Absolute spectral calibration of an intensified CCD camera using twin beams

Ondřej Haderka, Jan Peřina, Václav Michálek, Martin Hamar

Published Aug 6, 2014• 10 citations
Publisher

Abstract

Twin beams composed of photon pairs are used for absolute determination of quantum detection efficiency of an intensified CCD camera. A method of fitting the experimental photocount statistics with the paired superposition of signal and noise, combined with additional determination of losses in the beams before the detector, is used to reveal the detection efficiencies. The experiment has been performed in several spectral regions defined by the used interference filters. Also, the used twin beams have been reconstructed.

DOI
10.1364/josab.31.0000b1

Related papers

Absolute detector calibration using twin beams

Jan Peřina, Ondřej Haderka, Václav Michálek +1 more

A method for the determination of absolute quantum detection efficiency is suggested based on the measurement of photocount statistics of twin beams. The measured histograms of joint signal-idler photocount statistics allow us to eliminate an additional noise superimposed on an ideal calibration field composed of only photon pairs. This makes the method superior above other approaches presently used. Twin beams are described using a paired variant of quantum superposition of signal and noise.

arXiv:1205.1969•Optics Letters•Jun 16, 2012•44 citations

Photon-number statistics of twin beams: Self-consistent measurement, reconstruction, and properties

Jan Peřina, Ondřej Haderka, Václav Michálek

A method for the determination of photon-number statistics of twin beams using the joint signal-idler photocount statistics obtained by an iCCD camera is described. It also provides absolute quantum detection efficiency of the camera. Using the measured photocount statistics, quasi-distributions of integrated intensities are obtained. They attain negative values occurring in characteristic strips an a consequence of pairing of photons in twin beams.

AIP conference proceedings•Jan 1, 2014•0 citations

Absolute calibration of photon-number-resolving detectors with an analog output using twin beams

Jan Peřina, Ondřej Haderka, Alessia Allevi +1 more

A method for absolute calibration of a photon-number resolving detector producing analog signals as the output is developed using a twin beam. The method gives both analog-to-digital conversion parameters and quantum detection efficiency for the photon fields. Characteristics of the used twin beam are also obtained. A simplified variant of the method applicable to fields with high signal to noise ratios and suitable for more intense twin beams is suggested.

arXiv:1401.6071•Applied Physics Letters•Jan 27, 2014•28 citations

Absolute efficiency estimation of photon-number-resolving detectors using twin beams

A. P. Worsley, Hendrik B. Coldenstrodt-Ronge, Jeff S. Lundeen +5 more

A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brighter twin-beam sources including amplified pulse pumped sources, which increases the relevant signal and provides measurement redundancy, making the calibration more robust.

arXiv:0906.2182•Optics Express•Mar 4, 2009•45 citations

Experimental characterization of multimode photon-subtracted twin beams

Kishore Thapliyal, Jan Peřina, Ondřej Haderka +2 more

States obtained from multimode twin beams by symmetric as well as asymmetric photon subtraction are experimentally investigated. Using the joint photocount distributions measured by an intensified CCD camera, their joint photon-number distributions are reconstructed. Mean photon numbers, Fano factors, and noise-reduction parameters are determined for the group of states reached by subtracting up to four photocounts in each beam. Photon subtraction is monitored using the nonclassicality depths and joint quasidistributions of integrated intensities of the emerging states. The non-Gaussianity of the obtained states is also determined. The states reached by coherent photon subtraction are also analyzed. The investigations represent an important step towards the use of photon-subtracted twin beams in sub-shot-noise metrology and imaging. Published by the American Physical Society 2024

Physical Review Research•Jan 17, 2024•11 citations

Absolute calibration of a charge-coupled device camera with twin beams

Alice Meda, Ivano Ruo Berchera, Ivo Pietro Degiovanni +3 more

We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.

arXiv:1405.1526•Applied Physics Letters•Sep 8, 2014•30 citations
Twin beams composed of photon pairs are used for absolute determination of quantum detection efficiency of an intensified CCD camera. A method of fitting the experimental photocount statistics with the paired superposition of signal and noise, combined with additional determination of losses in the beams before the detector, is used to reveal the detection efficiencies. The experiment has been performed in several spectral regions defined by the used interference filters. Also, the used twin beams have been reconstructed.
A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brighter twin-beam sources including amplified pulse pumped sources, which increases the relevant signal and provides measurement redundancy, making the calibration more robust.
States obtained from multimode twin beams by symmetric as well as asymmetric photon subtraction are experimentally investigated. Using the joint photocount distributions measured by an intensified CCD camera, their joint photon-number distributions are reconstructed. Mean photon numbers, Fano factors, and noise-reduction parameters are determined for the group of states reached by subtracting up to four photocounts in each beam. Photon subtraction is monitored using the nonclassicality depths and joint quasidistributions of integrated intensities of the emerging states. The non-Gaussianity of the obtained states is also determined. The states reached by coherent photon subtraction are also analyzed. The investigations represent an important step towards the use of photon-subtracted twin beams in sub-shot-noise metrology and imaging. Published by the American Physical Society 2024
We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.