An Optical Lattice Clock with Fermionic and Bosonic Sr Atoms

Xavier Baillard, Mathilde Fouché, Rodolphe Le Targat, Philip G. Westergaard, Arnaud Lecallier, Fréderic Chapelet, S. Bize, P. Rosenbusch, Michel Abgrall, Phillipe Laurent, Yann Le Coq, Daniele Rovera, Andr  Clairon, P. Lemonde, B. Lipphardt, Gesine Grosche, H. Schnatz

Published Aug 1, 2007• 0 citations
Publisher

Abstract

We report recent experiments performed with our Sr optical lattice clock. With the fermionic isotope87Sr, the clock accuracy approaches 10-15using spin-polarized atoms. We also report the first accuracy evaluation of an optical lattice clock with bosonic atoms, here88Sr.
DOI
10.1109/cleopr.2007.4391551

Related papers

Frequency comparison between optical lattice clocks

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka +1 more

Two "optical lattice clocks", which based on spin-polarized fermionic 87Sr trapped in a one-dimensional optical lattice and on bosonic 88Sr in a three-dimensional lattice, were operated simultaneously. From a beat note between the two optical clocks, stability as well as accuracy of "optical lattice clocks" were evaluated. We report the progress of the measurements.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 9, 2007•0 citations

Three-dimensional optical lattice clock with bosonic Sr 88 atoms

Tomoya Akatsuka, Masao Takamoto, Hidetoshi Katori

We present detailed analyses of our recent experiment on the three-dimensional (3D) optical lattice clock with bosonic $^{88}\mathrm{Sr}$ atoms in which the collisional frequency shift was suppressed by applying a single-occupancy lattice. Frequency shifts in magnetically induced spectroscopy on the ${}^{1}{S}_{0}--{}^{3}{P}_{0}$ clock transition ($\ensuremath{\lambda}=698$ nm) of $^{88}\mathrm{Sr}$ were experimentally investigated by referencing a one-dimensional (1D) lattice clock based on spin-polarized $^{87}\mathrm{Sr}$ atoms. We discuss that the clock stability is limited by the current laser stability as well as the experimental sequence of the clock operation, which may be improved to ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})=2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}$ by optimizing the cycle time of the clock operation.

Physical Review A•Feb 4, 2010•79 citations

Optical lattice clocks with non-interacting bosons and fermions

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka +1 more

We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes; one-dimensional lattice loaded with spin-polarized fermions and three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic87Sr and bosonic88Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address our ongoing experimental challenges for optical lattice clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2008•2 citations

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY

Andrew D. Ludlow, Sebastian Blatt, M. BOYD +12 more

We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16

Laser Spectroscopy•Apr 1, 2008•0 citations

Optical lattice clocks and frequency comparison

Hidetoshi Katori, T. Takano, Masao Takamoto

We consider designs of optical lattice clocks in view of the quantum statistics, relevant atomic spins, and atom-lattice interactions. The first two issues lead to two optimal constructions for the clock: a one-dimensional (1D) optical lattice loaded with spin-polarized fermions and a 3D optical lattice loaded with bosons. By taking atomic multipolar interactions with the lattice fields into account, an "atomic motion insensitive" wavelength is proposed to provide a precise definition of the "magic wavelength." We then present a frequency comparison of these two optical lattice clocks: spin-polarized fermionic 87 Sr and bosonic 88 Sr prepared in 1D and 3D optical lattices, respectively. Synchronous interrogations of these two optical lattice clocks by the same probe laser allowed canceling out its frequency noise as a common mode noise to achieve a relative stability of 3 × 10 −17 for an averaging time of τ = 350 s. The scheme, therefore, provides us with a powerful means to investigate intrinsic uncertainty of the clocks regardless of the probe laser stability. We discuss prospects of the synchronous operation of the clocks on the measurement of the geoid height difference and on the search of constancy of fundamental constants.

Journal of Physics Conference Series•Jan 10, 2011•2 citations

Accuracy evaluation of an optical lattice clock with bosonic atoms

Xavier Baillard, Mathilde Fouché, Rodolphe Le Targat +6 more

We report what we believe to be the first accuracy evaluation of an optical lattice clock based on the S01-->P03 transition of an alkaline earth boson, namely, Sr88 atoms. This transition has been enabled by using a static coupling magnetic field. The clock frequency is determined to be 429228066418009(32)Hz. The isotopic shift between Sr87 and Sr88 is 62188135Hz with fractional uncertainty 5x10(-7). We discuss the necessary conditions to reach a clock accuracy of 10(-17) or less by using this scheme.

arXiv:physics/0703148•Optics Letters•Jun 20, 2007•100 citations
We present detailed analyses of our recent experiment on the three-dimensional (3D) optical lattice clock with bosonic 88Sr^{88}\mathrm{Sr}88Sr atoms in which the collisional frequency shift was suppressed by applying a single-occupancy lattice. Frequency shifts in magnetically induced spectroscopy on the 1S0−−3P0{}^{1}{S}_{0}--{}^{3}{P}_{0}1S0​−−3P0​ clock transition ($\ensuremath{\lambda}=698$ nm) of 88Sr^{88}\mathrm{Sr}88Sr were experimentally investigated by referencing a one-dimensional (1D) lattice clock based on spin-polarized 87Sr^{87}\mathrm{Sr}87Sr atoms. We discuss that the clock stability is limited by the current laser stability as well as the experimental sequence of the clock operation, which may be improved to ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})=2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}$ by optimizing the cycle time of the clock operation.
We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes; one-dimensional lattice loaded with spin-polarized fermions and three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic87Sr and bosonic88Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address our ongoing experimental challenges for optical lattice clocks.
We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16
We consider designs of optical lattice clocks in view of the quantum statistics, relevant atomic spins, and atom-lattice interactions. The first two issues lead to two optimal constructions for the clock: a one-dimensional (1D) optical lattice loaded with spin-polarized fermions and a 3D optical lattice loaded with bosons. By taking atomic multipolar interactions with the lattice fields into account, an "atomic motion insensitive" wavelength is proposed to provide a precise definition of the "magic wavelength." We then present a frequency comparison of these two optical lattice clocks: spin-polarized fermionic 87 Sr and bosonic 88 Sr prepared in 1D and 3D optical lattices, respectively. Synchronous interrogations of these two optical lattice clocks by the same probe laser allowed canceling out its frequency noise as a common mode noise to achieve a relative stability of 3 × 10 −17 for an averaging time of τ = 350 s. The scheme, therefore, provides us with a powerful means to investigate intrinsic uncertainty of the clocks regardless of the probe laser stability. We discuss prospects of the synchronous operation of the clocks on the measurement of the geoid height difference and on the search of constancy of fundamental constants.
We report what we believe to be the first accuracy evaluation of an optical lattice clock based on the S01-->P03 transition of an alkaline earth boson, namely, Sr88 atoms. This transition has been enabled by using a static coupling magnetic field. The clock frequency is determined to be 429228066418009(32)Hz. The isotopic shift between Sr87 and Sr88 is 62188135Hz with fractional uncertainty 5x10(-7). We discuss the necessary conditions to reach a clock accuracy of 10(-17) or less by using this scheme.