Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Noise reduction in optically pumped magnetometer assemblies

V. Schultze, R.P.J. IJsselsteijn, H.‐G. Meyer

Published May 29, 2010• 24 citations
Publisher
DOI
10.1007/s00340-010-4084-9

Related papers

Origins of the intrinsic noise of zero-field metastable helium-4 optically pumped magnetometers

Alexandre Stathopulos, Rudy Romain, Sergey I. Mitryukovskiy +1 more

Physical Review A•Jul 7, 2026•0 citations

On an optically-pumped magnetometer and a rubidium frequency standard.

B.S. Mathur

•Jan 1, 1973•0 citations

Optically pumped magnetometers based on symmetric frequency-detuning modulated light

Yifan Yan, Zehua Liu, Yuesong Wu +4 more

Optics & Laser Technology•Mar 22, 2025•9 citations

Research of Magnetic Resonances Optical Detection Method in Optically Pumped Magnetometer

Zhang Zhen-yua

In the optically pumped magnetometer,the signal to noise ratio is very low when use the method of detecting Zeeman energy level transition directly.However,the detected signal to noise ratio can be greatly improved by using the technique of magnetic resonances optical detection which can transform the microwave quantum detection to the photon detection,because the energy of photon is much greater than that of microwave quantum.The method of magnetic resonances optical detection in the OPM(Optically Pumped Magnetometer) has been studied,the principles and experimental devices are discussed which includes the method of detection of cells transparency,detection of orthogonal beams,spin exchange collision and the method of pump beam modulation.The characteristics of these methods are analyzed and compared,the application and complexity are considered,and all these will provide the basis for the design of the optically pumped magnetometer.

Journal of Jilin University•Jan 1, 2011•0 citations

Magnetic communications with optically-pumped magnetometers and its relationship to multi-parameter quantum sensing

Morgan W. Mitchell

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Spin projection noise and the magnetic sensitivity of optically pumped magnetometers

K. Mouloudakis, V. Koutrouli, Iannis K. Kominis +2 more

Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.

arXiv:2402.10746•Feb 16, 2024•0 citations
In the optically pumped magnetometer,the signal to noise ratio is very low when use the method of detecting Zeeman energy level transition directly.However,the detected signal to noise ratio can be greatly improved by using the technique of magnetic resonances optical detection which can transform the microwave quantum detection to the photon detection,because the energy of photon is much greater than that of microwave quantum.The method of magnetic resonances optical detection in the OPM(Optically Pumped Magnetometer) has been studied,the principles and experimental devices are discussed which includes the method of detection of cells transparency,detection of orthogonal beams,spin exchange collision and the method of pump beam modulation.The characteristics of these methods are analyzed and compared,the application and complexity are considered,and all these will provide the basis for the design of the optically pumped magnetometer.
Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.