Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Phase-sensitive parametric image amplification: application to noiseless image amplification

Fabrice Deveaux, Éric Lantz

Published Mar 2, 2001• 0 citations
Publisher

Abstract

We report semi-classical numeric simulations of the quantum spatial fluctuations in parametric amplification of images limited by the shot noise. Noiseless amplification of images is demonstrated by the use of a degenerate type 2 phase sensitive amplifier.
DOI
10.1117/12.417752

Related papers

Noiseless image amplification by a phase-sensitive parametric amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.

Conference on Lasers and Electro-Optics•Jan 1, 1998•1 citation

Noiseless Optical Amplification of Images

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

We used a spatially broadband optical parametric amplifier for image amplification. In the phase-sensitive configuration of the amplifier, we observed noiseless amplification of input images. For a gain of $\ensuremath{\simeq}2.5$, we measured noise-figure values of ( $0.2\ifmmode\pm\else\textpm\fi{}0.6$) and ( $0.4\ifmmode\pm\else\textpm\fi{}0.5$) dB, respectively, for two amplifiers of different lengths. These experimental values agree with theory (for an ideal noiseless amplifier the noise figure is 0 dB) and are almost 2 dB lower than the quantum limit of an ideal phase-insensitive amplifier.

Physical Review Letters•Sep 6, 1999•135 citations

Observation of Noiseless Image Amplification by an Optical Parametric Amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

A spatially-broadband optical parametric amplifier is used for image amplification. In the phase-sensitive configuration, we observe a noise figure of −0.1± 0.3dB for a gain of 2.4, which is 2dB lower than the quantum limit for an ideal phase-insensitive amplifier. Image pre-amplification before loss is shown to improve the detected signal-to-noise ratio.

Kluwer Academic Publishers eBooks•Dec 19, 2005•1 citation

Spatially Noiseless Optical Amplification of Images

A. Mosset, F. Devaux, Éric Lantz

We present the first experimental demonstration of noiseless amplification of images, where noise refers to spatial quantum fluctuations on the pixels of single shot images. Phase-sensitive and phase-insensitive schemes are compared and the noise figures are in good agreement with theory, inasmuch this theory includes the quantum efficiency of the whole system and the pixel size.

Physical Review Letters•Jun 9, 2005•76 citations

Parametric Amplification of Images: From Time Gating to Noiseless Amplification

Éric Lantz, F. Devaux

Image parametric amplification and its applications are reviewed in this paper. Phase matching conditions allow the resolution to be determined and spatial frequency filtering to be performed. The phase conjugate idler image can be used to cancel aberrations. Then, time gating properties are applied to ultrafast imaging, imaging through diffusing media, and lifetime fluorescence imaging. Degenerate schemes permit polychromatic amplification as well as phase-sensitive amplification, which is proved to be noiseless with respect to spatial fluctuations at the quantum level. Finally, it is shown that the spatial fluctuations of the signal and the idler are subshot noise correlated.

IEEE Journal of Selected Topics in Quantum Electronics•Jan 1, 2008•35 citations

Quantum Image Generation by c.w. Optical Parametric Amplification

L. Lopez, Nicolas Treps, Claude Fabre +1 more

In this paper, experimental evidence of cw amplification of images in the quantum regime, using a phase sensitive optical parametric amplification operating inside transverse degenerate cavities. Injecting various images (mismatched Gaussian modes and double slits of different orientations) at the input of the device, showed that the output image was amplitude squeezed by 30% in the regime of deamplification of a type II frequency-degenerate OPO operating below threshold in a semi-confocal cavity, when the polarization of the input image is at 45deg from the crystal axes. The authors showed also that, in the regime of amplification, the two polarization components along the signal and idler axes had quantum correlated intensity fluctuations (intensity difference fluctuations measured at 30% below the standard quantum noise level).

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations
Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.
We used a spatially broadband optical parametric amplifier for image amplification. In the phase-sensitive configuration of the amplifier, we observed noiseless amplification of input images. For a gain of $\ensuremath{\simeq}2.5$, we measured noise-figure values of ( $0.2\ifmmode\pm\else\textpm\fi{}0.6$) and ( $0.4\ifmmode\pm\else\textpm\fi{}0.5$) dB, respectively, for two amplifiers of different lengths. These experimental values agree with theory (for an ideal noiseless amplifier the noise figure is 0 dB) and are almost 2 dB lower than the quantum limit of an ideal phase-insensitive amplifier.
Image parametric amplification and its applications are reviewed in this paper. Phase matching conditions allow the resolution to be determined and spatial frequency filtering to be performed. The phase conjugate idler image can be used to cancel aberrations. Then, time gating properties are applied to ultrafast imaging, imaging through diffusing media, and lifetime fluorescence imaging. Degenerate schemes permit polychromatic amplification as well as phase-sensitive amplification, which is proved to be noiseless with respect to spatial fluctuations at the quantum level. Finally, it is shown that the spatial fluctuations of the signal and the idler are subshot noise correlated.
In this paper, experimental evidence of cw amplification of images in the quantum regime, using a phase sensitive optical parametric amplification operating inside transverse degenerate cavities. Injecting various images (mismatched Gaussian modes and double slits of different orientations) at the input of the device, showed that the output image was amplitude squeezed by 30% in the regime of deamplification of a type II frequency-degenerate OPO operating below threshold in a semi-confocal cavity, when the polarization of the input image is at 45deg from the crystal axes. The authors showed also that, in the regime of amplification, the two polarization components along the signal and idler axes had quantum correlated intensity fluctuations (intensity difference fluctuations measured at 30% below the standard quantum noise level).