In the optically pumped magnetometer,the signal to noise ratio is very low when use the method of detecting Zeeman energy level transition directly.However,the detected signal to noise ratio can be greatly improved by using the technique of magnetic resonances optical detection which can transform the microwave quantum detection to the photon detection,because the energy of photon is much greater than that of microwave quantum.The method of magnetic resonances optical detection in the OPM(Optically Pumped Magnetometer) has been studied,the principles and experimental devices are discussed which includes the method of detection of cells transparency,detection of orthogonal beams,spin exchange collision and the method of pump beam modulation.The characteristics of these methods are analyzed and compared,the application and complexity are considered,and all these will provide the basis for the design of the optically pumped magnetometer.
In the optically pumped magnetometer,the signal to noise ratio is very low when use the method of detecting Zeeman energy level transition directly.However,the detected signal to noise ratio can be greatly improved by using the technique of magnetic resonances optical detection which can transform the microwave quantum detection to the photon detection,because the energy of photon is much greater than that of microwave quantum.The method of magnetic resonances optical detection in the OPM(Optically Pumped Magnetometer) has been studied,the principles and experimental devices are discussed which includes the method of detection of cells transparency,detection of orthogonal beams,spin exchange collision and the method of pump beam modulation.The characteristics of these methods are analyzed and compared,the application and complexity are considered,and all these will provide the basis for the design of the optically pumped magnetometer.
Significance Optically pumped magnetometers (OPMs) are crucial in magnetic-field measurements. Its high sensitivity and low noise allow it to detect weak magnetic-field changes up to the nT level, thus significantly expanding human understanding into the micro-magnetic-field environment. OPMs are beneficial in various areas, including the precise mapping of Earth’s magnetic field, the detection of weak biological magnetic signals within biological tissues, quantum computing, and magnetic-material research.The main function of an OPM is to detect magnetic fields using specific polarized pump light and detection light. High-purity pump light, which is typically linearly or circularly polarized, interacts with atomic cells. The selective excitation of pump light causes the arrangement of atomic magnetic moments to align with the polarization direction of light, thus forming a magnetized region. This process is known as optical pumping, which effectively places atoms in specific magnetic quantum states, thereby enhancing their sensitivity to magnetic fields. This allows the detection of light passing through magnetized regions with different polarization states. Under the effect of a magnetic field, the energy levels of atoms undergo Zeeman splitting, which affects the absorption and scattering of detection light. By analyzing and detecting changes in light intensity or polarization rotation, the intensity and direction of the magnetic field can be inferred accurately. The polarization state must be controlled precisely as it determines the manner by which atoms are excited and their response to magnetic fields, thereby ensuring the high sensitivity and measurement accuracy of the equipment. This principle based on atomic magnetic resonance renders the OPM an ideal tool for detecting weak magnetic fields; thus, OPMs are widely used in scientific research and practical applications.Aided by the development of modern technology, researchers have comprehensively investigated vector lights with complex polarization states and gradually applied them to OPMs. In an OPM, particularly the component involving the interaction between vector light and atoms, dichroism and birefringence are two key optical phenomena. Dichroism refers to the different propagation characteristics of light in different polarization directions. This characteristic is used to selectively excite or manipulate atoms of specific energy levels in an OPM. Birefringence refers to the difference in the refractive index between vertically and horizontally polarized light in a medium, which causes a beam to separate when it passes through an atomic medium. By leveraging the properties above and examining the practical application of vector light in OPMs, we can further improve the sensitivity of OPMs. Compared with conventional OPMs, a new type of OPM based on vector light pumping/detection features rapid response, adaptability to more complex environments, and high sensitivity. Owing to the vector characteristics of vector light, this OPM can simultaneously measure multiple components of the magnetic field, thus achieving complete magnetic-field vector measurements without requiring additional optical paths. Therefore, it is more suitable for integration into complex optical systems in fields such as biomedical, material science, and space exploration. Progress This paper summarizes the development history of OPMs, describes their operating principle (Figs. 2 and 3), and explains the energy-level transition of optically pumped polarized alkali metal atoms based on a 87Rb atomic energy-level diagram (Fig. 4). As per the development history of OPMs, optical