arXiv:physics/0409011 · Review of Scientific Instruments

Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments

Kevin L. Moore, Thomas Purdy, Kater W. Murch, Sabrina R. Leslie, Subhadeep Gupta, Dan Stamper-Kurn

Published Jan 7, 2005• 22 citations
arXivHTMLPDF

Abstract

We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.

DOI
10.1063/1.1841852

Related papers

An atomic beam source for fast loading of a magneto-optical trap under high vacuum

Peter D. McDowall, Tzahi Grünzweig, Andrew J. Hilliard +1 more

We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.

Review of Scientific Instruments•May 1, 2012•9 citations

Pulsed loading of a magneto-optical trap on atom chip for fast pressure recovery in ultrahigh vacuum environment

Singh, Vivek, Vibhuti Bhushan Tiwari, A. Chaudhary +2 more

This study presents investigations on pulsed loading of a magneto-optical trap (MOT) on an atom chip in an UHV environment. Using three parallel resistively heated Rb-metal dispensers activated by pulsed current supply, approximately 3.0 $\times$ $10^{7}$ cold $^{87}Rb$ atoms were loaded into the MOT. A current pulse of $\sim$ 24 A with duration of $\sim$ 10 s raised the pressure in the chamber from 2.0 $\times$ $10^{-10}$ Torr to 3.3 $\times$ $10^{-10}$ Torr. Remarkably, the pressure recovery time after switching off the dispensers current was found to be $\sim$ 600 ms, making a significant advancement in achieving fast recovery of UHV environment surrounding the MOT region. This study is very useful for laser cooling and magnetic trapping / evaporative cooling of atoms on atom chip in the same UHV chamber.

arXiv:2403.11458•Mar 18, 2024•0 citations

Pulsed loading of a magneto-optical trap on an atom chip with fast recovery of ultrahigh vacuum

Vivek Singh, Vibhuti Bhushan Tiwari, A Chaudhary +2 more

Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.

Laser Physics Letters•Dec 19, 2024•0 citations

Direct loading of a Sr magneto-optical trap from a thermal atomic beam

Naohiro Okamoto, Takumi Sato, T. Aoki +1 more

We demonstrate direct loading of a strontium (Sr) magneto-optical trap (MOT) from a thermal atomic beam in a single-chamber vacuum system. The MOT operates without a Zeeman slower, a slowing laser, a two-dimensional MOT, or differential pumping, while the entire system is maintained in the ultra-high-vacuum regime by a single ion pump. At an oven temperature of 395 °C, the MOT captures up to 107 88Sr atoms with a loading rate of 107 atoms s-1, while sustaining a background gas pressure of 1 × 10-9 Torr. At this oven temperature, the MOT lifetime limited by collisions with background gas is ∼5s, with the atom number primarily constrained by light-assisted two-body collisions. Eliminating differential pumping and precooling stages significantly reduces the system's size, weight, and power requirements, providing a robust and practical platform for field-deployable and spaceborne optical lattice clocks, as well as a variety of other applications requiring compact ultracold atom sources.

arXiv:2509.13764•Review of Scientific Instruments•Mar 1, 2026•1 citation

Direct loading of Yb atoms into a 3D magneto-optical trap from a dispenser atomic source

Junia Nomura, Tomohiko Momma, Yuki Kojima +4 more

The realization of cold atoms using a compact and low-power-consumption experimental setup is indispensable for cold atom experiments, including optical clocks and quantum simulations. We demonstrate the direct loading of Yb atoms into a 3D magneto-optical trap (MOT) from a dispenser atomic source without using a Zeeman slower. The power consumption of the dispenser was ∼3 W. Spectroscopy of the atomic beam from the dispenser on the 6s2 1S0–6s6p 1P1 Yb transition at 399 nm shows that the flux of the atomic beam reaches 1.4 × 1013 s−1 cm−2. We can load up to 4.1 × 107 atoms into the MOT with slowing and trapping laser powers of 20.3 and 35.0 mW, respectively. The realized cold atom system is reliable and can be adapted for experiments on alkaline earth and other alkaline earth-like atoms.

