Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Low noise multiwasher superconducting interferometer

P. Carelli, Maria Gabriella Castellano, G. Torrioli, Roberto Leoni

Published Jan 5, 1998• 41 citations
Publisher

Abstract

The dc-superconducting quantum interference device (SQUID) is a low-noise converter from magnetic flux to voltage which can have, in principle, an energy sensitivity near the quantum limit of ℏ/2. A critical parameter for the ideal performance is the device inductance, which must be kept as small as possible. Minimizing the SQUID inductance, however, is a major concern for a practical device; this requirement implies a small SQUID ring and hence magnetic coupling with an external signal is more difficult to achieve. Here we present an original scheme (called multiwasher) to circumvent this problem, and its implementation in an all-refractory thin-film device. Our scheme not only provides good magnetic coupling with a large input coil (0.5 μH) and very low SQUID inductance, but also shielding from outside uniform fields, such as those generated by ambient disturbances. The measured coupled spectral energy sensitivity in the white region at about 1 kHz is 28ℏ at 4.2 K and 5.5ℏ in a pumped helium bath at 0.9 K. The flux noise spectral density at 0.1 Hz and 0.9 K is Φn=1×10−6 Φ0/Hz.

DOI
10.1063/1.121444

Related papers

Very low noise, tightly coupled, dc SQUID amplifiers

B. Muhlfelder, J. A. Beall, Michael W. Cromar +1 more

We have fabricated and tested thin film, niobium edge junction, double transformer, dc superconducting quantum interference devices (SQUID’s) that were stable under room-temperature storage and thermal cycling and that had very good noise performance. The input inductance, approximately 1.7 μH, was large enough to facilitate good matching to many experiments. When the SQUID was operated as a small-signal amplifier, the minimum detectable energy per unit bandwidth (Se) was 5×10−33 J/Hz at 100 kHz, referred to the SQUID loop (uncoupled). The minimum detectable energy per unit bandwidth was 1.8×10−31 J/Hz at 100 kHz, referred to the input coil. The SQUID’s had good characteristics for flux-locked operation since the small signal Se was low over a substantial range of bias current and magnetic flux. For operation in a flux-locked feedback circuit, Se was 6×10−32 J/Hz at 1 kHz.

Applied Physics Letters•Oct 27, 1986•19 citations

Ultra-low-noise tunnel junction dc SQUID with a tightly coupled planar input coil

M. B. Ketchen, J. M. Jaycox

We present a new superconducting quantum interference device (SQUID) that combines ultra-low-noise performance with tight coupling to a useable input coil. The inductive loop of the SQUID consists of a superconducting square washer that is slit in a low inductance fashion from its central hole to an outside edge where two Josephson tunnel junctions are incorporated. The inductance of the SQUID is about 90 pH, and each junction has a critical current of 15 μA and a resistive shunt of 4.5 Ω. The 190-nH input coil is a planar spiral of 50 turns situated immediately above the washer and coupled to the SQUID with a coupling constant k2 of 0.86. The SQUID has a minimum coupled energy sensitivity of 19h at 4.2 K and 8h at 1.5 K, in good agreement with theory. The crossover between white and low frequency noise occurs at ∼250 Hz.

Applied Physics Letters•Apr 15, 1982•248 citations

Low-noise tunnel junction dc SQUID’s

Michael W. Cromar, P. Carelli

We present the results of an investigation of thin-film dc super conducting quantum interference device (SQUID’s) with very high energy resolution. The SQUID’s were fabricated using integrated-circuit techniques appropriate for superconducting devices. A weakly coupled SQUID with very low inductance (1 pH) had an intrinsic energy sensitivity 6×10−34 J/Hz = 0.9 h. A well-coupled SQUID (coupling constant α = 0.43) had an energy sensitivity referred to the input coil of 4.7×10−32 J/Hz = 71 h.

