Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum and Semiclassical Optics Journal of the European Optical Society Part B

Quantum noise in optical parametric amplification: a means to achieve noiseless optical functions

Juan Ariel Levenson, Kamel Bencheikh, D. J. Lovering, P. Vidaković, C. Simonneau

Published Apr 1, 1997• 27 citations
Publisher

Abstract

We describe some limitations of the noise performance of classical optical devices which are directly related to the Poissonian statistics associated with ordinary laser beams. We show that quantum optics, via optical parametric amplification, allows us to circumvent these limitations in order to realize certain noiseless optical functions such as amplification, duplication, detection and distribution of optical signals.

DOI
10.1088/1355-5111/9/2/009

Related papers

Quantum noise reduction in quasi-phase-matched optical parametric amplification

Kamel Bencheikh, E. Huntziger, Juan Ariel Levenson

We present a calculation of quantum noise for parametric amplification in periodically inverted nonlinear media. An analytical expression is obtained for the noise figure of the amplifier. We show that such optical parametric amplifiers run in a phase-sensitive configuration can achieve noiseless amplification and squeezing, thus constituting a promising way for the integration of noiseless optical amplifiers in a communication line.

Journal of the Optical Society of America B•May 1, 1995•31 citations

Parametric Amplification, Duplication and Frequency Conversion of Optical Signals

Colin J. McKinstrie

I will review the physics of parametric amplification and frequency conversion, and describe three recent applications of parametric devices: (a) low-noise four-fold multicasting, (b) hybrid amplification and (c) quantum-state-preserving frequency conversion for quantum communication systems.

Asia Communications and Photonics Conference•Jan 1, 2013•0 citations

Photonic Quantum Noise Reduction with Low-Pump Parametric Amplifiers for Photonic Integrated Circuits

Andre Vatarescu

An approximation-free and fully quantum optic formalism for parametric processes is presented. Phase-dependent gain coefficients and related phase-pulling effects are identified for quantum Rayleigh emission and the electro-optic conversion of photons providing parametric amplification in small-scale integration of photonic devices. These mechanisms can be manipulated to deliver, simultaneously, sub-Poissonian distributions of photons as well as phase-dependent amplification in the same optical quadrature of a signal field.

Photonics•Nov 26, 2016•17 citations

Quantum fluctuations in traveling-wave amplification of optical images

I. V. Sokolov, Mikhail I. Kolobov, Luigi Lugiato

We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently for a cavity-based geometry, such a scheme can amplify images without deteriorating their signal-to-noise ratio thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We study in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. We investigate physical features of noiseless amplification, which take place for both traveling-wave and ring-cavity configurations. We demonstrate how the optimum phase matching of a phase-sensitive wave front of an image (by means of a thin lens or a small displacement of the crystal) can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the possibility of using detectors with the area much smaller than the area of the input image elements. We compare our results with those obtained for the ring-cavity configuration.

Physical Review A•Sep 1, 1999•35 citations

Observation of Noiseless Image Amplification by an Optical Parametric Amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

A spatially-broadband optical parametric amplifier is used for image amplification. In the phase-sensitive configuration, we observe a noise figure of −0.1± 0.3dB for a gain of 2.4, which is 2dB lower than the quantum limit for an ideal phase-insensitive amplifier. Image pre-amplification before loss is shown to improve the detected signal-to-noise ratio.

Kluwer Academic Publishers eBooks•Dec 19, 2005•1 citation

Quantum Imaging: Fundamentals And Promises

Mikhail I. Kolobov

Quantum imaging can be defined as an area of quantum optics that investigates the ultimate performance limits of optical imaging allowed by the quantum nature of light. Quantum Imaging techniques possess a high potential for improving the performance in recording, storage, and readout of optical images beyond the limits set by the standard quantum level of fluctuations known as the shot noise. This talk aims at giving an overview of the fundamentals of Quantum Imaging as well as its most important directions. We shall discuss generation of the spatially multimode squeezed states of light be means of a travelling-wave optical parametric amplifier. We shall demonstrate that this kind of light allows us to reduce the spatial fluctuations of the photocurrent in a properly chosen homodyne detection scheme with a highly efficient CCD camera. It will be shown that using the amplified quadrature of the light wave in a travelling-wave optical parametric amplifier, one can perform noiseless amplification of optical images. We shall provide recent experimental results demonstrating a single-shot noiseless image amplification by a pulsed optical parametric amplifier. One of important experimental achievements of Quantum Imaging, coined in the literature as quantum laser pointer, is a precise measurement of position and transverse displacement of a laser beam with resolution beyond the limit imposed by the shot noise. We shall describe briefly the idea of the experiment in which the transverse displacement of a laser beam was measured with resolution of the order of Angstrom. The problem of precise measurement of transverse displacement of a light beam brings us to a more general question about the quantum limits of optical resolution. The classical resolution criterion, derived in the nineteen century by Abbe and Rayleigh, states that the resolution of an optical instrument is limited by diffraction and is related to the wavelength of the light used in the imaging scheme. However, it was for a long time recognised in the literature that in some cases when one has some a priori information about the object, one can improve the resolution beyond the Rayleigh limit using the so-called super-resolution techniques. As a final topic in this talk, we shall discuss the quantum limits of optical super-resolution. In particular, we shall formulate the standard quantum limit of super-resolution and demonstrate how one can go beyond this limit using specially designed multimode squeezed light.