AIP Advances•Feb 1, 2023•6 citations

Collimated versatile atomic beam source with alkali dispensers

Bochao Wei, Alexandra Crawford, Yorick Andeweg +3 more

Alkali metal dispensers have become an indispensable tool in the production of atomic vapors for magnetometry, alkali vapor cell clocks, and laser cooling experiments. A primary advantage of these dispensers is that they contain alkali metal in an inert form that can be exposed to air without hazard. However, their high temperature of operation (>600 °C) is undesirable for many applications, as it shifts the atomic speed distribution to higher values and presents a radiative heat source that can raise the temperature of its surroundings. For this reason, dispensers are typically not used in line-of-sight applications, such as atomic beam generation. In this work, we present an integrated rubidium dispenser collimating device with a thickness of only 2 mm that produces a beam of atoms traveling primarily in the forward direction. We find that the collimator plate serves to both shield the dispenser's radiation and moderate the velocity of the atomic beam so that the measured longitudinal speed distribution is comparable to that of an ordinary alkali oven at only a slightly elevated temperature of 200 °C. To confirm our theory, we also constructed another compact apparatus consisting of a dispenser and a silicon collimator and the measurements support our conclusion. Our integrated dispenser collimator will particularly be useful in integrated photonics and cavity QED on-chip, where a localized, directed source of Rb vapor in small quantities is needed.

arXiv:2202.07076•Applied Physics Letters•Apr 4, 2022•6 citations
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.
We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.
This study presents investigations on pulsed loading of a magneto-optical trap (MOT) on an atom chip in an UHV environment. Using three parallel resistively heated Rb-metal dispensers activated by pulsed current supply, approximately 3.0 ×\times× 10710^{7}107 cold 87Rb^{87}Rb87Rb atoms were loaded into the MOT. A current pulse of ∼\sim∼ 24 A with duration of ∼\sim∼ 10 s raised the pressure in the chamber from 2.0 ×\times× 10−1010^{-10}10−10 Torr to 3.3 ×\times× 10−1010^{-10}10−10 Torr. Remarkably, the pressure recovery time after switching off the dispensers current was found to be ∼\sim∼ 600 ms, making a significant advancement in achieving fast recovery of UHV environment surrounding the MOT region. This study is very useful for laser cooling and magnetic trapping / evaporative cooling of atoms on atom chip in the same UHV chamber.
Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.
We demonstrate direct loading of a strontium (Sr) magneto-optical trap (MOT) from a thermal atomic beam in a single-chamber vacuum system. The MOT operates without a Zeeman slower, a slowing laser, a two-dimensional MOT, or differential pumping, while the entire system is maintained in the ultra-high-vacuum regime by a single ion pump. At an oven temperature of 395 °C, the MOT captures up to 107 88Sr atoms with a loading rate of 107 atoms s-1, while sustaining a background gas pressure of 1 × 10-9 Torr. At this oven temperature, the MOT lifetime limited by collisions with background gas is ∼5s, with the atom number primarily constrained by light-assisted two-body collisions. Eliminating differential pumping and precooling stages significantly reduces the system's size, weight, and power requirements, providing a robust and practical platform for field-deployable and spaceborne optical lattice clocks, as well as a variety of other applications requiring compact ultracold atom sources.
The realization of cold atoms using a compact and low-power-consumption experimental setup is indispensable for cold atom experiments, including optical clocks and quantum simulations. We demonstrate the direct loading of Yb atoms into a 3D magneto-optical trap (MOT) from a dispenser atomic source without using a Zeeman slower. The power consumption of the dispenser was ∼3 W. Spectroscopy of the atomic beam from the dispenser on the 6s2 1S0–6s6p 1P1 Yb transition at 399 nm shows that the flux of the atomic beam reaches 1.4 × 1013 s−1 cm−2. We can load up to 4.1 × 107 atoms into the MOT with slowing and trapping laser powers of 20.3 and 35.0 mW, respectively. The realized cold atom system is reliable and can be adapted for experiments on alkaline earth and other alkaline earth-like atoms.
Alkali metal dispensers have become an indispensable tool in the production of atomic vapors for magnetometry, alkali vapor cell clocks, and laser cooling experiments. A primary advantage of these dispensers is that they contain alkali metal in an inert form that can be exposed to air without hazard. However, their high temperature of operation (>600 °C) is undesirable for many applications, as it shifts the atomic speed distribution to higher values and presents a radiative heat source that can raise the temperature of its surroundings. For this reason, dispensers are typically not used in line-of-sight applications, such as atomic beam generation. In this work, we present an integrated rubidium dispenser collimating device with a thickness of only 2 mm that produces a beam of atoms traveling primarily in the forward direction. We find that the collimator plate serves to both shield the dispenser's radiation and moderate the velocity of the atomic beam so that the measured longitudinal speed distribution is comparable to that of an ordinary alkali oven at only a slightly elevated temperature of 200 °C. To confirm our theory, we also constructed another compact apparatus consisting of a dispenser and a silicon collimator and the measurements support our conclusion. Our integrated dispenser collimator will particularly be useful in integrated photonics and cavity QED on-chip, where a localized, directed source of Rb vapor in small quantities is needed.