NbN hot electron bolometric mixers for terahertz receivers

M. Kroug, Serguei Cherednichenko, H. Merkel, E. Kollberg, B. Voronov, G. N. Gol'tsman, Heinz‐Wilhelm Hübers, Heiko Richter

Published Mar 1, 2001• 75 citations
Publisher

Abstract

Sensitivity and gain bandwidth measurements of phonon-cooled NbN superconducting hot-electron bolometer mixers are presented. The best receiver noise temperatures are: 700 K at 1.6 THz and 1100 K at 2.5 THz. Parylene as an antireflection coating on silicon has been investigated and used in the optics of the receiver. The dependence of the mixer gain bandwidth (GBW) on the bias voltage has been measured. Starting from low bias voltages, close to operating conditions yielding the lowest noise temperature, the GBW increases towards higher bias voltages, up to three times the initial value. The highest measured GBW is 9 GHz within the same bias range the noise temperature increases by a factor of two.

DOI
10.1109/77.919508

Related papers

Low Noise Receivers at 1.6 THz and 2.5 THz Based on Niobium Nitride Hot Electron Bolometer Mixers

Jianhui Chen, Min Liang, Lin Kang +7 more

Low noise receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured in the terahertz (THz) frequency range for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. Double sideband (DSB) receiver noise temperatures of 920 K at 1.6 THz and 1630 K at 2.5 THz have been obtained at 4.2 K without corrections. Effects of Parylene C AR coating on the lens have been studied; with such a coating a lowest DSB receiver noise temperature of 1135 K at 2.5 THz has been obtained at 4.2 K.

IEEE Transactions on Applied Superconductivity•May 27, 2009•16 citations

Prop erties of Terahertz Superconducting Hot Electron Bolometer Mixers

J. Chen, Biao Jin, Weizong Xu +3 more

A quasi-optical superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixer has been fabricated and measured in the terahertz (THz) frequency range of 0.5~2.52 THz. A receiver noise temperature of 2000 K at 2.52 THz has been obtained for the mixer without corrections. Also, the effect of a Parylene C anti-reflection (AR) coating on the silicon (Si) lens has been studied.

•Jan 1, 2008•3 citations

NbN hot electron bolometric mixers-a new technology for low-noise THz receivers

Eyal Gerecht, Charles F. Musante, Yan Zhuang +4 more

New advances in hot electron bolometer (HEB) mixers have recently resulted in record-low receiver noise temperatures at terahertz frequencies. We have developed quasi-optically coupled NbN HEB mixers and measured noise temperatures up to 2.24 THz, as described in this paper. We project the anticipated future performance of such receivers to have even lower noise temperature and local-oscillator power requirement as well as wider gain and noise bandwidths. We introduce a proposal for integrated focal plane arrays of HEB mixers that will further increase the detection speed of terahertz systems.

IEEE Transactions on Microwave Theory and Techniques•Jan 1, 1999•39 citations

Low noise and wide bandwidth of NbN hot-electron bolometer mixers

Ivan V. Tretyakov, Рябчун Сергей Александрович, Matvey I. Finkel +5 more

We report a record double sideband noise temperature of 600 K (5hν/kB) offered by a NbN hot-electron bolometer receiver at 2.5 THz. Allowing for standing wave effects, this value was found to be constant in the intermediate frequency range 1–7 GHz, which indicates that the mixer has an unprecedentedly large noise bandwidth in excess of 7 GHz. The insight into this is provided by gain bandwidth measurements performed at the superconducting transition. They show that the dependence of the bandwidth on the mixer length follows the model for an HEB mixer with diffusion and phonon cooling of the hot electrons.

Applied Physics Letters•Jan 17, 2011•77 citations

NbN phonon-cooled hot-electron bolometer mixer for terahertz heterodyne receivers

Gregory N Gol'tsman, Yu. B. Vachtomin, Sergey V. Antipov +8 more

We present the results of our studies of NbN phonon-cooled HEB mixers at terahertz frequencies. The mixers were fabricated from NbN film deposited on a high-resistivity Si substrate with an MgO buffer layer. The mixer element was integrated with a log-periodic spiral antenna. The noise temperature measurements were performed at 2.5 THz and at 3.8 THz local oscillator frequencies for the 3 x 0.2 μm2 active area devices. The best uncorrected receiver noise temperatures found for these frequencies are 1300 K and 3100 K, respectively. A water vapour discharge laser was used as the LO source. The largest gain bandwidth of 5.2 GHz was achieved for a mixer based on 2 nm thick NbN film deposited on MgO layer over Si substrate. The gain bandwidth of the mixer based on 3.5 nm NbN film deposited on Si with MgO is 4.2 GHz and the noise bandwidth for the same device amounts to 5 GHz. We also present the results of our research into decrease of the direct detection contribution to the measured Y-factor and a possible error of noise temperature calculation. The use of a square nickel cell mesh as an IR-filter enabled us to avoid the effect of direct detection and measure apparent value of the noise temperature which was 16% less than that obtained using conventional black polyethylene IR-filter.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 25, 2005•11 citations

