Chinese Physics Letters

Terahertz Direct Detectors Based on Superconducting Hot Electron Bolometers with Microwave Biasing

Shoulu Jiang, Xianfeng Li, Runfeng Su, Xiaoqing Jia, Xuecou Tu, Lin Kang, Biaobing Jin, Weiwei Xu, Jian Chen, Peiheng Wu

Published Aug 1, 2017• 7 citations
Publisher

Abstract

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) biasing are studied. The MW is used to bias the HEB to the optimum point and to readout the impedance changes caused by the incident THz signals. Compared with the thermal biasing method, this method would be more promising in large scale array with simple readout. The used NbN HEB has an excellent performance as heterodyne detector with the double sideband noise temperature (TN) of 403 K working at 4.2 K and 0.65 THz. As a result, the noise equivalent power of 1.5 pW/Hz1/2 and the response time of 64 ps are obtained for the direct detectors based on the NbN HEBs and working at 4.2 K and 0.65 THz.

DOI
10.1088/0256-307x/34/9/090701

Related papers

Terahertz direct detectors based on superconducting hot electron bolometers with microwave injection

Shoulu Jiang, X. F. Li, Runfeng Su +5 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) injection have been studied. Compared to the thermal biasing method, the injected MW is used here to bias the HEB to the optimum point. MW can be expected to be used as the easy read out for the detecting array. The used NbN HEB has an excellent performance as heterodyne detector with the noise temperature of 403 K working at 4.2 K and 0.65 THz. As the result, the noise equivalent power (NEP) of 1.4 pW/Hz1/2and the response time of 64 ps have been obtained for the direct detectors with MW injection.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 1, 2017•2 citations

Appropriate microwave frequency selection for biasing superconducting hot electron bolometers as terahertz direct detectors

Shoulu Jiang, X F Li, Xiaoqing Jia +5 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) and biased by a simple microwave (MW) source have been studied. The frequency and power of the MW are selected by measuring the MW responses of the current–voltage ( I–V ) curves and resistance–temperature ( R–T ) curves of the NbN HEBs. The non-uniform absorption theory is used to explain the current jumps in the I–V curves and the resistance jumps in the R–T curves. Compared to the thermal biasing, the MW biasing method can improve the sensitivity, make the readout system much easier and consumes less liquid helium, which is important for long lasting experiments. The noise equivalent power (NEP) of 1.6 pW Hz −1/2 and the response time of 86 ps are obtained for the detectors working at 4.2 K and 0.65 THz.

Superconductor Science and Technology•Feb 22, 2017•28 citations

Terahertz (THz) Direct Detectors based on Superconducting HEBs with Thermal, Microwave and THz Biasing

Runfeng Su, Y. D. Zhang, Xuecou Tu +6 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with thermal, microwave (MW) and THz biasing have been studied at 0.65 THz and 4.2 K in detail. The current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the MW and THz biasing have about one order higher current responsivity than that of the thermal one. With the MW biasing, an NEP at the order of pW/√Hz is obtained by choosing the MW frequency and power appropriately.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2018•0 citations

Terahertz (THz) direct detectors based on superconducting HEBs with thermal, THz and microwave biasing methods (Conference Presentation)

Jian Chen

Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.

Next-Generation Spectroscopic Technologies•May 14, 2019•0 citations

Terahertz Direct Detectors Based on Superconducting Hot Electron Bolometers With Different Biasing Methods

Runfeng Su, Yi Di Zhang, Xuecou Tu +6 more

Terahertz (THz) direct detectors based on superconducting niobium nitride hot electron bolometers with thermal, microwave and THz biasing methods have been studied at a frequency of 0.65 THz and at an operating temperature of 4.2 K. A low noise amplifier at room temperature is used to read out the current change of the detectors modulated by the chopping frequency at 732 Hz. The noise spectral density, current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the microwave and THz biasing methods have about one order higher current responsivity than that of the thermal one. With the microwave biasing, an optical NEP at the order of pW/√Hz which shows no deterioration is obtained by choosing the microwave frequency and power appropriately.

