Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Optics

Magnetic-field-compensation optical vector magnetometer

A. Papoyan, Svetlana Shmavonyan, Alen Khanbekyan, K. Khanbekyan, C. Marinelli, E. Mariotti

Published Feb 1, 2016• 35 citations
Publisher

Abstract

A concept for an optical magnetometer used for the measurement of magnitude and direction of a magnetic field (B-field) in two orthogonal directions is developed based on double scanning of a B-field to compensate the measured field to zero value, which is monitored by a resonant magneto-optical process in an unshielded atomic vapor cell. Implementation of the technique using the nonlinear Hanle effect on the D2 line of rubidium demonstrates viability and efficiency of the proposed concept. The ways to enhance characteristics of the suggested technique and optimize its performance, as well as the possible extension to three-axis magnetometry, are discussed.

DOI
10.1364/ao.55.000892

Related papers

High-speed optical three-axis vector magnetometry based on nonlinear Hanle effect in rubidium vapor

H. H. Azizbekyan, Svetlana Shmavonyan, Aleksandr Khanbekyan +2 more

The magnetic-field-compensation optical vector magnetometer based on the nonlinear Hanle effect in alkali metal vapor allowing two-axis measurement operation has been further elaborated for three-axis performance, along with significant reduction of measurement time. The upgrade was achieved by implementing a two-beam resonant excitation configuration and a fast maximum searching algorithm. Results of the proof-of-concept experiments, demonstrating 1 μTB-field resolution, are presented. The applied interest and capability of the proposed technique is analyzed.

Optical Engineering•Jul 25, 2017•15 citations

All-Optical Vector Atomic Magnetometer

Brian Patton, E. Zhivun, D. C. Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and $0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}$ in the field direction; elimination of technical noise would improve these sensitivities to $12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

arXiv:1403.7545•Physical Review Letters•Jul 1, 2014•207 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•12 citations

Demonstration of a field-deployable vector magnetometer using synchronous coherent population trapping and feedback compensation mechanism

Renu Tripathi, G. S. Pati, Mauricio Pulido

We have developed a field-deployable vector magnetometer using a small rubidium vapor cell, which is capable of measuring the magnitude and direction of the earth's magnetic field with high accuracy and sensitivity. The magnetometer measures Larmor precession of rubidium atoms using the phenomenon, called synchronous coherent population trapping (SCPT). This gives the advantage of producing a high contrast and narrow linewidth resonance needed for measuring the magnetic field with high accuracy and sensitivity. The magnetometer exhibits sub-nT/√Hz sensitivities in measuring the field components along the three directions.

SPIE Quantum Information Science, Sensing, and Computation•Jun 7, 2024•0 citations

Magnetic Field Compensation for An Optically Pumped Magnetometer Without Iteration

Yaqiong Niu, Chaofeng Ye

The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 29, 2023•1 citation

Magnetometry with Microwave-Assisted Optical Pumping in Warm Rb Vapor and Microfabricated Rb Vapor Cells

Lu, Ying-Ying

Quantum optical sensing is a maturing field that offers the capability to achieve extraor- dinary sensitivity. Atomic magnetometers, for example, now have the capability to detect brain signals and to precisely measure Earth’s gravity field. In optical atomic magnetome- ters, the electronic spins of the atoms in vapor form are aligned in the same direction by “pumping” the ensemble using laser light at a select frequency. Any magnetic field alters the spin states, which changes the optical properties of the vapor, such as the transmission of the laser light, providing a way to measure magnetic fields. After reviewing the theory of atomic structure and atom-light interactions relevant to the research presented here, I describe in the first part of this thesis a vector magnetometry method using microwave-assisted optical pumping, in which a microwave field resonant to the ground state hyperfine splitting of 87Rb pumps an ensemble of warm rubidium vapor, in addition to a strong optical pump beam, and a weaker optical probe beam. I present theoretical details as well as preliminary data demonstrating magnetic field measurements of a DC magnetic field. The measurements were taken when the DC field was aligned at various angles relative to the microwave magnetic field alignment. I compare theoretical and experimental differences in the measurements. With new methods for quantum devices comes the need for portability. In the second part of this thesis, we demonstrate the fabrication of millimeter-sized rubidium vapor cells using silicon micro-machining techniques. This method is relatively inexpensive compared to glass-blowing methods and allows rapid, large-scale production. I describe our process flow and demonstrate the presence of rubidium atoms inside our vapor cells. To conclude, suggestions for improvement are discussed.

•Jan 1, 2021•0 citations
A concept for an optical magnetometer used for the measurement of magnitude and direction of a magnetic field (B-field) in two orthogonal directions is developed based on double scanning of a B-field to compensate the measured field to zero value, which is monitored by a resonant magneto-optical process in an unshielded atomic vapor cell. Implementation of the technique using the nonlinear Hanle effect on the D2 line of rubidium demonstrates viability and efficiency of the proposed concept. The ways to enhance characteristics of the suggested technique and optimize its performance, as well as the possible extension to three-axis magnetometry, are discussed.
The magnetic-field-compensation optical vector magnetometer based on the nonlinear Hanle effect in alkali metal vapor allowing two-axis measurement operation has been further elaborated for three-axis performance, along with significant reduction of measurement time. The upgrade was achieved by implementing a two-beam resonant excitation configuration and a fast maximum searching algorithm. Results of the proof-of-concept experiments, demonstrating 1 μTB-field resolution, are presented. The applied interest and capability of the proposed technique is analyzed.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and 0.5  mrad/Hz0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}0.5  mrad/Hz​ in the field direction; elimination of technical noise would improve these sensitivities to 12  fT/Hz12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}12  fT/Hz​ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
We have developed a field-deployable vector magnetometer using a small rubidium vapor cell, which is capable of measuring the magnitude and direction of the earth's magnetic field with high accuracy and sensitivity. The magnetometer measures Larmor precession of rubidium atoms using the phenomenon, called synchronous coherent population trapping (SCPT). This gives the advantage of producing a high contrast and narrow linewidth resonance needed for measuring the magnetic field with high accuracy and sensitivity. The magnetometer exhibits sub-nT/√Hz sensitivities in measuring the field components along the three directions.
The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.
Quantum optical sensing is a maturing field that offers the capability to achieve extraor- dinary sensitivity. Atomic magnetometers, for example, now have the capability to detect brain signals and to precisely measure Earth’s gravity field. In optical atomic magnetome- ters, the electronic spins of the atoms in vapor form are aligned in the same direction by “pumping” the ensemble using laser light at a select frequency. Any magnetic field alters the spin states, which changes the optical properties of the vapor, such as the transmission of the laser light, providing a way to measure magnetic fields. After reviewing the theory of atomic structure and atom-light interactions relevant to the research presented here, I describe in the first part of this thesis a vector magnetometry method using microwave-assisted optical pumping, in which a microwave field resonant to the ground state hyperfine splitting of 87Rb pumps an ensemble of warm rubidium vapor, in addition to a strong optical pump beam, and a weaker optical probe beam. I present theoretical details as well as preliminary data demonstrating magnetic field measurements of a DC magnetic field. The measurements were taken when the DC field was aligned at various angles relative to the microwave magnetic field alignment. I compare theoretical and experimental differences in the measurements. With new methods for quantum devices comes the need for portability. In the second part of this thesis, we demonstrate the fabrication of millimeter-sized rubidium vapor cells using silicon micro-machining techniques. This method is relatively inexpensive compared to glass-blowing methods and allows rapid, large-scale production. I describe our process flow and demonstrate the presence of rubidium atoms inside our vapor cells. To conclude, suggestions for improvement are discussed.