polarization is crucial to the entire process (Fig. 5). Vector light is a new type of beam that has emerged in recent years, and its polarization state is distributed in a certain pattern on the cross-section of the beam (Fig. 6). The measurement of vector light in a magnetic field has been investigated extensively (Fig. 7). In terms of light and matter, investigating the dichroism and birefringence in the interaction between vector light and alkali metal atoms is crucial for OPMs. Based on dichroism, when a beam of linearly polarized light is irradiated onto an alkali metal atomic-gas chamber, the absorption and scattering efficiency of light varies owing to the ultrafine structure of the atoms and the energy levels of different magnetic quantum numbers. By adjusting the polarization direction of light, atoms can be more effectively pumped into specific magnetic states, thereby enhancing their response to magnetic fields (Fig. 8). Based on birefringence, vector light is incident in the orthogonal pumping direction, and the relationship between the polarization rotation angle of the detected light and the external magnetic field after the light passes through the gas chamber can be derived (Fig. 9). In practical applications, vector light with complex polarization states can be used as pump/detection light not only for the real-time dynamic detection of the magnetic-field size (Fig. 10) but also for solving the “dead zone” problem in magnetometers, improving spatial resolution and sensitivity (Fig. 11), and achieving miniaturized OPMs. Conclusions and Prospects Comprehensive investigations into quantum optics and the development of micro- and nano-technology will refine the manipulation of vector light, which is expected to enable magnetic-field measurements with higher sensitivities and resolutions. New OPMs based on vector optical pumping/detection have gradually received the attention of researchers. Thus, the application of OPMs in biomedicine, geological exploration, quantum information processing, and other fields will be promoted. Additionally, the miniaturization and integrated design of OPMs render them more portable and will further broaden their practical use. In the future, the development of vector-light technology will significantly improve OPMs.
Rubidium laser optically pumped magnetometers (OPMs) are widely used magnetic sensors based on the Zeeman effect, laser pumping, and magnetic resonance principles. They measure the magnetic field by measuring the magnetic resonance signal passing through a rubidium atomic gas cell. The quality of the magnetic resonance signal is a necessary condition for a magnetometer to achieve high sensitivity. In this research, to obtain the best magnetic resonance signal of rubidium laser OPMs in the Earth’s magnetic field intensity, the experiment system of rubidium laser OPMs is built with a rubidium atomic gas cell as the core component. The linewidth and amplitude ratio (LAR) of magnetic resonance signals is utilized as the optimization objective function. The magnetic resonance signals of the magnetometer experiment system are experimentally measured for different laser frequencies, radio frequency (RF) intensities, laser powers, and atomic gas cell temperatures in a background magnetic field of 50,765 nT. The experimental results indicate that optimizing these parameters can reduce the LAR by one order of magnitude. This shows that the optimal parameter combination can effectively improve the sensitivity of the magnetometer. The sensitivity defined using the noise spectral density measured under optimal experimental parameters is 1.5 pT/Hz1/2@1 Hz. This work will provide key technical support for rubidium laser OPMs’ product development.
The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.
Rb optically pumped magnetometer (OPM) based on electron paramagnetic resonance (EPR) show advantages to measure the nuclear magnetization and have succeeded in fundamental physics and rotation sensing, etc . The magnetometry sensitivity is a key performance of these Rb OPMs which should be improved. In this study, a high sensitivity Rb OPM is demonstrated theoretically and experimentally. To improve the sensitivity, acousto-optic modulation based on balanced detection is applied to suppress the probe noises. Compared with the conventional optical rotation detection for this OPM configuration, the probe noise shows a significant suppression especially in low frequencies. Eventually, a simultaneous dual-axis transverse measurement with 30 fT/Hz 1/2 sensitivity is achieved in a 200 Hz bandwidth and a 250nT linear working range. In addition, we utilize a closed-loop feedback to improve the stability and enlarge the transverse measurement range to 10µT order of magnitude while maintain the open-loop performances. A quasi-static magnetic field measurement can also be achieved in the longitudinal direction in the closed-loop mode. This OPM can serve for the nuclear magnetization measurement with a high sensitivity especially in environments with a large magnitude of the external magnetic field.
For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of ~1.2 kHz, and the sensitivity is calibrated to be ~245.5 pT/Hz1/2 only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be ~26.4 pT/Hz1/2 which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.
Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8pT/Hz 1/2 . Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9pT/Hz 1/2 , with a measured −3dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.