Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

Realization of an Atomic Fountain Using a Novel Launching Method

Junxian Fu, Shuai Chen, Xuzong Chen, Donghai Yang, Yiqiu Wang

Published Oct 10, 2001• 4 citations
Publisher

Abstract

We have realized a cesium atomic fountain using a novel launching method. We have obtained 10 8 atoms in the magneto-optical trap experiment and have studied the temperature and launching height with different laser frequency detuning to the cesium resonance line. A fountain with a height of 1.8 cm and a temperature of 30±10µK was achieved. In comparison with other experiments, we have also discussed the advantages and disadvantages of our method used in the present experiment.

DOI
10.1088/0256-307x/18/11/310

Related papers

Laser-cooled cesium atomic fountain experiment for atomic frequency standard

Jun Umezu, Yasusada Ohta, K. Hukuda +2 more

A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>

Conference proceedings - IEEE Instrumentation/Measurement Technology Conference•Dec 17, 2002•0 citations

Laser cooling and launching performance in a (1,1,1)-geometry atomic fountain

Elizabeth A. Donley, Thomas P. Heavner, J.W. O'Brien +2 more

We have successfully cooled and launched cesium atoms in the (1,1,1) atomic fountain geometry at temperatures as low as 0.8 /spl mu/K. This corresponds to a root-mean-square thermal velocity of 0.7 cm/s, which is two times the photon recoil velocity of 0.35 cm/s. Factors that limit the final temperature are presented in detail.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 18, 2006•5 citations

Update on the development of cesium atomic fountain at NPL, India

Poonam Arora, Ashish Agarwal, Kavindra Pant +2 more

National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.

URSI General Assembly and Scientific Symposium•Aug 1, 2011•0 citations

Work towards an atomic fountain clock at Peking University

Yimin Li, Jidong Hou, Junxian Fu +3 more

Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•0 citations

Experiments and Considerations of Realizing Cold Cesium Atomic 74 cm Fountain

Tianchu Li

The realization of 74 cm fountain of atomic clouds, obtaining fluorescence signal of time of flight with S/N~200, on NIM4# laser cooling - Cs atomic fountain clock is described. The improvements concerning launching - falling - signal detection are introduced, launching parameters listed, the fountain experiments are reported, and some preliminary discussions given.

Jiliang xuebao•Jan 1, 2003•0 citations

Article

Marie-Claude Gagné, J.-S. Boulanger, R J W Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Aug 1, 1998•0 citations
We have realized a cesium atomic fountain using a novel launching method. We have obtained 10 8 atoms in the magneto-optical trap experiment and have studied the temperature and launching height with different laser frequency detuning to the cesium resonance line. A fountain with a height of 1.8 cm and a temperature of 30±10µK was achieved. In comparison with other experiments, we have also discussed the advantages and disadvantages of our method used in the present experiment.
A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>
National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.
Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P