Microfabricated saturated absorption laser spectrometer

Svenja A. Knappe, H. G. Robinson, Leo W. Hollberg

Published Jan 1, 2007• 50 citations
Publisher

Abstract

We demonstrate a miniature microfabricated saturated absorption laser spectrometer. The system consists of miniature optics, a microfabricated Rb vapor cell, heaters, and a photodetector, all contained within a volume of 0.1 cm(3). Saturated absorption spectra were measured with a diode laser at 795 nm. They are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm(3). We discuss the performance and prospects for using such systems as a miniature optical wavelength reference, compatible with transportable instruments.

DOI
10.1364/oe.15.006293

Related papers

Miniature laser frequency stabilization module for cold atom sensing

Qingzhe Gou, Ning Wei, Haixu Tao +4 more

In this study, a miniature laser frequency stabilization module for cold atom sensing applications was designed and realized.The module can lock the laser frequency to the saturated absorption spectrum of the D2 line of rubidium (Rb) atoms using the frequency modulation spectroscopy method.The module core is a tiny Rb cell, co-packaged with the saturation absorption optical setup, temperature control circuit, and detection circuit through a joint optical-mechanical-electrical design for a total volume of only 40 mm × 15 mm × 30 mm.The frequency fluctuation of the 780 nm laser after frequency stabilization by the module was within 1 MHz over 1000 s, which is adequate for magneto-optical trap experiments.The results verify the feasibility of the module as a frequency reference and provide a light source for portable cold atom sensing devices.

Chinese Optics Letters•Jan 1, 2024•1 citation

A wavelength reference at 1560 nm using a photonic rubidium spectrometer and aluminum nitride microresonator frequency doubler (Conference Presentation)

Casey McKenna, Douglas G. Bopp, Zach L. Newman +8 more

Wavelength references in the telecom spectrum have applications in communications and dimensional metrology. However, they typically consist of bulk optics and vapor cells. Photonic integration of these components may lead to low cost, portable devices. Here we demonstrate the incorporation of a photonic Rb spectrometer with an AlN microresonator frequency doubler. Light at 1560 nm is coupled onto a chip containing the AlN microresonator frequency doubler. The resulting 780 nm light is sent to the photonic Rb spectrometer, which consists of an apodized grating beam expander and microfabricated MEMS vapor cell. We perform Doppler broadened spectroscopy of the D2 line and demonstrate preliminary laser stabilization to these features.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2020•0 citations

Saturated absorption spectroscopy of the Cs atom 6S1/2 → 7P1/2 transition at 459 nm in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar +3 more

Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.

•Sep 30, 2024•0 citations

Laser frequency stabilization using a spatially multiplexed microfabricated Rb vapor cell

Seji Kang, Soyeon Choi, Jaeuk Baek +10 more

Abstract We demonstrate a laser stabilization based on a spatially-multiplexed, microfabricated rubidium vapor cell. This design integrates multiple optical apertures within a cell, enabling a single input beam to simultaneously capture both Doppler-broadened and saturated absorption spectroscopy signals while a dedicated non-absorbing aperture directs the beam toward the physics package. We achieve a frequency stability of 4 × 10 −13 at 100 s, and partial correction of the Doppler background allows the system to remain stable at the 10 −12 -level up to 10 4 s. This architecture significantly reduces optical complexity while providing a robust, high-performance laser source for deployable quantum sensors.

Applied Physics Express•Apr 1, 2026•0 citations

Laser cooling of rubidium atoms in a vapor cell

H. Ludvigsen, A. Äijälä, A. Pietiläinen +2 more

We have constructed a simplified setup for the demonstration of laser cooling and trapping of rubidium atoms. An external-cavity diode laser was swept across the F = 3 → F' = 2, 3, 4 resonances of the D 2 -line of 85 Rb at 780 nm to resolve the saturated absorption features. Subsequently, the transition F = 3 → F' = 4 was used to cool rubidium atoms in a roomtemperature vapor cell. A cold cloud of trapped atoms with a diameter of approximately 1 mm was produced. The lifetime of the trap was measured to be 1 second.

Physica Scripta•Apr 1, 1994•7 citations

Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

Vinu Venkatraman, Songbai Kang, C. Affolderbach +2 more

Miniature (<few cm3) vapor-cell based devices using optical pumping of alkali atoms, such as atomic clocks and magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm3 as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm3 volume) test setup based on the Mz magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.

Applied Physics Letters•Feb 3, 2014•15 citations
We demonstrate a miniature microfabricated saturated absorption laser spectrometer. The system consists of miniature optics, a microfabricated Rb vapor cell, heaters, and a photodetector, all contained within a volume of 0.1 cm(3). Saturated absorption spectra were measured with a diode laser at 795 nm. They are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm(3). We discuss the performance and prospects for using such systems as a miniature optical wavelength reference, compatible with transportable instruments.
In this study, a miniature laser frequency stabilization module for cold atom sensing applications was designed and realized.The module can lock the laser frequency to the saturated absorption spectrum of the D2 line of rubidium (Rb) atoms using the frequency modulation spectroscopy method.The module core is a tiny Rb cell, co-packaged with the saturation absorption optical setup, temperature control circuit, and detection circuit through a joint optical-mechanical-electrical design for a total volume of only 40 mm × 15 mm × 30 mm.The frequency fluctuation of the 780 nm laser after frequency stabilization by the module was within 1 MHz over 1000 s, which is adequate for magneto-optical trap experiments.The results verify the feasibility of the module as a frequency reference and provide a light source for portable cold atom sensing devices.
Wavelength references in the telecom spectrum have applications in communications and dimensional metrology. However, they typically consist of bulk optics and vapor cells. Photonic integration of these components may lead to low cost, portable devices. Here we demonstrate the incorporation of a photonic Rb spectrometer with an AlN microresonator frequency doubler. Light at 1560 nm is coupled onto a chip containing the AlN microresonator frequency doubler. The resulting 780 nm light is sent to the photonic Rb spectrometer, which consists of an apodized grating beam expander and microfabricated MEMS vapor cell. We perform Doppler broadened spectroscopy of the D2 line and demonstrate preliminary laser stabilization to these features.
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.
Abstract We demonstrate a laser stabilization based on a spatially-multiplexed, microfabricated rubidium vapor cell. This design integrates multiple optical apertures within a cell, enabling a single input beam to simultaneously capture both Doppler-broadened and saturated absorption spectroscopy signals while a dedicated non-absorbing aperture directs the beam toward the physics package. We achieve a frequency stability of 4 × 10 −13 at 100 s, and partial correction of the Doppler background allows the system to remain stable at the 10 −12 -level up to 10 4 s. This architecture significantly reduces optical complexity while providing a robust, high-performance laser source for deployable quantum sensors.
We have constructed a simplified setup for the demonstration of laser cooling and trapping of rubidium atoms. An external-cavity diode laser was swept across the F = 3 → F' = 2, 3, 4 resonances of the D 2 -line of 85 Rb at 780 nm to resolve the saturated absorption features. Subsequently, the transition F = 3 → F' = 4 was used to cool rubidium atoms in a roomtemperature vapor cell. A cold cloud of trapped atoms with a diameter of approximately 1 mm was produced. The lifetime of the trap was measured to be 1 second.
Miniature (<few cm3) vapor-cell based devices using optical pumping of alkali atoms, such as atomic clocks and magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm3 as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm3 volume) test setup based on the Mz magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.