Absolute calibration of a charge-coupled device camera with twin beams

Alice Meda, Ivano Ruo Berchera, Ivo Pietro Degiovanni, G. Brida, Maria Luisa Rastello, Marco Genovese

Published Sep 8, 2014• 30 citations
arXivHTMLPDF

Abstract

We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.

DOI
10.1063/1.4895665

Related papers

Detection of multimode spatial correlation in PDC and application to the absolute calibration of a CCD camera

G. Brida, Ivo Pietro Degiovanni, Marco Genovese +2 more

We propose and demonstrate experimentally a new method based on the spatial entanglement for the absolute calibration of analog detectors. The idea consists on measuring the sub-shot-noise intensity correlation between two branches of parametric down conversion, containing many pairwise correlated spatial modes. We calibrate a scientific CCD camera and a preliminary evaluation of the uncertainty indicates the metrological interest of the method.

arXiv:1005.2937•Optics Express•Sep 14, 2010•73 citations

LDPC Coding for QKD at Higher Photon Flux Levels Based on Spatial Entanglement of Twin beams in PDC

F. Daneshgaran, M. Mondin, Inam Bari

Twin beams generated by Parametric Down Conversion (PDC) exhibit quantum correlations that has been effectively used as a tool for many applications including calibration of single photon detectors. By now, detection of multi-mode spatial correlations is a mature field and in principle, only depends on the transmission and detection efficiency of the devices and the channel. In [2, 4, 5], the authors utilized their know-how on almost perfect selection of modes of pairwise correlated entangled beams and the optimization of the noise reduction to below the shot-noise level, for absolute calibration of Charge Coupled Device (CCD) cameras. The same basic principle is currently being considered by the same authors for possible use in Quantum Key Distribution (QKD) [3, 1]. The main advantage in such an approach would be the ability to work with much higher photon fluxes than that of a single photon regime that is theoretically required for discrete variable QKD applications (in practice, very weak laser pulses with mean photon count below one are used).The natural setup of quantization of CCD detection area and subsequent measurement of the correlation statistic needed to detect the presence of the eavesdropper Eve, leads to a QKD channel model that is a Discrete Memoryless Channel (DMC) with a number of inputs and outputs that can be more than two (i.e., the channel is a multi-level DMC). This paper investigates the use of Low Density Parity Check (LDPC) codes for information reconciliation on the effective parallel channels associated with the multi-level DMC. The performance of such codes are shown to be close to the theoretical limits

Journal of Physics Conference Series•Apr 9, 2014•1 citation

Absolute calibration of an EMCCD camera by quantum correlation, linking photon counting to the analog regime

Alessio Avella, Ivano Ruo Berchera, Ivo Pietro Degiovanni +2 more

We show how the same setup and procedure, exploiting spatially multimode quantum correlations, allows the absolute calibration of an electron-multiplying charge-coupled (EMCCD) camera from the analog regime down to the single-photon-counting level, just by adjusting the brightness of the quantum source. At the single-photon level, an EMCCD can be operated as an on-off detector, where quantum efficiency depends on the discriminating threshold. We develop a simple model to explain the connection of the two different regimes demonstrating that the efficiency estimated in the analog (bright) regime allows us to accurately predict the detector behavior in the photocounting regime and vice versa. This work establishes a bridge between two regions of the optical measurements that up to now have been based on completely different standards, detectors, and measurement techniques.

arXiv:1601.07379•Optics Letters•Apr 12, 2016•59 citations

CCD-based detection of quantum spatial correlation of twin beams for high-sensitivity imaging

Ottavia Jedrkiewicz, Gabriel Molina‐Terriza, E. Brambilla +4 more

We review and compare the results of quantum spatial correlation measurements in parametric down-conversion in the high-gain pulsed regime, with preliminary measurements performed in the low-gain cw-pumped regime. The diagnostics is based on a high quantum efficiency CCD camera, and in the second case the radiation pattern is recorded after temporal integration of the "single-photon" spatial distribution. The effect of the detected number of temporal modes on the accessibility of the sub-shot noise regime is discussed, together with the identification of suitable regimes for weak image detection.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 11, 2007•0 citations

Absolute spectral calibration of an intensified CCD camera using twin beams

Ondřej Haderka, Jan Peřina, Václav Michálek +1 more

Twin beams composed of photon pairs are used for absolute determination of quantum detection efficiency of an intensified CCD camera. A method of fitting the experimental photocount statistics with the paired superposition of signal and noise, combined with additional determination of losses in the beams before the detector, is used to reveal the detection efficiencies. The experiment has been performed in several spectral regions defined by the used interference filters. Also, the used twin beams have been reconstructed.