Qatar Foundation Annual Research Forum Volume 2013 Issue 1•Jan 1, 2013•0 citations
We describe some limitations of the noise performance of classical optical devices which are directly related to the Poissonian statistics associated with ordinary laser beams. We show that quantum optics, via optical parametric amplification, allows us to circumvent these limitations in order to realize certain noiseless optical functions such as amplification, duplication, detection and distribution of optical signals.
An approximation-free and fully quantum optic formalism for parametric processes is presented. Phase-dependent gain coefficients and related phase-pulling effects are identified for quantum Rayleigh emission and the electro-optic conversion of photons providing parametric amplification in small-scale integration of photonic devices. These mechanisms can be manipulated to deliver, simultaneously, sub-Poissonian distributions of photons as well as phase-dependent amplification in the same optical quadrature of a signal field.
We investigate amplification of optical images by means of a traveling-wave optical parametric amplifier. As shown recently for a cavity-based geometry, such a scheme can amplify images without deteriorating their signal-to-noise ratio thus working as a noiseless amplifier. Here we consider a configuration without cavity, which is more realistic for a possible experimental realization. We study in detail the quantum fluctuations of the amplifier and formulate criteria for its noiseless performance. We investigate physical features of noiseless amplification, which take place for both traveling-wave and ring-cavity configurations. We demonstrate how the optimum phase matching of a phase-sensitive wave front of an image (by means of a thin lens or a small displacement of the crystal) can improve the noise performance of the amplifier and bring it to the ultimate value achievable under given physical conditions. We discuss the possibility of using detectors with the area much smaller than the area of the input image elements. We compare our results with those obtained for the ring-cavity configuration.
Quantum imaging can be defined as an area of quantum optics that investigates the ultimate performance limits of optical imaging allowed by the quantum nature of light. Quantum Imaging techniques possess a high potential for improving the performance in recording, storage, and readout of optical images beyond the limits set by the standard quantum level of fluctuations known as the shot noise. This talk aims at giving an overview of the fundamentals of Quantum Imaging as well as its most important directions. We shall discuss generation of the spatially multimode squeezed states of light be means of a travelling-wave optical parametric amplifier. We shall demonstrate that this kind of light allows us to reduce the spatial fluctuations of the photocurrent in a properly chosen homodyne detection scheme with a highly efficient CCD camera. It will be shown that using the amplified quadrature of the light wave in a travelling-wave optical parametric amplifier, one can perform noiseless amplification of optical images. We shall provide recent experimental results demonstrating a single-shot noiseless image amplification by a pulsed optical parametric amplifier. One of important experimental achievements of Quantum Imaging, coined in the literature as quantum laser pointer, is a precise measurement of position and transverse displacement of a laser beam with resolution beyond the limit imposed by the shot noise. We shall describe briefly the idea of the experiment in which the transverse displacement of a laser beam was measured with resolution of the order of Angstrom. The problem of precise measurement of transverse displacement of a light beam brings us to a more general question about the quantum limits of optical resolution. The classical resolution criterion, derived in the nineteen century by Abbe and Rayleigh, states that the resolution of an optical instrument is limited by diffraction and is related to the wavelength of the light used in the imaging scheme. However, it was for a long time recognised in the literature that in some cases when one has some a priori information about the object, one can improve the resolution beyond the Rayleigh limit using the so-called super-resolution techniques. As a final topic in this talk, we shall discuss the quantum limits of optical super-resolution. In particular, we shall formulate the standard quantum limit of super-resolution and demonstrate how one can go beyond this limit using specially designed multimode squeezed light.