Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Saturated absorption spectroscopy of the Cs atom 6S1/2 → 7P1/2 transition at 459 nm in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar, Rémy Vicarini, Nicolas Passilly, Rodolphe Boudot

Published Sep 30, 2024• 0 citations
OpenAlex

Abstract

Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.

Related papers

Sub-Doppler spectroscopy of the Cs atom 6S1/2–7P1/2 transition at 459 nm in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar +3 more

We report on the characterization of sub-Doppler resonances detected by probing the 6S1/2 - 7P1/2 transition of the Cs atom at 459 nm in a microfabricated vapor cell. The dependence of the sub-Doppler resonance (linewidth, amplitude) on some key experimental parameters, including the laser intensity and the cell temperature, is investigated. These narrow atomic resonances are of interest for high-resolution spectroscopy and instrumentation and may constitute the basis of a high-stability microcell optical standard.

Optics Letters•Mar 5, 2024•16 citations

Advances in microfabricated vapor cells for chip-scale atomic clocks and sensors

Andrei Mursa, G. Faure, Clément Carlé +16 more

We summarize activities performed at FEMTO-ST Institute and Centrale Lille/IEMN over the last years on the development of microfabricated vapor cells dedicated to atomic clocks, frequency references and sensors. Recent advances on the microcell technology are described. We have demonstrated CPT-based microwave clocks with stability in the low 10−12 range thanks to the implementation of advanced pulsed Ramsey-based interrogation sequences and cells built with low-permeation glass substrates and Al2O3 coatings. We have developed microcell optical frequency references, one based on the two-photon transition of Rb atom at 778 nm and one on saturated absorption of the 6S1/2-7P1/2 transition of Cs atom at 459 nm, with short-term stability levels in the low 10−13 range at 1 s and averaging down in the low 10−14 range after 100 s. Optically pumped magnetometers with sensitivity at the level of 100 fT/√Hz have also been demonstrated. In-progress studies, on both the cell technology and metrology aspects, are also discussed.

•Sep 14, 2026•0 citations

Sub-Doppler spectroscopy of the near-UV Cs atom 6S$_{1/2}$-7P$_{1/2}$ transition in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar +3 more

We report on the characterization of sub-Doppler resonances detected by probing the 6S$_{1/2}$-7P$_{1/2}$ transition of Cs atom at 459 nm in a microfabricated vapor cell. The dependence of the sub-Doppler resonance (linewidth, amplitude) on some key experimental parameters, including the laser intensity and the cell temperature, is investigated. These narrow atomic resonances are of interest for high-resolution spectroscopy, instrumentation, and may constitute the basis of a near-UV microcell optical standard.

arXiv:2311.18459•Nov 30, 2023•0 citations

Short-term stability of Cs microcell-stabilized lasers using dual-frequency sub-Doppler spectroscopy

Anthony Gusching, M. Petersen, Nicolas Passilly +3 more

The combination of atomic spectroscopy, integrated photonics, and microelectromechanical systems leads the way to the demonstration of microcell-based optical atomic clocks. Here, we report the short-term stability budget of table-top Cs microcell-stabilized lasers based on dual-frequency sub-Doppler spectroscopy (DFSDS). The dependence of the sub-Doppler resonance properties on key experimental parameters is studied. The detection noise budget and absolute phase noise measurements are in good agreement with the measured short-term frequency stability of the laser beatnote, at the level of 1.1 × 10 − 12 τ − 1 / 2 until 100 s, currently limited by the intermodulation effect from a distributed-feedback laser setup. The fractional frequency stability of the laser beatnote at 1 s is about 100 times greater than that of commercial microwave chip-scale atomic clocks and validates interest in the DFSDS approach for the development of high-performance microcell-based optical standards.

Journal of the Optical Society of America B•Sep 20, 2021•30 citations

Short-term stability of a microcell optical reference based on Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5 $\times$ 10$^{-13}$ $τ^{-1/2}$ until 200~s, in good agreement with a phase noise level of $+$ 43 dBrad$^2$/Hz at 1~Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. With still a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

arXiv:2407.00841•Jun 30, 2024•0 citations

Short-term stability of a microcell optical reference based on the Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

Journal of the Optical Society of America B•Nov 22, 2024•14 citations
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.
We report on the characterization of sub-Doppler resonances detected by probing the 6S1/2 - 7P1/2 transition of the Cs atom at 459 nm in a microfabricated vapor cell. The dependence of the sub-Doppler resonance (linewidth, amplitude) on some key experimental parameters, including the laser intensity and the cell temperature, is investigated. These narrow atomic resonances are of interest for high-resolution spectroscopy and instrumentation and may constitute the basis of a high-stability microcell optical standard.
We summarize activities performed at FEMTO-ST Institute and Centrale Lille/IEMN over the last years on the development of microfabricated vapor cells dedicated to atomic clocks, frequency references and sensors. Recent advances on the microcell technology are described. We have demonstrated CPT-based microwave clocks with stability in the low 10−12 range thanks to the implementation of advanced pulsed Ramsey-based interrogation sequences and cells built with low-permeation glass substrates and Al2O3 coatings. We have developed microcell optical frequency references, one based on the two-photon transition of Rb atom at 778 nm and one on saturated absorption of the 6S1/2-7P1/2 transition of Cs atom at 459 nm, with short-term stability levels in the low 10−13 range at 1 s and averaging down in the low 10−14 range after 100 s. Optically pumped magnetometers with sensitivity at the level of 100 fT/√Hz have also been demonstrated. In-progress studies, on both the cell technology and metrology aspects, are also discussed.
Sub-Doppler spectroscopy of the near-UV Cs atom 6S1/2_{1/2}1/2​-7P1/2_{1/2}1/2​ transition in a microfabricated vapor cell
We report on the characterization of sub-Doppler resonances detected by probing the 6S1/2_{1/2}1/2​-7P1/2_{1/2}1/2​ transition of Cs atom at 459 nm in a microfabricated vapor cell. The dependence of the sub-Doppler resonance (linewidth, amplitude) on some key experimental parameters, including the laser intensity and the cell temperature, is investigated. These narrow atomic resonances are of interest for high-resolution spectroscopy, instrumentation, and may constitute the basis of a near-UV microcell optical standard.
The combination of atomic spectroscopy, integrated photonics, and microelectromechanical systems leads the way to the demonstration of microcell-based optical atomic clocks. Here, we report the short-term stability budget of table-top Cs microcell-stabilized lasers based on dual-frequency sub-Doppler spectroscopy (DFSDS). The dependence of the sub-Doppler resonance properties on key experimental parameters is studied. The detection noise budget and absolute phase noise measurements are in good agreement with the measured short-term frequency stability of the laser beatnote, at the level of 1.1 × 10 − 12 τ − 1 / 2 until 100 s, currently limited by the intermodulation effect from a distributed-feedback laser setup. The fractional frequency stability of the laser beatnote at 1 s is about 100 times greater than that of commercial microwave chip-scale atomic clocks and validates interest in the DFSDS approach for the development of high-performance microcell-based optical standards.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5 ×\times× 10−13^{-13}−13 τ−1/2τ^{-1/2}τ−1/2 until 200~s, in good agreement with a phase noise level of +++ 43 dBrad2^22/Hz at 1~Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. With still a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.