Journal of the Optical Society of America B•Aug 6, 2014•10 citations

Absolute calibration of an analog InSb detector based on multimode spatial correlation of correlated photons

Xia Maopeng, Jianjun Li, Gao Dongyang +4 more

Absolute calibration can be realized by means of correlation photon which is generated by the parametric down conversion. The main difficulty lies in obtaining correlation information about photon flux when this method is applied to analog detector calibration process. A novel method of processing the photocurrent on the basis of detecting multimode spatial correlation is proposed. By converting the charge quantity contained in the photocurrent detected in a certain time interval into the photon counting, and by using double channels balance detection and measuring mean photon counts of each model to correct the dual channels fluctuations, the high accuracy calibration of quantum efficiency can be achieved. The photon fluxes of two channels are balanced by inserting an adjustable attenuator in one optical path. The cross section of pumping beam is comparable to the detection area to ensure three-wave colinearity, and the coherent area of the correlation photons is obtained by measuring pump beam waist and lens focus length. With the known detection area, coherence time and coherence area, the average photon number of each mode is computed. This process should be performed under the average photon number of each mode as a reference which could be used for the proportional scaling of equivalent photons of two channels. Based on this new approach, the absolute power responsivity of an InSb detector is calibrated at 3390 nm with correlated photon pairs at 631 and 3390 nm. The calibration procedure and experiments are described and the uncertainty of this method is analyzed. The results show a relative combination uncertainty of about 7.785% for this calibration method, which agrees well with the result independently obtained in the national photoelectronic metrology laboratory within a relative difference of about 3.6%. This result verifies that the quantum efficiency of an analog detector can be calibrated by the correlated photon method, which has potential applications in highly accurate radiometric calibration without external standards.

Acta Physica Sinica•Jan 1, 2015•1 citation
We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.
Twin beams generated by Parametric Down Conversion (PDC) exhibit quantum correlations that has been effectively used as a tool for many applications including calibration of single photon detectors. By now, detection of multi-mode spatial correlations is a mature field and in principle, only depends on the transmission and detection efficiency of the devices and the channel. In [2, 4, 5], the authors utilized their know-how on almost perfect selection of modes of pairwise correlated entangled beams and the optimization of the noise reduction to below the shot-noise level, for absolute calibration of Charge Coupled Device (CCD) cameras. The same basic principle is currently being considered by the same authors for possible use in Quantum Key Distribution (QKD) [3, 1]. The main advantage in such an approach would be the ability to work with much higher photon fluxes than that of a single photon regime that is theoretically required for discrete variable QKD applications (in practice, very weak laser pulses with mean photon count below one are used).The natural setup of quantization of CCD detection area and subsequent measurement of the correlation statistic needed to detect the presence of the eavesdropper Eve, leads to a QKD channel model that is a Discrete Memoryless Channel (DMC) with a number of inputs and outputs that can be more than two (i.e., the channel is a multi-level DMC). This paper investigates the use of Low Density Parity Check (LDPC) codes for information reconciliation on the effective parallel channels associated with the multi-level DMC. The performance of such codes are shown to be close to the theoretical limits
We show how the same setup and procedure, exploiting spatially multimode quantum correlations, allows the absolute calibration of an electron-multiplying charge-coupled (EMCCD) camera from the analog regime down to the single-photon-counting level, just by adjusting the brightness of the quantum source. At the single-photon level, an EMCCD can be operated as an on-off detector, where quantum efficiency depends on the discriminating threshold. We develop a simple model to explain the connection of the two different regimes demonstrating that the efficiency estimated in the analog (bright) regime allows us to accurately predict the detector behavior in the photocounting regime and vice versa. This work establishes a bridge between two regions of the optical measurements that up to now have been based on completely different standards, detectors, and measurement techniques.
We review and compare the results of quantum spatial correlation measurements in parametric down-conversion in the high-gain pulsed regime, with preliminary measurements performed in the low-gain cw-pumped regime. The diagnostics is based on a high quantum efficiency CCD camera, and in the second case the radiation pattern is recorded after temporal integration of the "single-photon" spatial distribution. The effect of the detected number of temporal modes on the accessibility of the sub-shot noise regime is discussed, together with the identification of suitable regimes for weak image detection.
Twin beams composed of photon pairs are used for absolute determination of quantum detection efficiency of an intensified CCD camera. A method of fitting the experimental photocount statistics with the paired superposition of signal and noise, combined with additional determination of losses in the beams before the detector, is used to reveal the detection efficiencies. The experiment has been performed in several spectral regions defined by the used interference filters. Also, the used twin beams have been reconstructed.
Absolute calibration can be realized by means of correlation photon which is generated by the parametric down conversion. The main difficulty lies in obtaining correlation information about photon flux when this method is applied to analog detector calibration process. A novel method of processing the photocurrent on the basis of detecting multimode spatial correlation is proposed. By converting the charge quantity contained in the photocurrent detected in a certain time interval into the photon counting, and by using double channels balance detection and measuring mean photon counts of each model to correct the dual channels fluctuations, the high accuracy calibration of quantum efficiency can be achieved. The photon fluxes of two channels are balanced by inserting an adjustable attenuator in one optical path. The cross section of pumping beam is comparable to the detection area to ensure three-wave colinearity, and the coherent area of the correlation photons is obtained by measuring pump beam waist and lens focus length. With the known detection area, coherence time and coherence area, the average photon number of each mode is computed. This process should be performed under the average photon number of each mode as a reference which could be used for the proportional scaling of equivalent photons of two channels. Based on this new approach, the absolute power responsivity of an InSb detector is calibrated at 3390 nm with correlated photon pairs at 631 and 3390 nm. The calibration procedure and experiments are described and the uncertainty of this method is analyzed. The results show a relative combination uncertainty of about 7.785% for this calibration method, which agrees well with the result independently obtained in the national photoelectronic metrology laboratory within a relative difference of about 3.6%. This result verifies that the quantum efficiency of an analog detector can be calibrated by the correlated photon method, which has potential applications in highly accurate radiometric calibration without external standards.