Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Journal of Selected Topics in Quantum Electronics

Parametric Amplification of Images: From Time Gating to Noiseless Amplification

Éric Lantz, F. Devaux

Published Jan 1, 2008• 35 citations
Publisher

Abstract

Image parametric amplification and its applications are reviewed in this paper. Phase matching conditions allow the resolution to be determined and spatial frequency filtering to be performed. The phase conjugate idler image can be used to cancel aberrations. Then, time gating properties are applied to ultrafast imaging, imaging through diffusing media, and lifetime fluorescence imaging. Degenerate schemes permit polychromatic amplification as well as phase-sensitive amplification, which is proved to be noiseless with respect to spatial fluctuations at the quantum level. Finally, it is shown that the spatial fluctuations of the signal and the idler are subshot noise correlated.

DOI
10.1109/jstqe.2008.918650

Related papers

Parametric amplification of images

Éric Lantz, F. Devaux

Image parametric amplification and its applications are summarized. The link between resolution and phase matching is presented. Then applications to ultrafast imaging and imaging through diffusing media are given. Last, degenerate schemes are proved to permit polychromatic amplification as well as phase-sensitive amplification.

Quantum and Semiclassical Optics Journal of the European Optical Society Part B•Apr 1, 1997•23 citations

Phase-sensitive parametric image amplification: application to noiseless image amplification

Fabrice Deveaux, Éric Lantz

We report semi-classical numeric simulations of the quantum spatial fluctuations in parametric amplification of images limited by the shot noise. Noiseless amplification of images is demonstrated by the use of a degenerate type 2 phase sensitive amplifier.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2001•0 citations

Noiseless image amplification by a phase-sensitive parametric amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.

Conference on Lasers and Electro-Optics•Jan 1, 1998•1 citation

Quantum fluctuation in traveling-wave amplification of optical images

I. V. Sokolov, Mikhail I. Kolobov, Luigi A. Lugiato

We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently by Kolobov and Lugiato [Phys. Rev. A 52, 4930 (1995)] for a cavity-based geometry, such a scheme can amplify images, without deteriorating their sign-to-noise ratio, thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We investigate in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. The spatial resolution power, which guarantees noiseless amplification is estimated. We demonstrate how the optimum phase matching of a phase-sensitive wavefront of the image can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the effect of improvement of the signal-to-noise ratio in the case of observation of both the input and the amplified image, with an ideal photodetector of small area (i.e., much less than the coherence area of the amplifier). This improvement is due to the fact that the signal-to-noise ratio in the input is deteriorated by the observation with the photodetector of small area.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 25, 1999•1 citation

Measurement of quantum-noise correlations in parametric image amplification

M. Marable, Sang Kyung Choi, Prem Kumar

We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.

Optics Express•Feb 2, 1998•21 citations

Quantum Image Generation by c.w. Optical Parametric Amplification

L. Lopez, Nicolas Treps, Claude Fabre +1 more

In this paper, experimental evidence of cw amplification of images in the quantum regime, using a phase sensitive optical parametric amplification operating inside transverse degenerate cavities. Injecting various images (mismatched Gaussian modes and double slits of different orientations) at the input of the device, showed that the output image was amplitude squeezed by 30% in the regime of deamplification of a type II frequency-degenerate OPO operating below threshold in a semi-confocal cavity, when the polarization of the input image is at 45deg from the crystal axes. The authors showed also that, in the regime of amplification, the two polarization components along the signal and idler axes had quantum correlated intensity fluctuations (intensity difference fluctuations measured at 30% below the standard quantum noise level).

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations
Image parametric amplification and its applications are reviewed in this paper. Phase matching conditions allow the resolution to be determined and spatial frequency filtering to be performed. The phase conjugate idler image can be used to cancel aberrations. Then, time gating properties are applied to ultrafast imaging, imaging through diffusing media, and lifetime fluorescence imaging. Degenerate schemes permit polychromatic amplification as well as phase-sensitive amplification, which is proved to be noiseless with respect to spatial fluctuations at the quantum level. Finally, it is shown that the spatial fluctuations of the signal and the idler are subshot noise correlated.
Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.
We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently by Kolobov and Lugiato [Phys. Rev. A 52, 4930 (1995)] for a cavity-based geometry, such a scheme can amplify images, without deteriorating their sign-to-noise ratio, thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We investigate in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. The spatial resolution power, which guarantees noiseless amplification is estimated. We demonstrate how the optimum phase matching of a phase-sensitive wavefront of the image can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the effect of improvement of the signal-to-noise ratio in the case of observation of both the input and the amplified image, with an ideal photodetector of small area (i.e., much less than the coherence area of the amplifier). This improvement is due to the fact that the signal-to-noise ratio in the input is deteriorated by the observation with the photodetector of small area.
We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.
In this paper, experimental evidence of cw amplification of images in the quantum regime, using a phase sensitive optical parametric amplification operating inside transverse degenerate cavities. Injecting various images (mismatched Gaussian modes and double slits of different orientations) at the input of the device, showed that the output image was amplitude squeezed by 30% in the regime of deamplification of a type II frequency-degenerate OPO operating below threshold in a semi-confocal cavity, when the polarization of the input image is at 45deg from the crystal axes. The authors showed also that, in the regime of amplification, the two polarization components along the signal and idler axes had quantum correlated intensity fluctuations (intensity difference fluctuations measured at 30% below the standard quantum noise level).