arXiv:1401.6071 · Applied Physics Letters

Absolute calibration of photon-number-resolving detectors with an analog output using twin beams

Jan Peřina, Ondřej Haderka, Alessia Allevi, Maria Bondani

Published Jan 27, 2014• 28 citations
arXivHTMLPDF

Abstract

A method for absolute calibration of a photon-number resolving detector producing analog signals as the output is developed using a twin beam. The method gives both analog-to-digital conversion parameters and quantum detection efficiency for the photon fields. Characteristics of the used twin beam are also obtained. A simplified variant of the method applicable to fields with high signal to noise ratios and suitable for more intense twin beams is suggested.

DOI
10.1063/1.4863433

Related papers

Absolute detector calibration using twin beams

Jan Peřina, Ondřej Haderka, Václav Michálek +1 more

A method for the determination of absolute quantum detection efficiency is suggested based on the measurement of photocount statistics of twin beams. The measured histograms of joint signal-idler photocount statistics allow us to eliminate an additional noise superimposed on an ideal calibration field composed of only photon pairs. This makes the method superior above other approaches presently used. Twin beams are described using a paired variant of quantum superposition of signal and noise.

arXiv:1205.1969•Optics Letters•Jun 16, 2012•44 citations

Absolute efficiency estimation of photon-number-resolving detectors using twin beams

A. P. Worsley, Hendrik B. Coldenstrodt-Ronge, Jeff S. Lundeen +5 more

A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brighter twin-beam sources including amplified pulse pumped sources, which increases the relevant signal and provides measurement redundancy, making the calibration more robust.

arXiv:0906.2182•Optics Express•Mar 4, 2009•45 citations

Absolute spectral calibration of an intensified CCD camera using twin beams

Ondřej Haderka, Jan Peřina, Václav Michálek +1 more

Twin beams composed of photon pairs are used for absolute determination of quantum detection efficiency of an intensified CCD camera. A method of fitting the experimental photocount statistics with the paired superposition of signal and noise, combined with additional determination of losses in the beams before the detector, is used to reveal the detection efficiencies. The experiment has been performed in several spectral regions defined by the used interference filters. Also, the used twin beams have been reconstructed.

Journal of the Optical Society of America B•Aug 6, 2014•10 citations

Absolute self-calibration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion

Ling-An Wu, Xi-Hao Chen, Yanhua Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 31, 2006•0 citations

Absolute self-calib ration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion - art. no. 630505

La Wu, Xiangdong Chen, YH Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

•Jan 1, 2006•0 citations

Absolute calibration of photodiodes with bright twin beams

Alberto M. Marino, Paul D. Lett

We present a scheme based on the use of bright entangled twin beams for the calibration of analog photodiodes, providing an extension of the schemes for calibrating photon-counting detectors with photon pairs. Previous proposals for the calibration of analog photodiodes with entangled beams are based on a stimulated parametric process operating in the low-gain regime. We start by showing that in those proposals it is necessary to know the exact value of the gain as any error in estimating it will lead to an error in the calibration of the quantum efficiency. We then introduce a technique that is independent of the gain, thus eliminating the uncertainty introduced from errors in estimating the gain or experimental fluctuations of parameters that affect the gain. A proof of principle implementation of this technique using bright twin beams obtained from a four-wave mixing process in rubidium vapor shows its viability for the calibration of analog photodiodes.

Journal of Modern Optics•Oct 15, 2010•16 citations
A method for absolute calibration of a photon-number resolving detector producing analog signals as the output is developed using a twin beam. The method gives both analog-to-digital conversion parameters and quantum detection efficiency for the photon fields. Characteristics of the used twin beam are also obtained. A simplified variant of the method applicable to fields with high signal to noise ratios and suitable for more intense twin beams is suggested.
A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brighter twin-beam sources including amplified pulse pumped sources, which increases the relevant signal and provides measurement redundancy, making the calibration more robust.
Twin beams composed of photon pairs are used for absolute determination of quantum detection efficiency of an intensified CCD camera. A method of fitting the experimental photocount statistics with the paired superposition of signal and noise, combined with additional determination of losses in the beams before the detector, is used to reveal the detection efficiencies. The experiment has been performed in several spectral regions defined by the used interference filters. Also, the used twin beams have been reconstructed.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.
We present a scheme based on the use of bright entangled twin beams for the calibration of analog photodiodes, providing an extension of the schemes for calibrating photon-counting detectors with photon pairs. Previous proposals for the calibration of analog photodiodes with entangled beams are based on a stimulated parametric process operating in the low-gain regime. We start by showing that in those proposals it is necessary to know the exact value of the gain as any error in estimating it will lead to an error in the calibration of the quantum efficiency. We then introduce a technique that is independent of the gain, thus eliminating the uncertainty introduced from errors in estimating the gain or experimental fluctuations of parameters that affect the gain. A proof of principle implementation of this technique using bright twin beams obtained from a four-wave mixing process in rubidium vapor shows its viability for the calibration of analog photodiodes.