Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)

Gain banwidth for superconducting hot electron bolometers at terahertz waveband

Yi Jiang, Biaobing Jin, Lin Kang, Weiwei Xu, Junlong Chen, Peiheng Wu

Published Sep 1, 2012• 0 citations
Publisher

Abstract

Intermediate frequency (IF) gain bandwidth (GBW) of terahertz (THz) heterodyne detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) has been studied in details. Two different methods, resulting in same IF GBW value of about 3.5 GHz are reported here.
DOI
10.1109/irmmw-thz.2012.6380456

Related papers

Improved IF gain bandwidth for terahertz mixers based on superconducting hot electron bolometers

H. Zhang, Shoulu Jiang, Xiaoqing Jia +5 more

Intermediate frequency (IF) gain bandwidth (GBW) of terahertz (THz) mixers based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) has been improved. The IF GBW has been measured by 2 different methods and same values up to 7 GHz have been obtained.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2014•0 citations

Superconducting detectors for terahertz imaging

Shoulu Jiang, Xiaoqing Jia, Biaobing Jin +4 more

Superconducting niobium nitride (NbN) hot electron bolometer (HEB) detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna's inner terminals have been fabricated and characterized. For its performance as a heterodyne mixer, the system DSB noise temperature of about 500 K and the intermediate frequency (IF) gain bandwidth (GBW) of about 4 GHz have been obtained at 4.2 K and 0.65 THz. For its performance as a direct detector, a microwave-driven scheme has been tried.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 1, 2015•2 citations

Terahertz Direct Detectors Based on Superconducting Hot Electron Bolometers with Microwave Biasing

Shoulu Jiang, Xianfeng Li, Runfeng Su +7 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) biasing are studied. The MW is used to bias the HEB to the optimum point and to readout the impedance changes caused by the incident THz signals. Compared with the thermal biasing method, this method would be more promising in large scale array with simple readout. The used NbN HEB has an excellent performance as heterodyne detector with the double sideband noise temperature (TN) of 403 K working at 4.2 K and 0.65 THz. As a result, the noise equivalent power of 1.5 pW/Hz1/2 and the response time of 64 ps are obtained for the direct detectors based on the NbN HEBs and working at 4.2 K and 0.65 THz.

Chinese Physics Letters•Aug 1, 2017•7 citations

NbN hot electron bolometric mixers for terahertz receivers

M. Kroug, Serguei Cherednichenko, H. Merkel +5 more

Sensitivity and gain bandwidth measurements of phonon-cooled NbN superconducting hot-electron bolometer mixers are presented. The best receiver noise temperatures are: 700 K at 1.6 THz and 1100 K at 2.5 THz. Parylene as an antireflection coating on silicon has been investigated and used in the optics of the receiver. The dependence of the mixer gain bandwidth (GBW) on the bias voltage has been measured. Starting from low bias voltages, close to operating conditions yielding the lowest noise temperature, the GBW increases towards higher bias voltages, up to three times the initial value. The highest measured GBW is 9 GHz within the same bias range the noise temperature increases by a factor of two.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•75 citations

Terahertz (THz) direct detectors based on superconducting HEBs with thermal, THz and microwave biasing methods (Conference Presentation)

Jian Chen

Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.

Next-Generation Spectroscopic Technologies•May 14, 2019•0 citations

Heterodyne Mixing and Direct Detection Performance of a Superconducting NbN Hot-Electron Bolometer

W. Zhang, W. Miao, Kangmin Zhou +4 more

The heterodyne mixing and direct detection performance of a superconducting NbN hot-electron bolometer (HEB) integrated with a log-spiral antenna have been thoroughly characterized. The corrected receiver noise temperature and IF gain bandwidth are approximately 800 K at 0.5 THz, 750 K at 0.85 THz and 3 GHz at its optimum bias point. In addition, both the receiver noise temperature and IF gain bandwidth were found insensitive to the bath temperature, while the bias point was fixed, in good agreement with those simulated with the hot-spot model taking account of the HEB's current-dependent resistive transition. Furthermore, the HEB's frequency response was measured by a Fourier transform spectrometer at different bias points and bath temperatures. The estimated noise equivalent power (NEP) was close to 10-13W/Hz0.5around the HEB's transition temperature.

IEEE Transactions on Applied Superconductivity•Jan 13, 2011•14 citations
Superconducting niobium nitride (NbN) hot electron bolometer (HEB) detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna's inner terminals have been fabricated and characterized. For its performance as a heterodyne mixer, the system DSB noise temperature of about 500 K and the intermediate frequency (IF) gain bandwidth (GBW) of about 4 GHz have been obtained at 4.2 K and 0.65 THz. For its performance as a direct detector, a microwave-driven scheme has been tried.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) biasing are studied. The MW is used to bias the HEB to the optimum point and to readout the impedance changes caused by the incident THz signals. Compared with the thermal biasing method, this method would be more promising in large scale array with simple readout. The used NbN HEB has an excellent performance as heterodyne detector with the double sideband noise temperature (TN) of 403 K working at 4.2 K and 0.65 THz. As a result, the noise equivalent power of 1.5 pW/Hz1/2 and the response time of 64 ps are obtained for the direct detectors based on the NbN HEBs and working at 4.2 K and 0.65 THz.
Sensitivity and gain bandwidth measurements of phonon-cooled NbN superconducting hot-electron bolometer mixers are presented. The best receiver noise temperatures are: 700 K at 1.6 THz and 1100 K at 2.5 THz. Parylene as an antireflection coating on silicon has been investigated and used in the optics of the receiver. The dependence of the mixer gain bandwidth (GBW) on the bias voltage has been measured. Starting from low bias voltages, close to operating conditions yielding the lowest noise temperature, the GBW increases towards higher bias voltages, up to three times the initial value. The highest measured GBW is 9 GHz within the same bias range the noise temperature increases by a factor of two.
Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.
The heterodyne mixing and direct detection performance of a superconducting NbN hot-electron bolometer (HEB) integrated with a log-spiral antenna have been thoroughly characterized. The corrected receiver noise temperature and IF gain bandwidth are approximately 800 K at 0.5 THz, 750 K at 0.85 THz and 3 GHz at its optimum bias point. In addition, both the receiver noise temperature and IF gain bandwidth were found insensitive to the bath temperature, while the bias point was fixed, in good agreement with those simulated with the hot-spot model taking account of the HEB's current-dependent resistive transition. Furthermore, the HEB's frequency response was measured by a Fourier transform spectrometer at different bias points and bath temperatures. The estimated noise equivalent power (NEP) was close to 10-13W/Hz0.5around the HEB's transition temperature.