Journal of Optics B Quantum and Semiclassical Optics

Optimization and transfer of vacuum squeezing from an optical parametric oscillator

Ping Koy Lam, Timothy C. Ralph, B. C. Buchler, David E. McClelland, Hans‐A. Bachor, Jiangrui Gao

Published Aug 1, 1999• 105 citations
Publisher

Abstract

We report the observation of more than 7 dB of vacuum squeezing from a below-threshold optical parametric oscillator (OPO). We discuss design criteria and experimental considerations for its optimization and demonstrate that the vacuum squeezing can be electro-optically transferred to a bright beam using a feed-forward loop. This is compared with the bright intensity squeezed beam generated by running the OPO as a de-amplifier.

DOI
10.1088/1464-4266/1/4/319

Related papers

Generation, transfer, and application of a squeezed vacuum

Ping Koy Lam, Timothy C. Ralph, B. C. Buchler +3 more

The limits and requisites to large observable squeezing from a below threshold optical parametric oscillator (OPO) are presented including the more than 7 dB of quadrature squeezing measured from the vacuum output of a below threshold OPO. Two method of transferring the vacuum squeezing onto a bright beam using the squeezed vacuum system are examined.

Quantum Electronics and Laser Science Conference•Jan 20, 2003•0 citations

Reservoir-Engineered Squeezed Lasing through the Parametric Coupling

Yuhang Tian, Yajun Wang, Weijie Wang +5 more

We report the first experimental demonstration of squeezed lasing in a reservoir-engineered optical parametric oscillator (OPO). The OPO provides a basis of squeezed states and parametric amplification in lasing emission, whose vacuum reservoir is coupled to a squeezed vacuum generated by a second OPO. With a precisely controlled squeezing angle and strong squeezing injection, the parametric interaction in the first OPO is exponentially enhanced. It successfully circumvents the decoherence in the system, and eliminates the undesired noise of spontaneous photon emission in the OPO. As a result, the amplified parametric process simultaneously reserves the coherence and quantum properties in the first OPO, and yields a -6.1 dB squeezed laser in optical domain with a narrow linewidth and high brightness. Our work sheds light on potential applications of squeezed lasing in quantum metrology and quantum optics.

arXiv:2507.05708•Physical Review Letters•May 23, 2025•18 citations

Generation and measurement of a squeezed vacuum up to 100 MHz at 1550 nm with a semi-monolithic optical parametric oscillator designed towards direct coupling with waveguide modules

Naoto Takanashi, Wataru Inokuchi, Takahiro Serikawa +1 more

We report generation and measurement of a squeezed vacuum from a semi-monolithic Fabry-Pérot optical parametric oscillator (OPO) up to 100 MHz at 1550 nm. The output coupler of the OPO is a flat surface of a nonlinear crystal with partially reflecting coating, which enables direct coupling with waveguide modules. Using the OPO, we observed 6.2dB of squeezing at 2 MHz and 3.0 dB of squeezing at 100 MHz. The OPO operates at the optimal wavelength to minimize propagation losses in silica waveguides and looks towards solving a bottleneck of downsizing these experiments: that of coupling between a squeezer and a waveguide.

arXiv:1904.09777•Optics Express•Jun 20, 2019•23 citations

Characteristics of bright-squeezed light produced in a below-threshold optical parametric oscillator

E G Lariontsev, I I Zolotoverkh

We perform a theoretical analysis of steady-state solutions and quantum noise in a below-threshold optical parametric oscillator (OPO) operating as an amplifier with an input seed wave. Both the amplitude-squeezed and phase-squeezed states of the output field are considered. We take into account the intracavity nonlinear losses due to intracavity frequency doubling of the signal wave and the quantum fluctuations of the seed and pump waves. Unlike the preceding theoretical studies of the problem, we show that squeezing in bright beams produced by the OPO depends on their intensity. For the amplitude-squeezed state, squeezing strongly degrades with increasing output intensity. In contrast, one can obtain good squeezing for phase-squeezed beams of high output intensity.

