low as 1.5 μs is recorded while dissipating only 20-30 μW power.

IEEE Transactions on Circuits and Systems I Regular Papers•Sep 18, 2014•18 citations

Single-shot readout with the radio-frequency single-electron transistor in the presence of charge noise

Tilo M. Buehler, D. J. Reilly, R.P. Starrett +4 more

The radio-frequency single-electron transistor (rf-SET) possesses key requirements necessary for reading out a solid state quantum computer. This work explores the use of the rf-SET as a single-shot readout device in the presence of 1∕f and telegraph charge noise. For a typical spectrum of 1∕f noise we find that high fidelity, single-shot measurements are possible for signals Δq>0.01e. For the case of telegraph noise, we present a cross-correlation measurement technique that uses two rf-SETs to suppress the effect of random switching events on readout. We demonstrate this technique by monitoring the charge state of a metal double dot system on microsecond time scales. Such a scheme will be advantageous in achieving high readout fidelity in a solid-state quantum computer.

arXiv:cond-mat/0304384•Applied Physics Letters•Mar 31, 2005•46 citations
We describe measurements on a silicon single electron transistor (SET) carried out using a custom cryogenic CMOS measurement circuit (LTCMOS) in close proximity to the device. Quantum mechanical states in the SET were mapped by continuous microwave spectroscopy. The real time evolution of a particularly long lived quantum mechanical state was observed in a single shot measurement, made possible by the much faster measurement rate (50kHz bandwidth). This technique is intended to be applied to the measurement of coherent states in a charge qubit device made of a silicon double dot.
A major problem of usual current measurement setup is the severe limitations on the bandwidth due to room temperature electronics. This restricts the practical measurement rate to below 10 Hz and makes impossible to observe the evolution of a quantum state in real time. Here we describe a measurement on a silicon single electron transistor (SET) carried out using a custom CMOS measurement circuit in close proximity to the device under test. Both the device and the CMOS circuit are maintained in the same cryogenic environment. Quantum mechanical states in the single electron transistor (SET) were mapped by continuous microwave spectroscopy. The real time evolution of a particularly long lived quantum mechanical state was observed in a single shot measurement, made possible by the much faster measurement rate. This technique will shortly be applied to the measurement of coherent states in a charge qubit device made of a silicon double dot.
We have fabricated a custom cryogenic complementary metal-oxide-semiconductor integrated circuit that has a higher measurement bandwidth compared to conventional room temperature electronics. This allowed implementing single shot operations and observe the real-time evolution of the current of a phosphorus-doped silicon single electron transistor that was irradiated with a microwave pulse. Relaxation times up to 90μs are observed, suggesting the presence of well isolated electron excitations within the device. It is expected that these are associated with long decoherence time and the device may be suitable for quantum information processing.
We present a realization of high bandwidth instrumentation at cryogenic temperatures and for dilution refrigerator operation that possesses advantages over methods using radio frequency single electron transistor or transimpedance amplifiers. The ability for the low temperature electronics to carry out faster measurements than with room temperature electronics is investigated by the use of a phosphorous-doped single electron transistor. A single shot technique is successfully implemented and used to observe the real-time decay of a quantum state. A discussion on various measurement strategies is presented and the consequences on electron heating and noise are analyzed.
I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.
The Single Electron Transistor holds the potential to be a suitable readout device for future solid-state quantum computers. The low temperature measurement results of a 0.5 μm Silicon-On-Sapphire CMOS circuit designed to interface with a Single Electron Transistor are presented. Careful design of the experimental set-up is critical for conducting the circuit test and performance measurements at cryogenic temperatures. The circuit operates at 4 K and achieves single-shot readout with a resolution in the order of one nanoampere. A detection delay as low as 1.5 μs is recorded while dissipating only 20-30 μW power.
The radio-frequency single-electron transistor (rf-SET) possesses key requirements necessary for reading out a solid state quantum computer. This work explores the use of the rf-SET as a single-shot readout device in the presence of 1∕f and telegraph charge noise. For a typical spectrum of 1∕f noise we find that high fidelity, single-shot measurements are possible for signals Δq>0.01e. For the case of telegraph noise, we present a cross-correlation measurement technique that uses two rf-SETs to suppress the effect of random switching events on readout. We demonstrate this technique by monitoring the charge state of a metal double dot system on microsecond time scales. Such a scheme will be advantageous in achieving high readout fidelity in a solid-state quantum computer.