Kluwer Academic Publishers eBooks

Observation of Noiseless Image Amplification by an Optical Parametric Amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

Published Dec 19, 2005• 1 citation
Publisher

Abstract

A spatially-broadband optical parametric amplifier is used for image amplification. In the phase-sensitive configuration, we observe a noise figure of −0.1± 0.3dB for a gain of 2.4, which is 2dB lower than the quantum limit for an ideal phase-insensitive amplifier. Image pre-amplification before loss is shown to improve the detected signal-to-noise ratio.

DOI
10.1007/0-306-47097-7_64

Related papers

Noiseless Optical Amplification of Images

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

We used a spatially broadband optical parametric amplifier for image amplification. In the phase-sensitive configuration of the amplifier, we observed noiseless amplification of input images. For a gain of $\ensuremath{\simeq}2.5$, we measured noise-figure values of ( $0.2\ifmmode\pm\else\textpm\fi{}0.6$) and ( $0.4\ifmmode\pm\else\textpm\fi{}0.5$) dB, respectively, for two amplifiers of different lengths. These experimental values agree with theory (for an ideal noiseless amplifier the noise figure is 0 dB) and are almost 2 dB lower than the quantum limit of an ideal phase-insensitive amplifier.

Physical Review Letters•Sep 6, 1999•135 citations

Noiseless image amplification by a phase-sensitive parametric amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.

Conference on Lasers and Electro-Optics•Jan 1, 1998•1 citation

Quantum fluctuation in traveling-wave amplification of optical images

I. V. Sokolov, Mikhail I. Kolobov, Luigi A. Lugiato

We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently by Kolobov and Lugiato [Phys. Rev. A 52, 4930 (1995)] for a cavity-based geometry, such a scheme can amplify images, without deteriorating their sign-to-noise ratio, thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We investigate in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. The spatial resolution power, which guarantees noiseless amplification is estimated. We demonstrate how the optimum phase matching of a phase-sensitive wavefront of the image can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the effect of improvement of the signal-to-noise ratio in the case of observation of both the input and the amplified image, with an ideal photodetector of small area (i.e., much less than the coherence area of the amplifier). This improvement is due to the fact that the signal-to-noise ratio in the input is deteriorated by the observation with the photodetector of small area.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 25, 1999•1 citation

Controlling the signal-to-noise ratio in optical parametric image amplification

Kaige Wang, Guojian Yang, A. Gatti +1 more

We analyse a scheme for phase-sensitive amplification of an optical image without using Fourier-transforming lenses, as carried out in a recent experiment. Our analysis shows that the scheme works well with a broadband amplifier, which ensures that the output image is a faithful copy of the object. In addition, when the area of the pixel detector is close to the minimum imaging resolution, both a large output signal-to-noise ratio and noiseless amplification can be realized.

Journal of Optics B Quantum and Semiclassical Optics•Aug 1, 2003•12 citations

Measurement of quantum-noise correlations in parametric image amplification

M. Marable, Sang Kyung Choi, Prem Kumar

We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.

Optics Express•Feb 2, 1998•21 citations

Quantum fluctuations in traveling-wave amplification of optical images

I. V. Sokolov, Mikhail I. Kolobov, Luigi Lugiato

We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently for a cavity-based geometry, such a scheme can amplify images without deteriorating their signal-to-noise ratio thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We study in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. We investigate physical features of noiseless amplification, which take place for both traveling-wave and ring-cavity configurations. We demonstrate how the optimum phase matching of a phase-sensitive wave front of an image (by means of a thin lens or a small displacement of the crystal) can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the possibility of using detectors with the area much smaller than the area of the input image elements. We compare our results with those obtained for the ring-cavity configuration.

Physical Review A•Sep 1, 1999•35 citations
A spatially-broadband optical parametric amplifier is used for image amplification. In the phase-sensitive configuration, we observe a noise figure of −0.1± 0.3dB for a gain of 2.4, which is 2dB lower than the quantum limit for an ideal phase-insensitive amplifier. Image pre-amplification before loss is shown to improve the detected signal-to-noise ratio.
We used a spatially broadband optical parametric amplifier for image amplification. In the phase-sensitive configuration of the amplifier, we observed noiseless amplification of input images. For a gain of $\ensuremath{\simeq}2.5$, we measured noise-figure values of ( $0.2\ifmmode\pm\else\textpm\fi{}0.6$) and ( $0.4\ifmmode\pm\else\textpm\fi{}0.5$) dB, respectively, for two amplifiers of different lengths. These experimental values agree with theory (for an ideal noiseless amplifier the noise figure is 0 dB) and are almost 2 dB lower than the quantum limit of an ideal phase-insensitive amplifier.
Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.
We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently by Kolobov and Lugiato [Phys. Rev. A 52, 4930 (1995)] for a cavity-based geometry, such a scheme can amplify images, without deteriorating their sign-to-noise ratio, thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We investigate in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. The spatial resolution power, which guarantees noiseless amplification is estimated. We demonstrate how the optimum phase matching of a phase-sensitive wavefront of the image can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the effect of improvement of the signal-to-noise ratio in the case of observation of both the input and the amplified image, with an ideal photodetector of small area (i.e., much less than the coherence area of the amplifier). This improvement is due to the fact that the signal-to-noise ratio in the input is deteriorated by the observation with the photodetector of small area.
We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.
We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently for a cavity-based geometry, such a scheme can amplify images without deteriorating their signal-to-noise ratio thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We study in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. We investigate physical features of noiseless amplification, which take place for both traveling-wave and ring-cavity configurations. We demonstrate how the optimum phase matching of a phase-sensitive wave front of an image (by means of a thin lens or a small displacement of the crystal) can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the possibility of using detectors with the area much smaller than the area of the input image elements. We compare our results with those obtained for the ring-cavity configuration.