Journal of Optics B Quantum and Semiclassical Optics•Jan 8, 2002•10 citations

Fundamental limits to the generation of highly displaced bright squeezed light using linear optics and parametric amplifiers

Steve M. Young, Daniel Soh

High-quality squeezed light is an important resource for a variety of applications. Multiple methods for generating squeezed light are known, having been demonstrated theoretically and experimentally. However, the effectiveness of these methods—in particular, the inherent limitations to the signals that can be produced—has received little consideration. Here we present a comparative theoretical analysis for generating a highly displaced squeezed light from a linear optical method—a beamsplitter mixing a squeezed vacuum and a strong coherent state—and well-studied parametric amplification methods including an optical parametric oscillator, an optical parametric amplifier, and a dissipative optomechanical squeezer seeded with coherent states. We show that the quality of highly displaced squeezed states that can be generated using these methods is limited on a fundamental level by the physical mechanism utilized; across all methods there are significant trade-offs between displacement, squeezing, and overall uncertainty. We explore the nature and extent of these trade-offs specific to each mechanism and identify the optimal operation modes for each. Finally, we identify the conditions for minimum-uncertainty squeezing in arbitrary parametric amplifying systems and show that displacing the output signal will in general violate these conditions, adding noise and degrading squeezing.

arXiv:2311.08641•Physical Review Research•Feb 3, 2025•2 citations

Observation of On-Chip Optical Squeezing

Avik Dutt, Kevin J. Luke, Sasikanth Manipatruni +3 more

We report the first demonstration of on-chip optical squeezing in a CMOS compatible integrated SiN ring resonator optical parametric oscillator operating above threshold. We measure 1.7 dB intensity-difference squeezing between bright signal and idler beams.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2013•2 citations
We report the observation of more than 7 dB of vacuum squeezing from a below-threshold optical parametric oscillator (OPO). We discuss design criteria and experimental considerations for its optimization and demonstrate that the vacuum squeezing can be electro-optically transferred to a bright beam using a feed-forward loop. This is compared with the bright intensity squeezed beam generated by running the OPO as a de-amplifier.
We report the first experimental demonstration of squeezed lasing in a reservoir-engineered optical parametric oscillator (OPO). The OPO provides a basis of squeezed states and parametric amplification in lasing emission, whose vacuum reservoir is coupled to a squeezed vacuum generated by a second OPO. With a precisely controlled squeezing angle and strong squeezing injection, the parametric interaction in the first OPO is exponentially enhanced. It successfully circumvents the decoherence in the system, and eliminates the undesired noise of spontaneous photon emission in the OPO. As a result, the amplified parametric process simultaneously reserves the coherence and quantum properties in the first OPO, and yields a -6.1 dB squeezed laser in optical domain with a narrow linewidth and high brightness. Our work sheds light on potential applications of squeezed lasing in quantum metrology and quantum optics.
We report generation and measurement of a squeezed vacuum from a semi-monolithic Fabry-Pérot optical parametric oscillator (OPO) up to 100 MHz at 1550 nm. The output coupler of the OPO is a flat surface of a nonlinear crystal with partially reflecting coating, which enables direct coupling with waveguide modules. Using the OPO, we observed 6.2dB of squeezing at 2 MHz and 3.0 dB of squeezing at 100 MHz. The OPO operates at the optimal wavelength to minimize propagation losses in silica waveguides and looks towards solving a bottleneck of downsizing these experiments: that of coupling between a squeezer and a waveguide.
We perform a theoretical analysis of steady-state solutions and quantum noise in a below-threshold optical parametric oscillator (OPO) operating as an amplifier with an input seed wave. Both the amplitude-squeezed and phase-squeezed states of the output field are considered. We take into account the intracavity nonlinear losses due to intracavity frequency doubling of the signal wave and the quantum fluctuations of the seed and pump waves. Unlike the preceding theoretical studies of the problem, we show that squeezing in bright beams produced by the OPO depends on their intensity. For the amplitude-squeezed state, squeezing strongly degrades with increasing output intensity. In contrast, one can obtain good squeezing for phase-squeezed beams of high output intensity.
High-quality squeezed light is an important resource for a variety of applications. Multiple methods for generating squeezed light are known, having been demonstrated theoretically and experimentally. However, the effectiveness of these methods—in particular, the inherent limitations to the signals that can be produced—has received little consideration. Here we present a comparative theoretical analysis for generating a highly displaced squeezed light from a linear optical method—a beamsplitter mixing a squeezed vacuum and a strong coherent state—and well-studied parametric amplification methods including an optical parametric oscillator, an optical parametric amplifier, and a dissipative optomechanical squeezer seeded with coherent states. We show that the quality of highly displaced squeezed states that can be generated using these methods is limited on a fundamental level by the physical mechanism utilized; across all methods there are significant trade-offs between displacement, squeezing, and overall uncertainty. We explore the nature and extent of these trade-offs specific to each mechanism and identify the optimal operation modes for each. Finally, we identify the conditions for minimum-uncertainty squeezing in arbitrary parametric amplifying systems and show that displacing the output signal will in general violate these conditions, adding noise and degrading squeezing.