Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

An atomic beam source for fast loading of a magneto-optical trap under high vacuum

Peter D. McDowall, Tzahi Grünzweig, Andrew J. Hilliard, Mikkel F. Andersen

Published May 1, 2012• 9 citations
Publisher

Abstract

We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.

DOI
10.1063/1.4708617

Related papers

Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments

Kevin L. Moore, Thomas Purdy, Kater W. Murch +3 more

We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.

arXiv:physics/0409011•Review of Scientific Instruments•Jan 7, 2005•22 citations

Fast loading of a magneto-optical trap from a pulsed thermal source

József Fortágh, Alexander Grossmann, Theodor W. Hänsch +1 more

We report an efficient method to load atoms into a magneto-optical trap. A resistively heated alkali metal dispenser, which is mounted close to the trapping region, serves as a compact, pulsed source for Rb atoms. The atoms are captured by the magneto-optical trap within less than 3 s at a loading rate of more than 107 atoms per second. The lifetime of the trapped atoms exceeds the filling time by about 30 s.

Journal of Applied Physics•Dec 15, 1998•72 citations

Magneto-optical trap loaded from a low-velocity intense source

Chang Yong Park, Myung Sim Jun, D. Cho

We produced a slow atomic beam of rubidium with a low-velocity intense source (LVIS) and loaded a magneto-optical trap (MOT) in a connected chamber with the beam. The hole for the atomic beam allowed us to keep the MOT chamber at a much lower pressure than that of the LVIS. The LVIS produced an atomic beam with a continuous flux of (4.3±0.4)×109/s and an average velocity of only 11±3 m/s. The MOT captured the atoms with 67±15% efficiency, which was limited by the atomic-beam divergence. The MOT held 6×109 atoms with a typical trap-confinement time of 8 s.

Journal of the Optical Society of America B•Jun 1, 1999•12 citations

Pulsed loading of a magneto-optical trap on an atom chip with fast recovery of ultrahigh vacuum

Vivek Singh, Vibhuti Bhushan Tiwari, A Chaudhary +2 more

Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.

Laser Physics Letters•Dec 19, 2024•0 citations

Low-Velocity Intense Source of Atoms from a Magneto-optical Trap

Zheng‐Tian Lu, Kristan L. Corwin, Michael J. Renn +3 more

We have produced and characterized an intense, slow, and highly collimated atomic beam extracted from a standard vapor cell magneto-optical trap (MOT). The technique used is dramatically simpler than previous methods for producing very cold atomic beams. We have created a 0.6 mm diameter rubidium atomic beam with a continuous flux of $5\ifmmode\times\else\texttimes\fi{}{10}^{9}/\mathrm{s}$ and a pulsed flux 10 times greater. Its longitudinal velocity distribution is centered at 14 m/s with a FWHM of 2.7 m/s. Through an efficient recycling process, 70% of the atoms trapped in the MOT are loaded into the atomic beam.

Physical Review Letters•Oct 14, 1996•269 citations

Direct loading of a Sr magneto-optical trap from a thermal atomic beam

Naohiro Okamoto, Takumi Sato, T. Aoki +1 more

We demonstrate direct loading of a strontium (Sr) magneto-optical trap (MOT) from a thermal atomic beam in a single-chamber vacuum system. The MOT operates without a Zeeman slower, a slowing laser, a two-dimensional MOT, or differential pumping, while the entire system is maintained in the ultra-high-vacuum regime by a single ion pump. At an oven temperature of 395 °C, the MOT captures up to 107 88Sr atoms with a loading rate of 107 atoms s-1, while sustaining a background gas pressure of 1 × 10-9 Torr. At this oven temperature, the MOT lifetime limited by collisions with background gas is ∼5s, with the atom number primarily constrained by light-assisted two-body collisions. Eliminating differential pumping and precooling stages significantly reduces the system's size, weight, and power requirements, providing a robust and practical platform for field-deployable and spaceborne optical lattice clocks, as well as a variety of other applications requiring compact ultracold atom sources.

arXiv:2509.13764•Review of Scientific Instruments•Mar 1, 2026•1 citation
We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.
We produced a slow atomic beam of rubidium with a low-velocity intense source (LVIS) and loaded a magneto-optical trap (MOT) in a connected chamber with the beam. The hole for the atomic beam allowed us to keep the MOT chamber at a much lower pressure than that of the LVIS. The LVIS produced an atomic beam with a continuous flux of (4.3±0.4)×109/s and an average velocity of only 11±3 m/s. The MOT captured the atoms with 67±15% efficiency, which was limited by the atomic-beam divergence. The MOT held 6×109 atoms with a typical trap-confinement time of 8 s.
Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.
We have produced and characterized an intense, slow, and highly collimated atomic beam extracted from a standard vapor cell magneto-optical trap (MOT). The technique used is dramatically simpler than previous methods for producing very cold atomic beams. We have created a 0.6 mm diameter rubidium atomic beam with a continuous flux of $5\ifmmode\times\else\texttimes\fi{}{10}^{9}/\mathrm{s}$ and a pulsed flux 10 times greater. Its longitudinal velocity distribution is centered at 14 m/s with a FWHM of 2.7 m/s. Through an efficient recycling process, 70% of the atoms trapped in the MOT are loaded into the atomic beam.
We demonstrate direct loading of a strontium (Sr) magneto-optical trap (MOT) from a thermal atomic beam in a single-chamber vacuum system. The MOT operates without a Zeeman slower, a slowing laser, a two-dimensional MOT, or differential pumping, while the entire system is maintained in the ultra-high-vacuum regime by a single ion pump. At an oven temperature of 395 °C, the MOT captures up to 107 88Sr atoms with a loading rate of 107 atoms s-1, while sustaining a background gas pressure of 1 × 10-9 Torr. At this oven temperature, the MOT lifetime limited by collisions with background gas is ∼5s, with the atom number primarily constrained by light-assisted two-body collisions. Eliminating differential pumping and precooling stages significantly reduces the system's size, weight, and power requirements, providing a robust and practical platform for field-deployable and spaceborne optical lattice clocks, as well as a variety of other applications requiring compact ultracold atom sources.