Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...

A microfabricated photonic magnetometer

Jan Preusser, Vladislav P. Gerginov, Svenja A. Knappe, John E. Kitching

Published Oct 1, 2008• 16 citations
Publisher

Abstract

An integrated optically-controlled sensor, suitable for remote, high-sensitivity detection of magnetic fields, is presented. The sensor head is free of electrical currents or metal parts, which largely eliminates any spurious fields created by the sensor itself. We demonstrate the operation of the sensor by employing a scheme first published by Bell and Bloom and reach a sensitivity of 2.6 pT/Hz1/2at 30 Hz, limited primarily by the photon shot noise of the detector.

DOI
10.1109/icsens.2008.4716451

Related papers

A microfabricated photonic magnetometer

Jan Preusser, Svenja A. Knappe, Vladislav P. Gerginov +1 more

An integrated optically-controlled sensor, suitable for remote, high-sensitivity detection of magnetic fields is presented. The operation of the sensor both in earth field in a Bell-Bloom type configuration is demonstrated as well as in a spin-exchange relaxation-free mode (SERF) and reach sensitivities better than 500 fT/radicHz at 10 Hz. The design and initial measurements of a small atomic magnetometer that has no electrical connections near the sensor head is presented. The sensor is fabricated by use of methods derived from microelectromechanical (MEMS) systems and integrated with off-the-shelf micro-optical components. Light is coupled through fibers to and from the sensor head for interrogation of the atoms. Heating of the atomic vapor is achieved by a second fiber-coupled laser source, utilizing the absorption properties of the vapor cell.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•10 citations

A Microfabricated High Performance Magnetometer

B. J. Lindseth, Peter D. D. Schwindt, Svenja A. Knappe +4 more

We report the operation of a microfabricated atomic magnetometer using the Mx configuration. A device size of a few millimeters achieves a magnetic field noise limited sensitivity of 5.9 pT/Hz1/2 over a 1-100 Hz bandwidth.

Frontiers in Optics•Jan 1, 2006•0 citations

A microfabricated photonic magnetometer

Jan Preusser, Svenja A. Knappe, John E. Kitching +1 more

We present initial measurements of an atomic magnetometer in which the microfabricated sensor head is coupled to the control system by optical fibers. Because there are no electrical connections, the sensor head is largely non-magnetic, and degradation of the magnetometer performance due to internal magnetic fields is avoided. The sensor head is fabricated by use of methods derived from micro-electromechanical (MEMS) systems and integrated with off-the-shelf micro-optical components. Light is coupled through fibers to and from the sensor head for interrogation of the atoms as well as temperature stabilization of the vapor cell.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•20 citations

Pulsed operation of a miniature scalar optically pumped magnetometer

Vladislav P. Gerginov, Sean Krzyzewski, Svenja A. Knappe

A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.

Journal of the Optical Society of America B•Jun 15, 2017•57 citations

A low-power, high-sensitivity micromachined optical magnetometer

Rahul R. Mhaskar, Svenja A. Knappe, John E. Kitching

We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.

Applied Physics Letters•Dec 10, 2012•172 citations

Continuous High-Sensitivity and High-Bandwidth Atomic Magnetometer

Rujie Li, Fred N. Baynes, Andre Nicholas Luiten +1 more

Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.

Physical Review Applied•Dec 23, 2020•75 citations
An integrated optically-controlled sensor, suitable for remote, high-sensitivity detection of magnetic fields, is presented. The sensor head is free of electrical currents or metal parts, which largely eliminates any spurious fields created by the sensor itself. We demonstrate the operation of the sensor by employing a scheme first published by Bell and Bloom and reach a sensitivity of 2.6 pT/Hz1/2at 30 Hz, limited primarily by the photon shot noise of the detector.
An integrated optically-controlled sensor, suitable for remote, high-sensitivity detection of magnetic fields is presented. The operation of the sensor both in earth field in a Bell-Bloom type configuration is demonstrated as well as in a spin-exchange relaxation-free mode (SERF) and reach sensitivities better than 500 fT/radicHz at 10 Hz. The design and initial measurements of a small atomic magnetometer that has no electrical connections near the sensor head is presented. The sensor is fabricated by use of methods derived from microelectromechanical (MEMS) systems and integrated with off-the-shelf micro-optical components. Light is coupled through fibers to and from the sensor head for interrogation of the atoms. Heating of the atomic vapor is achieved by a second fiber-coupled laser source, utilizing the absorption properties of the vapor cell.
We present initial measurements of an atomic magnetometer in which the microfabricated sensor head is coupled to the control system by optical fibers. Because there are no electrical connections, the sensor head is largely non-magnetic, and degradation of the magnetometer performance due to internal magnetic fields is avoided. The sensor head is fabricated by use of methods derived from micro-electromechanical (MEMS) systems and integrated with off-the-shelf micro-optical components. Light is coupled through fibers to and from the sensor head for interrogation of the atoms as well as temperature stabilization of the vapor cell.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.
Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.