Applied Physics Letters•May 1, 1981•87 citations

Strongly coupled, low noise dc-SQUID amplifiers

J. Pleikies

The dc Superconducting Quantum Interference Device (dc-SQUID) is one of the most sensitive magnetic field sensors available. In this thesis we concentrate on its application as an amplifier. In this configuration, an input circuit of interest can be connected by means of a coupling coil. The intended application of our developed low-Tc SQUID amplifiers is the readout of the first spherical gravitational wave antenna MiniGRAIL. Using small-signal analysis as well as numerical simulations, we study the achievable signal-to-noise ratio of such sensors in practical measurements. Published theories and studies could be extended. Some interesting points treated are the influence of the often used negative feedback (flux-locked loop), an altered input impedance of the SQUID amplifier and the influence of back-action noise, which directly affects the object of interest. The altered operation of the SQUID due to the presence of the input circuit is studied in numerical experiments. Another important issue, the influence of integrated input coils on the dynamics of SQUIDs, is investigated theoretically and experimentally. The performance of our developed sensors is compared to numerical simulations on detailed models. The results give insights into the behavior, design and usage of dc-SQUIDs with integrated coils. For a SQUID with input inductances of 1.5 μH we reached a good coupled energy sensitivity of about 170 ¯h in a dilution refrigerator. Furthermore, we investigated the hot-electron effect. This effect typically limits the sensitivity of superconducting electronics at sub-Kelvin bath temperatures due to a weakened electron-phonon coupling. We performed heating experiments on thin-film resistors which are similar to the shunt resistors of the Josephson junctions used in our sensors. The suppression of the hot-electron effect via electronic thermal transport to attached cooling fins is investigated both experimentally, theoretically and numerically. The numerical technique turns out to be a useful tool for the thermal design of superconducting electronics.

•Apr 1, 2009•0 citations

A coupled DC SQUID with low 1/f noise

Heikki Seppä, M. Kiviranta, Alexandre Satrapinski +3 more

A low-noise coupled DC superconducting quantum interference device (SQUID) especially optimized for low frequency is discussed. Using large Josephson junctions and a low loop inductance the contribution of the critical current fluctuation to 1/f noise can be minimized. To minimize the inductance the Josephson junctions are placed in the center of the washer close to the SQUID loop. A scaled-up copper model of the SQUID and the signal coil is used to analyze the impedance of the SQUID loop affected by the signal coil. An equivalent circuit model describing the effective inductance of the SQUID loop as a function of the frequency is used to design appropriate damping of the resonances. The DC SQUID characteristics are smooth and the noise performance of the SQUID does not markedly suffer from resonances. The contribution of the 1/f noise at 1 Hz is found to be about 5*10/sup -7/ Phi /sub 0// square root Hz.>

IEEE Transactions on Applied Superconductivity•Mar 1, 1993•25 citations

Reduction of 1/f noise in high-T c dc superconducting quantum interference devices cooled in an ambient magnetic field

E. Dantsker, Saburo Tanaka, P.-Å. Nilsson +2 more

The spectral density SΦ(f ) of the low-frequency 1/f noise of high transition temperature dc superconducting quantum interference devices (SQUIDs) with narrow linewidths was independent of B0, the magnetic field in which they were cooled, up to a threshold value, about 33 μT in the best case. Above this threshold, which is associated with the entry of flux vortices into the film, the noise increased rapidly. By contrast, for large square washer SQUIDs, SΦ(f ) scaled linearly with B0. Estimates indicate that the 1/f flux noise produced by the pickup loop of a directly coupled magnetometer is negligible.

