Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1403.7545 · Physical Review Letters

All-Optical Vector Atomic Magnetometer

Brian Patton, E. Zhivun, D. C. Hovde, Dmitry Budker

Published Jul 1, 2014• 186 citations
arXivHTMLPDF

Abstract

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and $0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}$ in the field direction; elimination of technical noise would improve these sensitivities to $12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

DOI
10.1103/physrevlett.113.013001

Related papers

All-optical vector atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

Bulletin of the American Physical Society•Jun 5, 2014•21 citations

All Optical Scalar Atomic Magnetometer Capable of Vector Measurement

Rui Zhang, Rahul R. Mhaskar, Ken A. Smith +2 more

Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 milliseconds, better than 0.02 degree sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0 to 180 degrees. Better than 1 degree error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with an additional orthogonally oriented sensor.

•Nov 17, 2020•0 citations

Vector measurements using all optical scalar atomic magnetometers

Rui Zhang, Rahul Mhaskar, Ken Smith +2 more

Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.

arXiv:2011.08943•Journal of Applied Physics•Jan 28, 2021•17 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations

All-Optical Vector Cesium Magnetometer

Weimin Sun, Qiang Huang, Zongjun Huang +2 more

Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80 fT/Hz 1/2 and an orientation sensitivity of 0.1°/Hz 1/2 . In the device, four main factors are measured experimentally, which are the Larmor precession frequency of a polarized magnetic moment that depends on the modulus of the measured magnetic field only, two phase shifts and amplitude ratio of the precession projection in the two probe directions relative to the magnetic field orientation. This kind of magnetometer with high sensitivity in the range of the spatial angle is suitable for solving the inverse problem and geomagnetic navigation.

Chinese Physics Letters•May 1, 2017•12 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•11 citations
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of \ensuremath∼65  fT/Hz\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}\ensuremath∼65  fT/Hz​ in measurement of the field magnitude and 0.5  mrad/Hz0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}0.5  mrad/Hz​ in the field direction; elimination of technical noise would improve these sensitivities to 12  fT/Hz12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}12  fT/Hz​ and 10  \ensuremathμrad/Hz10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}10  \ensuremathμrad/Hz​, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 milliseconds, better than 0.02 degree sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0 to 180 degrees. Better than 1 degree error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with an additional orthogonally oriented sensor.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80 fT/Hz 1/2 and an orientation sensitivity of 0.1°/Hz 1/2 . In the device, four main factors are measured experimentally, which are the Larmor precession frequency of a polarized magnetic moment that depends on the modulus of the measured magnetic field only, two phase shifts and amplitude ratio of the precession projection in the two probe directions relative to the magnetic field orientation. This kind of magnetometer with high sensitivity in the range of the spatial angle is suitable for solving the inverse problem and geomagnetic navigation.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.