NbN hot electron bolometric mixers-a new technology for low noise THz receivers

Eyal Gerecht, Charles F. Musante, Yan Zhuang +8 more

New advances in Hot Electron Bolometer (HEB) mixers have resulted in record low receiver noise temperatures at THz frequencies recently. We have developed quasi-optically coupled NbN HEB mixers and measured noise temperatures up to 1.56 THz, as described in this paper. We project the anticipated future performance of such receivers to have even lower noise temperature and LO power requirement as well as wider gain and noise bandwidths. We introduce a proposal for integrated focal plane arrays of HEB mixers which will further increase the detection speed of THz systems.

IEEE MTT-S International Microwave Symposium digest•Jan 20, 2003•23 citations
Sensitivity and gain bandwidth measurements of phonon-cooled NbN superconducting hot-electron bolometer mixers are presented. The best receiver noise temperatures are: 700 K at 1.6 THz and 1100 K at 2.5 THz. Parylene as an antireflection coating on silicon has been investigated and used in the optics of the receiver. The dependence of the mixer gain bandwidth (GBW) on the bias voltage has been measured. Starting from low bias voltages, close to operating conditions yielding the lowest noise temperature, the GBW increases towards higher bias voltages, up to three times the initial value. The highest measured GBW is 9 GHz within the same bias range the noise temperature increases by a factor of two.
Low noise receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured in the terahertz (THz) frequency range for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. Double sideband (DSB) receiver noise temperatures of 920 K at 1.6 THz and 1630 K at 2.5 THz have been obtained at 4.2 K without corrections. Effects of Parylene C AR coating on the lens have been studied; with such a coating a lowest DSB receiver noise temperature of 1135 K at 2.5 THz has been obtained at 4.2 K.
New advances in hot electron bolometer (HEB) mixers have recently resulted in record-low receiver noise temperatures at terahertz frequencies. We have developed quasi-optically coupled NbN HEB mixers and measured noise temperatures up to 2.24 THz, as described in this paper. We project the anticipated future performance of such receivers to have even lower noise temperature and local-oscillator power requirement as well as wider gain and noise bandwidths. We introduce a proposal for integrated focal plane arrays of HEB mixers that will further increase the detection speed of terahertz systems.
We report a record double sideband noise temperature of 600 K (5hν/kB) offered by a NbN hot-electron bolometer receiver at 2.5 THz. Allowing for standing wave effects, this value was found to be constant in the intermediate frequency range 1–7 GHz, which indicates that the mixer has an unprecedentedly large noise bandwidth in excess of 7 GHz. The insight into this is provided by gain bandwidth measurements performed at the superconducting transition. They show that the dependence of the bandwidth on the mixer length follows the model for an HEB mixer with diffusion and phonon cooling of the hot electrons.
We present the results of our studies of NbN phonon-cooled HEB mixers at terahertz frequencies. The mixers were fabricated from NbN film deposited on a high-resistivity Si substrate with an MgO buffer layer. The mixer element was integrated with a log-periodic spiral antenna. The noise temperature measurements were performed at 2.5 THz and at 3.8 THz local oscillator frequencies for the 3 x 0.2 μm2 active area devices. The best uncorrected receiver noise temperatures found for these frequencies are 1300 K and 3100 K, respectively. A water vapour discharge laser was used as the LO source. The largest gain bandwidth of 5.2 GHz was achieved for a mixer based on 2 nm thick NbN film deposited on MgO layer over Si substrate. The gain bandwidth of the mixer based on 3.5 nm NbN film deposited on Si with MgO is 4.2 GHz and the noise bandwidth for the same device amounts to 5 GHz. We also present the results of our research into decrease of the direct detection contribution to the measured Y-factor and a possible error of noise temperature calculation. The use of a square nickel cell mesh as an IR-filter enabled us to avoid the effect of direct detection and measure apparent value of the noise temperature which was 16% less than that obtained using conventional black polyethylene IR-filter.
New advances in Hot Electron Bolometer (HEB) mixers have resulted in record low receiver noise temperatures at THz frequencies recently. We have developed quasi-optically coupled NbN HEB mixers and measured noise temperatures up to 1.56 THz, as described in this paper. We project the anticipated future performance of such receivers to have even lower noise temperature and LO power requirement as well as wider gain and noise bandwidths. We introduce a proposal for integrated focal plane arrays of HEB mixers which will further increase the detection speed of THz systems.