Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Impact of Phase-Sensitive-Amplifier’s Mode Structure on Amplified Image Quality

Muthiah Annamalai, Michael Vasilyev, Prem Kumar

Published Jan 1, 2012• 0 citations
Publisher

Abstract

We study phase-sensitive image pre-amplification versus pumping conditions and number of signal modes. We see image improvement by pre-amplification, and high-spatial-frequency enhancement for “higher-order-pump,” “nonzero-wavevector-mismatch” cases.
DOI
10.1364/cleo_si.2012.cf1b.7

Related papers

Spatial modes of phase-sensitive image amplifier with higher-order Gaussian pump and phase mismatch

Muthiah Annamalai, Nikolai M. Stelmakh, Michael Vasilyev +1 more

We compute eigenmodes of spatially-broadband optical parametric amplifier either with fundamental Hermite-Gaussian pump and phase mismatch Δk≠0, or with higher-order pump and Δk=0. Both cases are capable of shifting the maximum gain to higher-order modes.

IEEE Photonics Society Annual Meeting•Oct 1, 2011•2 citations

Phase-sensitive noiseless amplification and frequency conversion of spatially-multimode light

Muthiah Annamalai, Michael Vasilyev, Prem Kumar

We discuss the recent insights into the spatial-mode structure of traveling-wave optical parametric amplifiers, with focus on optical processing of quantum images.

IEEE/LEOS Summer Topical Meetings•Jul 1, 2013•0 citations

Optical Resolution Enhancement with Phase-Sensitive Preamplification

Oo-Kaw Lim, Gideon Alon, Zachary Dutton +3 more

We demonstrate enhanced resolution in image detection by phase-sensitive preamplification. In one-versus-two-target experiment we distinguish otherwise unresolved images with higher probability after such amplification than is possible without amplification.

Conference on Lasers and Electro-Optics•Jan 1, 2010•5 citations

Gain in Phase Sensitive Parametric Image Amplification

F. Devaux, Éric Lantz

We report an experiment of type 2 parametric image amplification in a phase sensitive configuration. In the spatial frequency domain, the parametric gain corresponds to amplification or deamplification, depending on the relative phase of the input image with respect to the pump wave and on the spatial frequencies of the input image.

Physical Review Letters•Sep 11, 2000•11 citations

Phase-sensitive parametric image amplification: application to noiseless image amplification

Fabrice Deveaux, Éric Lantz

We report semi-classical numeric simulations of the quantum spatial fluctuations in parametric amplification of images limited by the shot noise. Noiseless amplification of images is demonstrated by the use of a degenerate type 2 phase sensitive amplifier.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2001•0 citations

MODE STRUCTURE OF A NOISELESS PHASE-SENSITIVE IMAGE AMPLIFIER

Muthiah Annamalai

Optical parametric amplifiers (OPAs) configured as phase-sensitive amplifiers (PSAs) can be used for noiseless optical image amplification, generation of non-classical states of light, and, in particular, for multimode squeezed light generation. For all these applications and for effective use of the quantum properties of the multimode PSA, we need to know its independently squeezed (or amplified) eigenmodes. First we present the quantum theory of a spatially multimode traveling-wave PSA pumped by a high-power pump beam with arbitrary spatial profile. To quantitatively identify the Green's function of the PSA, we have developed a semi-analytical coupled-mode-theory of the PSA using 2D Hermite-Gaussian mode expansions of the signal- and pump-beam spatial distributions. By using Green's functions of the classical OPA, we calculate the normallyordered quadrature correlators at its output, which provide complete quantum description of the phase-sensitive OPA and enable determination of its independently squeezed eigenmodes. We find the number of the supported eigenmodes and their shapes for a spatially broadband frequency-degenerate optical parametric amplifier with elliptical Gaussian pump. We conclude by discussing our recent extensions of the coupled-mode-theory to study higher-order pump modes, compact representation of the PSA eigenmodes (especially convenient for experiments), and effect of non-zero phase mismatch on the PSA eigenmodes. We expect that the results from our model can be used for optimum mode matching in phase-sensitive image amplification and multimode squeezing generation.

•Apr 11, 2012•0 citations
Optical parametric amplifiers (OPAs) configured as phase-sensitive amplifiers (PSAs) can be used for noiseless optical image amplification, generation of non-classical states of light, and, in particular, for multimode squeezed light generation. For all these applications and for effective use of the quantum properties of the multimode PSA, we need to know its independently squeezed (or amplified) eigenmodes. First we present the quantum theory of a spatially multimode traveling-wave PSA pumped by a high-power pump beam with arbitrary spatial profile. To quantitatively identify the Green's function of the PSA, we have developed a semi-analytical coupled-mode-theory of the PSA using 2D Hermite-Gaussian mode expansions of the signal- and pump-beam spatial distributions. By using Green's functions of the classical OPA, we calculate the normallyordered quadrature correlators at its output, which provide complete quantum description of the phase-sensitive OPA and enable determination of its independently squeezed eigenmodes. We find the number of the supported eigenmodes and their shapes for a spatially broadband frequency-degenerate optical parametric amplifier with elliptical Gaussian pump. We conclude by discussing our recent extensions of the coupled-mode-theory to study higher-order pump modes, compact representation of the PSA eigenmodes (especially convenient for experiments), and effect of non-zero phase mismatch on the PSA eigenmodes. We expect that the results from our model can be used for optimum mode matching in phase-sensitive image amplification and multimode squeezing generation.