Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical Engineering

High-speed optical three-axis vector magnetometry based on nonlinear Hanle effect in rubidium vapor

H. H. Azizbekyan, Svetlana Shmavonyan, Aleksandr Khanbekyan, Marina Movsisyan, A. Papoyan

Published Jul 25, 2017• 15 citations
Publisher

Abstract

The magnetic-field-compensation optical vector magnetometer based on the nonlinear Hanle effect in alkali metal vapor allowing two-axis measurement operation has been further elaborated for three-axis performance, along with significant reduction of measurement time. The upgrade was achieved by implementing a two-beam resonant excitation configuration and a fast maximum searching algorithm. Results of the proof-of-concept experiments, demonstrating 1 μTB-field resolution, are presented. The applied interest and capability of the proposed technique is analyzed.

DOI
10.1117/1.oe.56.7.074104

Related papers

Magnetic-field-compensation optical vector magnetometer

A. Papoyan, Svetlana Shmavonyan, Alen Khanbekyan +3 more

A concept for an optical magnetometer used for the measurement of magnitude and direction of a magnetic field (B-field) in two orthogonal directions is developed based on double scanning of a B-field to compensate the measured field to zero value, which is monitored by a resonant magneto-optical process in an unshielded atomic vapor cell. Implementation of the technique using the nonlinear Hanle effect on the D2 line of rubidium demonstrates viability and efficiency of the proposed concept. The ways to enhance characteristics of the suggested technique and optimize its performance, as well as the possible extension to three-axis magnetometry, are discussed.

Applied Optics•Feb 1, 2016•35 citations

An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer

Shengran Su, Zhen-Yuan Xu, Xiang He +6 more

Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.

Sensors•Mar 15, 2023•16 citations

Three-axis isotropic-sensitivity He4 magnetometer with alignment-based longitudinal parametric resonance

Bowen Wang, Xiang Peng, Wei Xiao +1 more

For measurements in near-zero magnetic fields, vector atomic magnetometers are promising alternatives to scalar versions, but generally suffer from inconsistent performance over three axes. We present a single-beam vector magnetometer with three-axis isotropic sensitivity based on $^{4}\mathrm{He}$ atomic alignment. Longitudinal parametric resonance with atoms pumped by linearly polarized light is proposed for the $z$-axis measurement, while the Hanle effect in transverse geometry is used for $x$- and $y$-axis measurements. The evolution of atomic alignment multipole components and expressions of the three-axis magnetic responses are analyzed in detail. We describe the experimental operation of the proposed magnetometer with a magnetic-field noise floor of $150\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}$ for the three axes, which is attractive for biomagnetism requiring vector characterization and source reconstruction.

Physical Review A•Dec 12, 2022•6 citations

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 6, 2021•129 citations

All-Optical Vector Atomic Magnetometer

Brian Patton, E. Zhivun, D. C. Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and $0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}$ in the field direction; elimination of technical noise would improve these sensitivities to $12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

arXiv:1403.7545•Physical Review Letters•Jul 1, 2014•207 citations

Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

Shushan Gao, Xiaoyu Li, Jianwei Sheng +5 more

The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz${}^{\text {1/2}}$for the$x$- and$y$-axes, and a longitudinal sensitivity of 70 fT/Hz${}^{\text {1/2}}$for the$z$-axis in a$4\times 4\times 4$mm${}^{\text {3 87}}$Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations
The magnetic-field-compensation optical vector magnetometer based on the nonlinear Hanle effect in alkali metal vapor allowing two-axis measurement operation has been further elaborated for three-axis performance, along with significant reduction of measurement time. The upgrade was achieved by implementing a two-beam resonant excitation configuration and a fast maximum searching algorithm. Results of the proof-of-concept experiments, demonstrating 1 μTB-field resolution, are presented. The applied interest and capability of the proposed technique is analyzed.
A concept for an optical magnetometer used for the measurement of magnitude and direction of a magnetic field (B-field) in two orthogonal directions is developed based on double scanning of a B-field to compensate the measured field to zero value, which is monitored by a resonant magneto-optical process in an unshielded atomic vapor cell. Implementation of the technique using the nonlinear Hanle effect on the D2 line of rubidium demonstrates viability and efficiency of the proposed concept. The ways to enhance characteristics of the suggested technique and optimize its performance, as well as the possible extension to three-axis magnetometry, are discussed.
Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.
For measurements in near-zero magnetic fields, vector atomic magnetometers are promising alternatives to scalar versions, but generally suffer from inconsistent performance over three axes. We present a single-beam vector magnetometer with three-axis isotropic sensitivity based on 4He^{4}\mathrm{He}4He atomic alignment. Longitudinal parametric resonance with atoms pumped by linearly polarized light is proposed for the zzz-axis measurement, while the Hanle effect in transverse geometry is used for xxx- and yyy-axis measurements. The evolution of atomic alignment multipole components and expressions of the three-axis magnetic responses are analyzed in detail. We describe the experimental operation of the proposed magnetometer with a magnetic-field noise floor of 150fT/Hz1/2150\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}150fT/Hz1/2 for the three axes, which is attractive for biomagnetism requiring vector characterization and source reconstruction.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and 0.5  mrad/Hz0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}0.5  mrad/Hz​ in the field direction; elimination of technical noise would improve these sensitivities to 12  fT/Hz12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}12  fT/Hz​ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz1/2{}^{\text {1/2}}1/2for thexxx- andyyy-axes, and a longitudinal sensitivity of 70 fT/Hz1/2{}^{\text {1/2}}1/2for thezzz-axis in a4×4×44\times 4\times 44×4×4mm3 87{}^{\text {3 87}}3 87Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.