Applied Physics Letters•Dec 23, 1996•102 citations
The dc-superconducting quantum interference device (SQUID) is a low-noise converter from magnetic flux to voltage which can have, in principle, an energy sensitivity near the quantum limit of ℏ/2. A critical parameter for the ideal performance is the device inductance, which must be kept as small as possible. Minimizing the SQUID inductance, however, is a major concern for a practical device; this requirement implies a small SQUID ring and hence magnetic coupling with an external signal is more difficult to achieve. Here we present an original scheme (called multiwasher) to circumvent this problem, and its implementation in an all-refractory thin-film device. Our scheme not only provides good magnetic coupling with a large input coil (0.5 μH) and very low SQUID inductance, but also shielding from outside uniform fields, such as those generated by ambient disturbances. The measured coupled spectral energy sensitivity in the white region at about 1 kHz is 28ℏ at 4.2 K and 5.5ℏ in a pumped helium bath at 0.9 K. The flux noise spectral density at 0.1 Hz and 0.9 K is Φn=1×10−6 Φ0/Hz.
We have fabricated and tested thin film, niobium edge junction, double transformer, dc superconducting quantum interference devices (SQUID’s) that were stable under room-temperature storage and thermal cycling and that had very good noise performance. The input inductance, approximately 1.7 μH, was large enough to facilitate good matching to many experiments. When the SQUID was operated as a small-signal amplifier, the minimum detectable energy per unit bandwidth (Se) was 5×10−33 J/Hz at 100 kHz, referred to the SQUID loop (uncoupled). The minimum detectable energy per unit bandwidth was 1.8×10−31 J/Hz at 100 kHz, referred to the input coil. The SQUID’s had good characteristics for flux-locked operation since the small signal Se was low over a substantial range of bias current and magnetic flux. For operation in a flux-locked feedback circuit, Se was 6×10−32 J/Hz at 1 kHz.
We present a new superconducting quantum interference device (SQUID) that combines ultra-low-noise performance with tight coupling to a useable input coil. The inductive loop of the SQUID consists of a superconducting square washer that is slit in a low inductance fashion from its central hole to an outside edge where two Josephson tunnel junctions are incorporated. The inductance of the SQUID is about 90 pH, and each junction has a critical current of 15 μA and a resistive shunt of 4.5 Ω. The 190-nH input coil is a planar spiral of 50 turns situated immediately above the washer and coupled to the SQUID with a coupling constant k2 of 0.86. The SQUID has a minimum coupled energy sensitivity of 19h at 4.2 K and 8h at 1.5 K, in good agreement with theory. The crossover between white and low frequency noise occurs at ∼250 Hz.
We present the results of an investigation of thin-film dc super conducting quantum interference device (SQUID’s) with very high energy resolution. The SQUID’s were fabricated using integrated-circuit techniques appropriate for superconducting devices. A weakly coupled SQUID with very low inductance (1 pH) had an intrinsic energy sensitivity 6×10−34 J/Hz = 0.9 h. A well-coupled SQUID (coupling constant α = 0.43) had an energy sensitivity referred to the input coil of 4.7×10−32 J/Hz = 71 h.
The dc Superconducting Quantum Interference Device (dc-SQUID) is one of the most sensitive magnetic field sensors available. In this thesis we concentrate on its application as an amplifier. In this configuration, an input circuit of interest can be connected by means of a coupling coil. The intended application of our developed low-Tc SQUID amplifiers is the readout of the first spherical gravitational wave antenna MiniGRAIL. Using small-signal analysis as well as numerical simulations, we study the achievable signal-to-noise ratio of such sensors in practical measurements. Published theories and studies could be extended. Some interesting points treated are the influence of the often used negative feedback (flux-locked loop), an altered input impedance of the SQUID amplifier and the influence of back-action noise, which directly affects the object of interest. The altered operation of the SQUID due to the presence of the input circuit is studied in numerical experiments. Another important issue, the influence of integrated input coils on the dynamics of SQUIDs, is investigated theoretically and experimentally. The performance of our developed sensors is compared to numerical simulations on detailed models. The results give insights into the behavior, design and usage of dc-SQUIDs with integrated coils. For a SQUID with input inductances of 1.5 μH we reached a good coupled energy sensitivity of about 170 ¯h in a dilution refrigerator. Furthermore, we investigated the hot-electron effect. This effect typically limits the sensitivity of superconducting electronics at sub-Kelvin bath temperatures due to a weakened electron-phonon coupling. We performed heating experiments on thin-film resistors which are similar to the shunt resistors of the Josephson junctions used in our sensors. The suppression of the hot-electron effect via electronic thermal transport to attached cooling fins is investigated both experimentally, theoretically and numerically. The numerical technique turns out to be a useful tool for the thermal design of superconducting electronics.
A low-noise coupled DC superconducting quantum interference device (SQUID) especially optimized for low frequency is discussed. Using large Josephson junctions and a low loop inductance the contribution of the critical current fluctuation to 1/f noise can be minimized. To minimize the inductance the Josephson junctions are placed in the center of the washer close to the SQUID loop. A scaled-up copper model of the SQUID and the signal coil is used to analyze the impedance of the SQUID loop affected by the signal coil. An equivalent circuit model describing the effective inductance of the SQUID loop as a function of the frequency is used to design appropriate damping of the resonances. The DC SQUID characteristics are smooth and the noise performance of the SQUID does not markedly suffer from resonances. The contribution of the 1/f noise at 1 Hz is found to be about 5*10/sup -7/ Phi /sub 0// square root Hz.>
The spectral density SΦ(f ) of the low-frequency 1/f noise of high transition temperature dc superconducting quantum interference devices (SQUIDs) with narrow linewidths was independent of B0, the magnetic field in which they were cooled, up to a threshold value, about 33 μT in the best case. Above this threshold, which is associated with the entry of flux vortices into the film, the noise increased rapidly. By contrast, for large square washer SQUIDs, SΦ(f ) scaled linearly with B0. Estimates indicate that the 1/f flux noise produced by the pickup loop of a directly coupled magnetometer is negligible.