IEEE Transactions on Applied Superconductivity•Apr 22, 2019•12 citations

Performance improvements of a terahertz direct detector for imaging arrays

Runfeng Su, H Wang, Lili Shi +12 more

Abstract We studied and improved the performance of a terahertz (THz) direct detector based on the superconducting NbN hot electron bolometer (HEB) integrated with microwave readout for imaging arrays and other applications. A 6 nm thick NbN microbridge at the feed point of a twin-slot antenna is embedded into a high- Q quarter-wavelength coplanar waveguide (CPW) resonator made from a 350 nm thick NbN film which is weakly coupled to a CPW feedline. THz direct detection was performed at a signal frequency of 0.66 THz at a bath temperature of 4.2 K. When operating at a low input microwave power level, the device acting as a microwave kinetic inductance detector with a kinetic inductance fraction of 0.45 changes the surface impedance of the resonator in response to incident THz radiation. The estimated optical noise equivalent power ( NEP ) is ∼0.23 pW · Hz −0.5 which shows about one order of magnitude improvement compared to that of the traditional voltage-biased NbN HEBs. The improved performance of the THz direct detectors with lower NEP and easy readout makes them promising in imaging with a large number of the array pixels.

Superconductor Science and Technology•Jun 11, 2021•2 citations
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) biasing are studied. The MW is used to bias the HEB to the optimum point and to readout the impedance changes caused by the incident THz signals. Compared with the thermal biasing method, this method would be more promising in large scale array with simple readout. The used NbN HEB has an excellent performance as heterodyne detector with the double sideband noise temperature (TN) of 403 K working at 4.2 K and 0.65 THz. As a result, the noise equivalent power of 1.5 pW/Hz1/2 and the response time of 64 ps are obtained for the direct detectors based on the NbN HEBs and working at 4.2 K and 0.65 THz.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) injection have been studied. Compared to the thermal biasing method, the injected MW is used here to bias the HEB to the optimum point. MW can be expected to be used as the easy read out for the detecting array. The used NbN HEB has an excellent performance as heterodyne detector with the noise temperature of 403 K working at 4.2 K and 0.65 THz. As the result, the noise equivalent power (NEP) of 1.4 pW/Hz1/2and the response time of 64 ps have been obtained for the direct detectors with MW injection.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) and biased by a simple microwave (MW) source have been studied. The frequency and power of the MW are selected by measuring the MW responses of the current–voltage ( I–V ) curves and resistance–temperature ( R–T ) curves of the NbN HEBs. The non-uniform absorption theory is used to explain the current jumps in the I–V curves and the resistance jumps in the R–T curves. Compared to the thermal biasing, the MW biasing method can improve the sensitivity, make the readout system much easier and consumes less liquid helium, which is important for long lasting experiments. The noise equivalent power (NEP) of 1.6 pW Hz −1/2 and the response time of 86 ps are obtained for the detectors working at 4.2 K and 0.65 THz.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with thermal, microwave (MW) and THz biasing have been studied at 0.65 THz and 4.2 K in detail. The current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the MW and THz biasing have about one order higher current responsivity than that of the thermal one. With the MW biasing, an NEP at the order of pW/√Hz is obtained by choosing the MW frequency and power appropriately.
Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.
Terahertz (THz) direct detectors based on superconducting niobium nitride hot electron bolometers with thermal, microwave and THz biasing methods have been studied at a frequency of 0.65 THz and at an operating temperature of 4.2 K. A low noise amplifier at room temperature is used to read out the current change of the detectors modulated by the chopping frequency at 732 Hz. The noise spectral density, current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the microwave and THz biasing methods have about one order higher current responsivity than that of the thermal one. With the microwave biasing, an optical NEP at the order of pW/√Hz which shows no deterioration is obtained by choosing the microwave frequency and power appropriately.
Abstract We studied and improved the performance of a terahertz (THz) direct detector based on the superconducting NbN hot electron bolometer (HEB) integrated with microwave readout for imaging arrays and other applications. A 6 nm thick NbN microbridge at the feed point of a twin-slot antenna is embedded into a high- Q quarter-wavelength coplanar waveguide (CPW) resonator made from a 350 nm thick NbN film which is weakly coupled to a CPW feedline. THz direct detection was performed at a signal frequency of 0.66 THz at a bath temperature of 4.2 K. When operating at a low input microwave power level, the device acting as a microwave kinetic inductance detector with a kinetic inductance fraction of 0.45 changes the surface impedance of the resonator in response to incident THz radiation. The estimated optical noise equivalent power ( NEP ) is ∼0.23 pW · Hz −0.5 which shows about one order of magnitude improvement compared to that of the traditional voltage-biased NbN HEBs. The improved performance of the THz direct detectors with lower NEP and easy readout makes them promising in imaging with a large number of the array pixels.